Cargando…
Data from wearable wireless instrumentation device taken during simulated CPR with and without intentional error toward a quality feedback device
Data of Cardiopulmonary Resuscitation performed on a mannequin was collected via wearable instrumentation (using the MYO device). The data were collected for both “good” CPR and for performance of CPR with common errors introduced intentionally for this study. The data are labelled according to the...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6811914/ https://www.ncbi.nlm.nih.gov/pubmed/31667218 http://dx.doi.org/10.1016/j.dib.2019.104400 |
_version_ | 1783462560569229312 |
---|---|
author | Pantanowitz, Adam Ward, Sarah R. Scott, Bronwyn C. Rubin, David M. |
author_facet | Pantanowitz, Adam Ward, Sarah R. Scott, Bronwyn C. Rubin, David M. |
author_sort | Pantanowitz, Adam |
collection | PubMed |
description | Data of Cardiopulmonary Resuscitation performed on a mannequin was collected via wearable instrumentation (using the MYO device). The data were collected for both “good” CPR and for performance of CPR with common errors introduced intentionally for this study. The data are labelled according to the error, and contain a variety of derived measurements. Data collected were used toward “Development of a novel cardiopulmonary resuscitation measurement tool using real-time feedback from wearable wireless instrumentation' (Ward et al., 2019) in which full context is available'. The data are available at Mendeley Data, doi:10.17632/pvjghfjmy4.1 (Ward et al., 2019). |
format | Online Article Text |
id | pubmed-6811914 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-68119142019-10-30 Data from wearable wireless instrumentation device taken during simulated CPR with and without intentional error toward a quality feedback device Pantanowitz, Adam Ward, Sarah R. Scott, Bronwyn C. Rubin, David M. Data Brief Medicine and Dentistry Data of Cardiopulmonary Resuscitation performed on a mannequin was collected via wearable instrumentation (using the MYO device). The data were collected for both “good” CPR and for performance of CPR with common errors introduced intentionally for this study. The data are labelled according to the error, and contain a variety of derived measurements. Data collected were used toward “Development of a novel cardiopulmonary resuscitation measurement tool using real-time feedback from wearable wireless instrumentation' (Ward et al., 2019) in which full context is available'. The data are available at Mendeley Data, doi:10.17632/pvjghfjmy4.1 (Ward et al., 2019). Elsevier 2019-09-11 /pmc/articles/PMC6811914/ /pubmed/31667218 http://dx.doi.org/10.1016/j.dib.2019.104400 Text en © 2019 The Author(s) http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Medicine and Dentistry Pantanowitz, Adam Ward, Sarah R. Scott, Bronwyn C. Rubin, David M. Data from wearable wireless instrumentation device taken during simulated CPR with and without intentional error toward a quality feedback device |
title | Data from wearable wireless instrumentation device taken during simulated CPR with and without intentional error toward a quality feedback device |
title_full | Data from wearable wireless instrumentation device taken during simulated CPR with and without intentional error toward a quality feedback device |
title_fullStr | Data from wearable wireless instrumentation device taken during simulated CPR with and without intentional error toward a quality feedback device |
title_full_unstemmed | Data from wearable wireless instrumentation device taken during simulated CPR with and without intentional error toward a quality feedback device |
title_short | Data from wearable wireless instrumentation device taken during simulated CPR with and without intentional error toward a quality feedback device |
title_sort | data from wearable wireless instrumentation device taken during simulated cpr with and without intentional error toward a quality feedback device |
topic | Medicine and Dentistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6811914/ https://www.ncbi.nlm.nih.gov/pubmed/31667218 http://dx.doi.org/10.1016/j.dib.2019.104400 |
work_keys_str_mv | AT pantanowitzadam datafromwearablewirelessinstrumentationdevicetakenduringsimulatedcprwithandwithoutintentionalerrortowardaqualityfeedbackdevice AT wardsarahr datafromwearablewirelessinstrumentationdevicetakenduringsimulatedcprwithandwithoutintentionalerrortowardaqualityfeedbackdevice AT scottbronwync datafromwearablewirelessinstrumentationdevicetakenduringsimulatedcprwithandwithoutintentionalerrortowardaqualityfeedbackdevice AT rubindavidm datafromwearablewirelessinstrumentationdevicetakenduringsimulatedcprwithandwithoutintentionalerrortowardaqualityfeedbackdevice |