Cargando…

An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study

BACKGROUND: Cardiac magnetic resonance imaging (MRI) in large animals is cumbersome for various reasons, including ethical considerations, costs of housing and maintenance, and need for anaesthesia. Our primary purpose was to show the feasibility of an isolated beating pig heart model for four-dimen...

Descripción completa

Detalles Bibliográficos
Autores principales: Peper, Eva S., Leopaldi, Alberto M., van Tuijl, Sjoerd, Coolen, Bram F., Strijkers, Gustav J., Baan, Jan, Planken, R. Nils, de Weger, Arend, Nederveen, Aart J., Marquering, Henk A., van Ooij, Pim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6813403/
https://www.ncbi.nlm.nih.gov/pubmed/31650367
http://dx.doi.org/10.1186/s41747-019-0114-5
_version_ 1783462834445746176
author Peper, Eva S.
Leopaldi, Alberto M.
van Tuijl, Sjoerd
Coolen, Bram F.
Strijkers, Gustav J.
Baan, Jan
Planken, R. Nils
de Weger, Arend
Nederveen, Aart J.
Marquering, Henk A.
van Ooij, Pim
author_facet Peper, Eva S.
Leopaldi, Alberto M.
van Tuijl, Sjoerd
Coolen, Bram F.
Strijkers, Gustav J.
Baan, Jan
Planken, R. Nils
de Weger, Arend
Nederveen, Aart J.
Marquering, Henk A.
van Ooij, Pim
author_sort Peper, Eva S.
collection PubMed
description BACKGROUND: Cardiac magnetic resonance imaging (MRI) in large animals is cumbersome for various reasons, including ethical considerations, costs of housing and maintenance, and need for anaesthesia. Our primary purpose was to show the feasibility of an isolated beating pig heart model for four-dimensional (4D) flow MRI for investigating intracardiac blood flow patterns and flow parameters using slaughterhouse side products. In addition, the feasibility of evaluating transcatheter aortic valve replacement (TAVR) in the model was investigated. METHODS: Seven slaughterhouse pig hearts were installed in the MRI-compatible isolated beating pig heart platform. First, Langendorff perfusion mode was established; then, the system switched to working mode, in which blood was actively pumped by the left ventricle. A pacemaker ensured a stable HR during 3-T MRI scanning. All hearts were submitted to human physiological conditions of cardiac output and stayed vital for several hours. Aortic flow was measured from which stroke volume, cardiac output, and regurgitation fraction were calculated. RESULTS: 4D flow MRI acquisitions were successfully conducted in all hearts. Stroke volume was 31 ± 6 mL (mean ± standard deviation), cardiac output 3.3 ± 0.9 L/min, and regurgitation fraction 16% ± 9%. With 4D flow, intracardiac and coronary flow patterns could be visualised in all hearts. In addition, we could study valve function and regurgitation in two hearts after TAVR. CONCLUSIONS: The feasibility of 4D flow MRI in an isolated beating pig heart loaded to physiological conditions was demonstrated. The platform is promising for preclinical assessment of cardiac blood flow and function. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s41747-019-0114-5) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6813403
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-68134032019-11-08 An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study Peper, Eva S. Leopaldi, Alberto M. van Tuijl, Sjoerd Coolen, Bram F. Strijkers, Gustav J. Baan, Jan Planken, R. Nils de Weger, Arend Nederveen, Aart J. Marquering, Henk A. van Ooij, Pim Eur Radiol Exp Original Article BACKGROUND: Cardiac magnetic resonance imaging (MRI) in large animals is cumbersome for various reasons, including ethical considerations, costs of housing and maintenance, and need for anaesthesia. Our primary purpose was to show the feasibility of an isolated beating pig heart model for four-dimensional (4D) flow MRI for investigating intracardiac blood flow patterns and flow parameters using slaughterhouse side products. In addition, the feasibility of evaluating transcatheter aortic valve replacement (TAVR) in the model was investigated. METHODS: Seven slaughterhouse pig hearts were installed in the MRI-compatible isolated beating pig heart platform. First, Langendorff perfusion mode was established; then, the system switched to working mode, in which blood was actively pumped by the left ventricle. A pacemaker ensured a stable HR during 3-T MRI scanning. All hearts were submitted to human physiological conditions of cardiac output and stayed vital for several hours. Aortic flow was measured from which stroke volume, cardiac output, and regurgitation fraction were calculated. RESULTS: 4D flow MRI acquisitions were successfully conducted in all hearts. Stroke volume was 31 ± 6 mL (mean ± standard deviation), cardiac output 3.3 ± 0.9 L/min, and regurgitation fraction 16% ± 9%. With 4D flow, intracardiac and coronary flow patterns could be visualised in all hearts. In addition, we could study valve function and regurgitation in two hearts after TAVR. CONCLUSIONS: The feasibility of 4D flow MRI in an isolated beating pig heart loaded to physiological conditions was demonstrated. The platform is promising for preclinical assessment of cardiac blood flow and function. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s41747-019-0114-5) contains supplementary material, which is available to authorized users. Springer International Publishing 2019-10-25 /pmc/articles/PMC6813403/ /pubmed/31650367 http://dx.doi.org/10.1186/s41747-019-0114-5 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Peper, Eva S.
Leopaldi, Alberto M.
van Tuijl, Sjoerd
Coolen, Bram F.
Strijkers, Gustav J.
Baan, Jan
Planken, R. Nils
de Weger, Arend
Nederveen, Aart J.
Marquering, Henk A.
van Ooij, Pim
An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study
title An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study
title_full An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study
title_fullStr An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study
title_full_unstemmed An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study
title_short An isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4D flow MRI: a feasibility study
title_sort isolated beating pig heart platform for a comprehensive evaluation of intracardiac blood flow with 4d flow mri: a feasibility study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6813403/
https://www.ncbi.nlm.nih.gov/pubmed/31650367
http://dx.doi.org/10.1186/s41747-019-0114-5
work_keys_str_mv AT peperevas anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT leopaldialbertom anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT vantuijlsjoerd anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT coolenbramf anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT strijkersgustavj anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT baanjan anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT plankenrnils anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT dewegerarend anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT nederveenaartj anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT marqueringhenka anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT vanooijpim anisolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT peperevas isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT leopaldialbertom isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT vantuijlsjoerd isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT coolenbramf isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT strijkersgustavj isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT baanjan isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT plankenrnils isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT dewegerarend isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT nederveenaartj isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT marqueringhenka isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy
AT vanooijpim isolatedbeatingpigheartplatformforacomprehensiveevaluationofintracardiacbloodflowwith4dflowmriafeasibilitystudy