Cargando…

Highly Sensitive and Full Range Detectable Humidity Sensor using PEDOT:PSS, Methyl Red and Graphene Oxide Materials

Single transducer with humidity sensing materials has limitations in both range and sensitivity, which cannot be used to detect the full range of humidity with consistent sensitivity. To enlarge range and improve sensitivity in the all range relative humidity (RH), we propose a highly sensitive and...

Descripción completa

Detalles Bibliográficos
Autores principales: Hassan, Gul, Sajid, Memoon, Choi, Changhwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6811546/
https://www.ncbi.nlm.nih.gov/pubmed/31645634
http://dx.doi.org/10.1038/s41598-019-51712-w
_version_ 1783462485635891200
author Hassan, Gul
Sajid, Memoon
Choi, Changhwan
author_facet Hassan, Gul
Sajid, Memoon
Choi, Changhwan
author_sort Hassan, Gul
collection PubMed
description Single transducer with humidity sensing materials has limitations in both range and sensitivity, which cannot be used to detect the full range of humidity with consistent sensitivity. To enlarge range and improve sensitivity in the all range relative humidity (RH), we propose a highly sensitive and full range detectable humidity sensor based on multiple inter-digital transducer (IDT) electrodes connected in series with poly(3,4-ethylenedioxythiophene) doped poly (styrene sulfonate) anions (PEDOT: PSS), C(15)H(15)N(3)O(2) (Methyl Red), and graphene oxide (GO) thin films as the active sensing materials. The humidity sensor with single active material has a limit in the detecting ranges, where the GO, PEDOT: PSS, and Methyl Red materials have sensing responses of 0 to 78% RH, 30 to 75% RH, and 25 to 100% RH, respectively. However, a humidity sensor using combined three active materials can respond to much wider range of RH with high sensitivity, where the IDTs and the active regions were prepared using ink-jet printing and spin coating, respectively. This proposed sensor can detect a full range of 0% RH to 100% RH. The response and recovery times are 1 sec and 3.5 sec, respectively. Our single sensing device using multiple IDTs connected different active materials in series can overcome the limitations of single transducer based sensor for the high performance sensor applications.
format Online
Article
Text
id pubmed-6811546
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-68115462019-10-25 Highly Sensitive and Full Range Detectable Humidity Sensor using PEDOT:PSS, Methyl Red and Graphene Oxide Materials Hassan, Gul Sajid, Memoon Choi, Changhwan Sci Rep Article Single transducer with humidity sensing materials has limitations in both range and sensitivity, which cannot be used to detect the full range of humidity with consistent sensitivity. To enlarge range and improve sensitivity in the all range relative humidity (RH), we propose a highly sensitive and full range detectable humidity sensor based on multiple inter-digital transducer (IDT) electrodes connected in series with poly(3,4-ethylenedioxythiophene) doped poly (styrene sulfonate) anions (PEDOT: PSS), C(15)H(15)N(3)O(2) (Methyl Red), and graphene oxide (GO) thin films as the active sensing materials. The humidity sensor with single active material has a limit in the detecting ranges, where the GO, PEDOT: PSS, and Methyl Red materials have sensing responses of 0 to 78% RH, 30 to 75% RH, and 25 to 100% RH, respectively. However, a humidity sensor using combined three active materials can respond to much wider range of RH with high sensitivity, where the IDTs and the active regions were prepared using ink-jet printing and spin coating, respectively. This proposed sensor can detect a full range of 0% RH to 100% RH. The response and recovery times are 1 sec and 3.5 sec, respectively. Our single sensing device using multiple IDTs connected different active materials in series can overcome the limitations of single transducer based sensor for the high performance sensor applications. Nature Publishing Group UK 2019-10-23 /pmc/articles/PMC6811546/ /pubmed/31645634 http://dx.doi.org/10.1038/s41598-019-51712-w Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Hassan, Gul
Sajid, Memoon
Choi, Changhwan
Highly Sensitive and Full Range Detectable Humidity Sensor using PEDOT:PSS, Methyl Red and Graphene Oxide Materials
title Highly Sensitive and Full Range Detectable Humidity Sensor using PEDOT:PSS, Methyl Red and Graphene Oxide Materials
title_full Highly Sensitive and Full Range Detectable Humidity Sensor using PEDOT:PSS, Methyl Red and Graphene Oxide Materials
title_fullStr Highly Sensitive and Full Range Detectable Humidity Sensor using PEDOT:PSS, Methyl Red and Graphene Oxide Materials
title_full_unstemmed Highly Sensitive and Full Range Detectable Humidity Sensor using PEDOT:PSS, Methyl Red and Graphene Oxide Materials
title_short Highly Sensitive and Full Range Detectable Humidity Sensor using PEDOT:PSS, Methyl Red and Graphene Oxide Materials
title_sort highly sensitive and full range detectable humidity sensor using pedot:pss, methyl red and graphene oxide materials
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6811546/
https://www.ncbi.nlm.nih.gov/pubmed/31645634
http://dx.doi.org/10.1038/s41598-019-51712-w
work_keys_str_mv AT hassangul highlysensitiveandfullrangedetectablehumiditysensorusingpedotpssmethylredandgrapheneoxidematerials
AT sajidmemoon highlysensitiveandfullrangedetectablehumiditysensorusingpedotpssmethylredandgrapheneoxidematerials
AT choichanghwan highlysensitiveandfullrangedetectablehumiditysensorusingpedotpssmethylredandgrapheneoxidematerials