Impact of intrafraction prostate motion on clinical target coverage in proton therapy: A simulation study of dosimetric differences in two delivery techniques
PURPOSE: To investigate the dosimetric impact of prostate intrafraction motion on proton double‐scattering (DS) and uniform scanning (US) treatments using electromagnetic transponder‐based prostate tracking data in simulated treatment deliveries. METHODS: In proton DS delivery, the spread‐out Bragg...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6806470/ https://www.ncbi.nlm.nih.gov/pubmed/31478341 http://dx.doi.org/10.1002/acm2.12714 |
_version_ | 1783461634175401984 |
---|---|
author | Su, Zhong Slopsema, Roelf Flampouri, Stella Li, Zuofeng |
author_facet | Su, Zhong Slopsema, Roelf Flampouri, Stella Li, Zuofeng |
author_sort | Su, Zhong |
collection | PubMed |
description | PURPOSE: To investigate the dosimetric impact of prostate intrafraction motion on proton double‐scattering (DS) and uniform scanning (US) treatments using electromagnetic transponder‐based prostate tracking data in simulated treatment deliveries. METHODS: In proton DS delivery, the spread‐out Bragg peak (SOBP) is created almost instantaneously by the constant rotation of the range modulator. US, however, delivers each entire energy layer of the SOBP sequentially from distal to proximal direction in time, which can interplay with prostate intrafraction motion. This spatiotemporal interplay during proton treatment was simulated to evaluate its dosimetric impact. Prostate clinical target volume (CTV) dose was obtained by moving CTV through dose matrices of the energy layers according to prostate‐motion traces. Fourteen prostate intrafraction motion traces of each of 17 prostate patients were used in the simulated treatment deliveries. Both single fraction dose‐volume histograms (DVHs) and fraction‐cumulative DVHs were obtained for both 2 Gy per fraction and 7.25 Gy per fraction stereotactic body radiotherapy (SBRT). RESULTS: The simulation results indicated that CTV dose degradation depends on the magnitude and direction of prostate intrafraction motion and is patient specific. For some individual fractions, prescription dose coverage decreased in both US and DS treatments, and hot and cold spots inside the CTV were observed in the US results. However, fraction‐cumulative CTV dose coverage showed much reduced dose degradation for both DS and US treatments for both 2 Gy per fraction and SBRT simulations. CONCLUSIONS: This study indicated that CTV dose inhomogeneity may exist for some patients with severe prostate intrafraction motion during US treatments. However, there are no statistically significant dose differences between DS and US treatment simulations. Cumulative dose of multiple‐fractions significantly reduced dose uncertainties. |
format | Online Article Text |
id | pubmed-6806470 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-68064702019-10-28 Impact of intrafraction prostate motion on clinical target coverage in proton therapy: A simulation study of dosimetric differences in two delivery techniques Su, Zhong Slopsema, Roelf Flampouri, Stella Li, Zuofeng J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: To investigate the dosimetric impact of prostate intrafraction motion on proton double‐scattering (DS) and uniform scanning (US) treatments using electromagnetic transponder‐based prostate tracking data in simulated treatment deliveries. METHODS: In proton DS delivery, the spread‐out Bragg peak (SOBP) is created almost instantaneously by the constant rotation of the range modulator. US, however, delivers each entire energy layer of the SOBP sequentially from distal to proximal direction in time, which can interplay with prostate intrafraction motion. This spatiotemporal interplay during proton treatment was simulated to evaluate its dosimetric impact. Prostate clinical target volume (CTV) dose was obtained by moving CTV through dose matrices of the energy layers according to prostate‐motion traces. Fourteen prostate intrafraction motion traces of each of 17 prostate patients were used in the simulated treatment deliveries. Both single fraction dose‐volume histograms (DVHs) and fraction‐cumulative DVHs were obtained for both 2 Gy per fraction and 7.25 Gy per fraction stereotactic body radiotherapy (SBRT). RESULTS: The simulation results indicated that CTV dose degradation depends on the magnitude and direction of prostate intrafraction motion and is patient specific. For some individual fractions, prescription dose coverage decreased in both US and DS treatments, and hot and cold spots inside the CTV were observed in the US results. However, fraction‐cumulative CTV dose coverage showed much reduced dose degradation for both DS and US treatments for both 2 Gy per fraction and SBRT simulations. CONCLUSIONS: This study indicated that CTV dose inhomogeneity may exist for some patients with severe prostate intrafraction motion during US treatments. However, there are no statistically significant dose differences between DS and US treatment simulations. Cumulative dose of multiple‐fractions significantly reduced dose uncertainties. John Wiley and Sons Inc. 2019-09-03 /pmc/articles/PMC6806470/ /pubmed/31478341 http://dx.doi.org/10.1002/acm2.12714 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Su, Zhong Slopsema, Roelf Flampouri, Stella Li, Zuofeng Impact of intrafraction prostate motion on clinical target coverage in proton therapy: A simulation study of dosimetric differences in two delivery techniques |
title | Impact of intrafraction prostate motion on clinical target coverage in proton therapy: A simulation study of dosimetric differences in two delivery techniques |
title_full | Impact of intrafraction prostate motion on clinical target coverage in proton therapy: A simulation study of dosimetric differences in two delivery techniques |
title_fullStr | Impact of intrafraction prostate motion on clinical target coverage in proton therapy: A simulation study of dosimetric differences in two delivery techniques |
title_full_unstemmed | Impact of intrafraction prostate motion on clinical target coverage in proton therapy: A simulation study of dosimetric differences in two delivery techniques |
title_short | Impact of intrafraction prostate motion on clinical target coverage in proton therapy: A simulation study of dosimetric differences in two delivery techniques |
title_sort | impact of intrafraction prostate motion on clinical target coverage in proton therapy: a simulation study of dosimetric differences in two delivery techniques |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6806470/ https://www.ncbi.nlm.nih.gov/pubmed/31478341 http://dx.doi.org/10.1002/acm2.12714 |
work_keys_str_mv | AT suzhong impactofintrafractionprostatemotiononclinicaltargetcoverageinprotontherapyasimulationstudyofdosimetricdifferencesintwodeliverytechniques AT slopsemaroelf impactofintrafractionprostatemotiononclinicaltargetcoverageinprotontherapyasimulationstudyofdosimetricdifferencesintwodeliverytechniques AT flampouristella impactofintrafractionprostatemotiononclinicaltargetcoverageinprotontherapyasimulationstudyofdosimetricdifferencesintwodeliverytechniques AT lizuofeng impactofintrafractionprostatemotiononclinicaltargetcoverageinprotontherapyasimulationstudyofdosimetricdifferencesintwodeliverytechniques |