Cargando…
Agreement between clinical and non-clinical digital manometer for assessing maximal respiratory pressures in healthy subjects
Measurement of respiratory muscles strength such as maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) are used to detect, diagnose and treat respiratory weakness. However, devices used for these measurements are not widely available and are costly. Currently, the use of a digi...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6812781/ https://www.ncbi.nlm.nih.gov/pubmed/31648267 http://dx.doi.org/10.1371/journal.pone.0224357 |
_version_ | 1783462708012646400 |
---|---|
author | Torres-Castro, Rodrigo Sepúlveda-Cáceres, Nicolás Garrido-Baquedano, Rodrigo Barros-Poblete, Marisol Otto-Yáñez, Matías Vasconcello, Luis Vera-Uribe, Roberto Puppo, Homero Fregonezi, Guilherme |
author_facet | Torres-Castro, Rodrigo Sepúlveda-Cáceres, Nicolás Garrido-Baquedano, Rodrigo Barros-Poblete, Marisol Otto-Yáñez, Matías Vasconcello, Luis Vera-Uribe, Roberto Puppo, Homero Fregonezi, Guilherme |
author_sort | Torres-Castro, Rodrigo |
collection | PubMed |
description | Measurement of respiratory muscles strength such as maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) are used to detect, diagnose and treat respiratory weakness. However, devices used for these measurements are not widely available and are costly. Currently, the use of a digital manometer is recommended. In industry, several inexpensive devices are available, but these have not been validated for clinical use. Our objective was to determine the agreement between maximal respiratory pressures obtained with a clinical digital manometer and that with a non-clinical digital manometer in healthy volunteers. We assessed the height, weight, lung function, MIP, and MEP of healthy volunteers. To compare pressures obtained by each type of digital manometer, a parallel approach configuration was used. The agreement was measured with the Intraclass Coefficient Correlation (ICC) and the Bland-Altman plot. Twenty-seven participants (14 men) were recruited with a median age of 22 (range: 21–23) years. Each participant underwent three measurements to give a total of 81 measurements. The mean MIPs were 90.8 ± 26.4 (SEM 2.9) and 91.1 ± 26.4 (SEM 2.9) cmH(2)O for the clinical and non-clinical digital manometers, respectively. The mean MEPs were 113.8 ± 40.4 (SEM 4.5) and 114.5 ± 40.5 (SEM 4.5) cmH(2)O for the clinical and non-clinical digital manometers, respectively. We obtained an ICC of 0.998 (IC 0.997–0.999) for MIP and 0.999 (IC 0.998–0.999) for MEP. There is a high agreement in the values obtained for MIP and MEP between clinical and non-clinical digital manometers in healthy volunteers. Further validation at lower pressures and safety profiling among human subjects is needed. |
format | Online Article Text |
id | pubmed-6812781 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-68127812019-11-03 Agreement between clinical and non-clinical digital manometer for assessing maximal respiratory pressures in healthy subjects Torres-Castro, Rodrigo Sepúlveda-Cáceres, Nicolás Garrido-Baquedano, Rodrigo Barros-Poblete, Marisol Otto-Yáñez, Matías Vasconcello, Luis Vera-Uribe, Roberto Puppo, Homero Fregonezi, Guilherme PLoS One Research Article Measurement of respiratory muscles strength such as maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) are used to detect, diagnose and treat respiratory weakness. However, devices used for these measurements are not widely available and are costly. Currently, the use of a digital manometer is recommended. In industry, several inexpensive devices are available, but these have not been validated for clinical use. Our objective was to determine the agreement between maximal respiratory pressures obtained with a clinical digital manometer and that with a non-clinical digital manometer in healthy volunteers. We assessed the height, weight, lung function, MIP, and MEP of healthy volunteers. To compare pressures obtained by each type of digital manometer, a parallel approach configuration was used. The agreement was measured with the Intraclass Coefficient Correlation (ICC) and the Bland-Altman plot. Twenty-seven participants (14 men) were recruited with a median age of 22 (range: 21–23) years. Each participant underwent three measurements to give a total of 81 measurements. The mean MIPs were 90.8 ± 26.4 (SEM 2.9) and 91.1 ± 26.4 (SEM 2.9) cmH(2)O for the clinical and non-clinical digital manometers, respectively. The mean MEPs were 113.8 ± 40.4 (SEM 4.5) and 114.5 ± 40.5 (SEM 4.5) cmH(2)O for the clinical and non-clinical digital manometers, respectively. We obtained an ICC of 0.998 (IC 0.997–0.999) for MIP and 0.999 (IC 0.998–0.999) for MEP. There is a high agreement in the values obtained for MIP and MEP between clinical and non-clinical digital manometers in healthy volunteers. Further validation at lower pressures and safety profiling among human subjects is needed. Public Library of Science 2019-10-24 /pmc/articles/PMC6812781/ /pubmed/31648267 http://dx.doi.org/10.1371/journal.pone.0224357 Text en © 2019 Torres-Castro et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Torres-Castro, Rodrigo Sepúlveda-Cáceres, Nicolás Garrido-Baquedano, Rodrigo Barros-Poblete, Marisol Otto-Yáñez, Matías Vasconcello, Luis Vera-Uribe, Roberto Puppo, Homero Fregonezi, Guilherme Agreement between clinical and non-clinical digital manometer for assessing maximal respiratory pressures in healthy subjects |
title | Agreement between clinical and non-clinical digital manometer for assessing maximal respiratory pressures in healthy subjects |
title_full | Agreement between clinical and non-clinical digital manometer for assessing maximal respiratory pressures in healthy subjects |
title_fullStr | Agreement between clinical and non-clinical digital manometer for assessing maximal respiratory pressures in healthy subjects |
title_full_unstemmed | Agreement between clinical and non-clinical digital manometer for assessing maximal respiratory pressures in healthy subjects |
title_short | Agreement between clinical and non-clinical digital manometer for assessing maximal respiratory pressures in healthy subjects |
title_sort | agreement between clinical and non-clinical digital manometer for assessing maximal respiratory pressures in healthy subjects |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6812781/ https://www.ncbi.nlm.nih.gov/pubmed/31648267 http://dx.doi.org/10.1371/journal.pone.0224357 |
work_keys_str_mv | AT torrescastrorodrigo agreementbetweenclinicalandnonclinicaldigitalmanometerforassessingmaximalrespiratorypressuresinhealthysubjects AT sepulvedacaceresnicolas agreementbetweenclinicalandnonclinicaldigitalmanometerforassessingmaximalrespiratorypressuresinhealthysubjects AT garridobaquedanorodrigo agreementbetweenclinicalandnonclinicaldigitalmanometerforassessingmaximalrespiratorypressuresinhealthysubjects AT barrospobletemarisol agreementbetweenclinicalandnonclinicaldigitalmanometerforassessingmaximalrespiratorypressuresinhealthysubjects AT ottoyanezmatias agreementbetweenclinicalandnonclinicaldigitalmanometerforassessingmaximalrespiratorypressuresinhealthysubjects AT vasconcelloluis agreementbetweenclinicalandnonclinicaldigitalmanometerforassessingmaximalrespiratorypressuresinhealthysubjects AT verauriberoberto agreementbetweenclinicalandnonclinicaldigitalmanometerforassessingmaximalrespiratorypressuresinhealthysubjects AT puppohomero agreementbetweenclinicalandnonclinicaldigitalmanometerforassessingmaximalrespiratorypressuresinhealthysubjects AT fregoneziguilherme agreementbetweenclinicalandnonclinicaldigitalmanometerforassessingmaximalrespiratorypressuresinhealthysubjects |