Cargando…
An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study
BACKGROUND: Cardiac magnetic resonance imaging (MRI) in large animals is cumbersome for various reasons, including ethical considerations, costs of housing and maintenance, and need for anaesthesia. Our primary purpose was to show the feasibility of an isolated beating pig heart model for four-dimen...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6813403/ https://www.ncbi.nlm.nih.gov/pubmed/31650367 http://dx.doi.org/10.1186/s41747-019-0114-5 |
_version_ | 1783462834445746176 |
---|---|
author | Peper, Eva S. Leopaldi, Alberto M. van Tuijl, Sjoerd Coolen, Bram F. Strijkers, Gustav J. Baan, Jan Planken, R. Nils de Weger, Arend Nederveen, Aart J. Marquering, Henk A. van Ooij, Pim |
author_facet | Peper, Eva S. Leopaldi, Alberto M. van Tuijl, Sjoerd Coolen, Bram F. Strijkers, Gustav J. Baan, Jan Planken, R. Nils de Weger, Arend Nederveen, Aart J. Marquering, Henk A. van Ooij, Pim |
author_sort | Peper, Eva S. |
collection | PubMed |
description | BACKGROUND: Cardiac magnetic resonance imaging (MRI) in large animals is cumbersome for various reasons, including ethical considerations, costs of housing and maintenance, and need for anaesthesia. Our primary purpose was to show the feasibility of an isolated beating pig heart model for four-dimensional (4D) flow MRI for investigating intracardiac blood flow patterns and flow parameters using slaughterhouse side products. In addition, the feasibility of evaluating transcatheter aortic valve replacement (TAVR) in the model was investigated. METHODS: Seven slaughterhouse pig hearts were installed in the MRI-compatible isolated beating pig heart platform. First, Langendorff perfusion mode was established; then, the system switched to working mode, in which blood was actively pumped by the left ventricle. A pacemaker ensured a stable HR during 3-T MRI scanning. All hearts were submitted to human physiological conditions of cardiac output and stayed vital for several hours. Aortic flow was measured from which stroke volume, cardiac output, and regurgitation fraction were calculated. RESULTS: 4D flow MRI acquisitions were successfully conducted in all hearts. Stroke volume was 31 ± 6 mL (mean ± standard deviation), cardiac output 3.3 ± 0.9 L/min, and regurgitation fraction 16% ± 9%. With 4D flow, intracardiac and coronary flow patterns could be visualised in all hearts. In addition, we could study valve function and regurgitation in two hearts after TAVR. CONCLUSIONS: The feasibility of 4D flow MRI in an isolated beating pig heart loaded to physiological conditions was demonstrated. The platform is promising for preclinical assessment of cardiac blood flow and function. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s41747-019-0114-5) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6813403 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-68134032019-11-08 An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study Peper, Eva S. Leopaldi, Alberto M. van Tuijl, Sjoerd Coolen, Bram F. Strijkers, Gustav J. Baan, Jan Planken, R. Nils de Weger, Arend Nederveen, Aart J. Marquering, Henk A. van Ooij, Pim Eur Radiol Exp Original Article BACKGROUND: Cardiac magnetic resonance imaging (MRI) in large animals is cumbersome for various reasons, including ethical considerations, costs of housing and maintenance, and need for anaesthesia. Our primary purpose was to show the feasibility of an isolated beating pig heart model for four-dimensional (4D) flow MRI for investigating intracardiac blood flow patterns and flow parameters using slaughterhouse side products. In addition, the feasibility of evaluating transcatheter aortic valve replacement (TAVR) in the model was investigated. METHODS: Seven slaughterhouse pig hearts were installed in the MRI-compatible isolated beating pig heart platform. First, Langendorff perfusion mode was established; then, the system switched to working mode, in which blood was actively pumped by the left ventricle. A pacemaker ensured a stable HR during 3-T MRI scanning. All hearts were submitted to human physiological conditions of cardiac output and stayed vital for several hours. Aortic flow was measured from which stroke volume, cardiac output, and regurgitation fraction were calculated. RESULTS: 4D flow MRI acquisitions were successfully conducted in all hearts. Stroke volume was 31 ± 6 mL (mean ± standard deviation), cardiac output 3.3 ± 0.9 L/min, and regurgitation fraction 16% ± 9%. With 4D flow, intracardiac and coronary flow patterns could be visualised in all hearts. In addition, we could study valve function and regurgitation in two hearts after TAVR. CONCLUSIONS: The feasibility of 4D flow MRI in an isolated beating pig heart loaded to physiological conditions was demonstrated. The platform is promising for preclinical assessment of cardiac blood flow and function. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s41747-019-0114-5) contains supplementary material, which is available to authorized users. Springer International Publishing 2019-10-25 /pmc/articles/PMC6813403/ /pubmed/31650367 http://dx.doi.org/10.1186/s41747-019-0114-5 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Peper, Eva S. Leopaldi, Alberto M. van Tuijl, Sjoerd Coolen, Bram F. Strijkers, Gustav J. Baan, Jan Planken, R. Nils de Weger, Arend Nederveen, Aart J. Marquering, Henk A. van Ooij, Pim An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study |
title | An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study |
title_full | An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study |
title_fullStr | An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study |
title_full_unstemmed | An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study |
title_short | An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study |
title_sort | isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4d flow mri: a feasibility study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6813403/ https://www.ncbi.nlm.nih.gov/pubmed/31650367 http://dx.doi.org/10.1186/s41747-019-0114-5 |
work_keys_str_mv | AT peperevas anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT leopaldialbertom anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT vantuijlsjoerd anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT coolenbramf anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT strijkersgustavj anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT baanjan anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT plankenrnils anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT dewegerarend anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT nederveenaartj anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT marqueringhenka anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT vanooijpim anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT peperevas isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT leopaldialbertom isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT vantuijlsjoerd isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT coolenbramf isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT strijkersgustavj isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT baanjan isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT plankenrnils isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT dewegerarend isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT nederveenaartj isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT marqueringhenka isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy AT vanooijpim isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy |