Cargando…

New Single-Layered Paper-Based Microfluidic Devices for the Analysis of Nitrite and Glucose Built via Deposition of Adhesive Tape

A simple, low-cost technique has been developed for the rapid fabrication of single-layered paper-based microfluidic devices (μPADs). This technique, for the first time, made use of the deposition of patterned adhesive tape into the filter paper to construct hydrophobic barriers, with the help of to...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Peng, Deng, Muhan, Yang, Yi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6806245/
https://www.ncbi.nlm.nih.gov/pubmed/31546594
http://dx.doi.org/10.3390/s19194082
_version_ 1783461585406132224
author Yu, Peng
Deng, Muhan
Yang, Yi
author_facet Yu, Peng
Deng, Muhan
Yang, Yi
author_sort Yu, Peng
collection PubMed
description A simple, low-cost technique has been developed for the rapid fabrication of single-layered paper-based microfluidic devices (μPADs). This technique, for the first time, made use of the deposition of patterned adhesive tape into the filter paper to construct hydrophobic barriers, with the help of toluene. Unlike other reported multi-layered μPADs that merely made use of adhesive tape as a separate layer for sealing or fluid flow controlling, the patterned adhesive tape was simultaneously dissolved and penetrated into the filter paper, which resulted in the successful transfer of the pattern from the tape to the filter paper. To demonstrate the effectiveness of this approach, nitrite and glucose were individually measured; detection limits as low as 0.015 ± 0.004 mM and 0.022 ± 0.006 mM were reported for nitrite and glucose, respectively. Multiplexed analysis of both analytes was also carried out with respective detection limits of 0.048 ± 0.005 mM and 0.025 ± 0.006 mM for nitrite and glucose. The application of the method was demonstrated by measuring nitrite and glucose in spiked artificial urine samples and satisfied recovery results were obtained.
format Online
Article
Text
id pubmed-6806245
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-68062452019-11-07 New Single-Layered Paper-Based Microfluidic Devices for the Analysis of Nitrite and Glucose Built via Deposition of Adhesive Tape Yu, Peng Deng, Muhan Yang, Yi Sensors (Basel) Article A simple, low-cost technique has been developed for the rapid fabrication of single-layered paper-based microfluidic devices (μPADs). This technique, for the first time, made use of the deposition of patterned adhesive tape into the filter paper to construct hydrophobic barriers, with the help of toluene. Unlike other reported multi-layered μPADs that merely made use of adhesive tape as a separate layer for sealing or fluid flow controlling, the patterned adhesive tape was simultaneously dissolved and penetrated into the filter paper, which resulted in the successful transfer of the pattern from the tape to the filter paper. To demonstrate the effectiveness of this approach, nitrite and glucose were individually measured; detection limits as low as 0.015 ± 0.004 mM and 0.022 ± 0.006 mM were reported for nitrite and glucose, respectively. Multiplexed analysis of both analytes was also carried out with respective detection limits of 0.048 ± 0.005 mM and 0.025 ± 0.006 mM for nitrite and glucose. The application of the method was demonstrated by measuring nitrite and glucose in spiked artificial urine samples and satisfied recovery results were obtained. MDPI 2019-09-21 /pmc/articles/PMC6806245/ /pubmed/31546594 http://dx.doi.org/10.3390/s19194082 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yu, Peng
Deng, Muhan
Yang, Yi
New Single-Layered Paper-Based Microfluidic Devices for the Analysis of Nitrite and Glucose Built via Deposition of Adhesive Tape
title New Single-Layered Paper-Based Microfluidic Devices for the Analysis of Nitrite and Glucose Built via Deposition of Adhesive Tape
title_full New Single-Layered Paper-Based Microfluidic Devices for the Analysis of Nitrite and Glucose Built via Deposition of Adhesive Tape
title_fullStr New Single-Layered Paper-Based Microfluidic Devices for the Analysis of Nitrite and Glucose Built via Deposition of Adhesive Tape
title_full_unstemmed New Single-Layered Paper-Based Microfluidic Devices for the Analysis of Nitrite and Glucose Built via Deposition of Adhesive Tape
title_short New Single-Layered Paper-Based Microfluidic Devices for the Analysis of Nitrite and Glucose Built via Deposition of Adhesive Tape
title_sort new single-layered paper-based microfluidic devices for the analysis of nitrite and glucose built via deposition of adhesive tape
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6806245/
https://www.ncbi.nlm.nih.gov/pubmed/31546594
http://dx.doi.org/10.3390/s19194082
work_keys_str_mv AT yupeng newsinglelayeredpaperbasedmicrofluidicdevicesfortheanalysisofnitriteandglucosebuiltviadepositionofadhesivetape
AT dengmuhan newsinglelayeredpaperbasedmicrofluidicdevicesfortheanalysisofnitriteandglucosebuiltviadepositionofadhesivetape
AT yangyi newsinglelayeredpaperbasedmicrofluidicdevicesfortheanalysisofnitriteandglucosebuiltviadepositionofadhesivetape