Experimental Research on Data Synchronous Acquisition Method of Subsidence Monitoring in Submarine Gas Hydrate Mining Area

The data synchronous acquisition is crucial to the seafloor subsidence monitoring system for gas hydrate mining areas based on microelectromechanical sensors (MEMS). Because the independent and high-precision time reference sources on land cannot be used on the seafloor, especially in the deep sea,...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Jiawang, Cao, Chen, Ge, Yongqiang, Zhu, Huangchao, Xu, Chunying, Sheng, Yan, Tian, Lieyu, Zhang, Hanquan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6806067/
https://www.ncbi.nlm.nih.gov/pubmed/31590421
http://dx.doi.org/10.3390/s19194319
Descripción
Sumario:The data synchronous acquisition is crucial to the seafloor subsidence monitoring system for gas hydrate mining areas based on microelectromechanical sensors (MEMS). Because the independent and high-precision time reference sources on land cannot be used on the seafloor, especially in the deep sea, a relative time synchronization method based on input/output (I/O) and controller area network (CAN) bus was proposed to realize the internal time synchronization of the system. To demonstrate the feasibility of the proposed method, tests including the deformation test of the MEMS sensor array under high pressure, synchronous accuracy test, and landslide and collapse simulation tests were carried out. The synchronization method was performed once every 24 h, and the time drift was reduced to 0.38 ms from more than 30 ms, demonstrating that method can achieve consistent internal time of the system. The method does not require additional hardware devices and has adjustable accuracy.