Cargando…
Performance evaluation of Cerenkov luminescence imaging: a comparison of (68)Ga with (18)F
BACKGROUND: Cerenkov Luminescence Imaging (CLI) is an emerging technology for intraoperative margin assessment. Previous research only evaluated radionuclide 18-Fluorine ((18)F); however, for future applications in prostate cancer, 68-Gallium ((68)Ga) seems more suitable, given its higher positron e...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6813407/ https://www.ncbi.nlm.nih.gov/pubmed/31650365 http://dx.doi.org/10.1186/s40658-019-0255-x |
_version_ | 1783462835407290368 |
---|---|
author | olde Heuvel, J. de Wit-van der Veen, B. J. Vyas, K. N. Tuch, D. S. Grootendorst, M. R. Stokkel, M. P. M. Slump, C. H. |
author_facet | olde Heuvel, J. de Wit-van der Veen, B. J. Vyas, K. N. Tuch, D. S. Grootendorst, M. R. Stokkel, M. P. M. Slump, C. H. |
author_sort | olde Heuvel, J. |
collection | PubMed |
description | BACKGROUND: Cerenkov Luminescence Imaging (CLI) is an emerging technology for intraoperative margin assessment. Previous research only evaluated radionuclide 18-Fluorine ((18)F); however, for future applications in prostate cancer, 68-Gallium ((68)Ga) seems more suitable, given its higher positron energy. Theoretical calculations predict that (68)Ga should offer a higher signal-to-noise ratio than (18)F; this is the first experimental confirmation. The aim of this study is to investigate the technical performance of CLI by comparing (68)Ga to (18)F. RESULTS: The linearity of the system, detection limit, spatial resolution, and uniformity were determined with the LightPath imaging system. All experiments were conducted with clinically relevant activity levels in vitro, using dedicated phantoms. For both radionuclides, a linear relationship between the activity concentration and detected light yield was observed (R(2) = 0.99). (68)Ga showed approximately 22 times more detectable Cerenkov signal compared to (18)F. The detectable activity concentration after a 120 s exposure time and 2 × 2 binning of (18)F was 23.7 kBq/mL and 1.2 kBq/mL for (68)Ga. The spatial resolution was 1.31 mm for (18)F and 1.40 mm for (68)Ga. The coefficient of variance of the uniformity phantom was 0.07 for the central field of view. CONCLUSION: (68)Ga was superior over (18)F in terms of light yield and minimal detection limit. However, as could be expected, the resolution was 0.1 mm less for (68)Ga. Given the clinical constraints of an acquisition time less than 120 s and a spatial resolution < 2 mm, CLI for intraoperative margin assessment using (68)Ga could be feasible. |
format | Online Article Text |
id | pubmed-6813407 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-68134072019-11-08 Performance evaluation of Cerenkov luminescence imaging: a comparison of (68)Ga with (18)F olde Heuvel, J. de Wit-van der Veen, B. J. Vyas, K. N. Tuch, D. S. Grootendorst, M. R. Stokkel, M. P. M. Slump, C. H. EJNMMI Phys Original Research BACKGROUND: Cerenkov Luminescence Imaging (CLI) is an emerging technology for intraoperative margin assessment. Previous research only evaluated radionuclide 18-Fluorine ((18)F); however, for future applications in prostate cancer, 68-Gallium ((68)Ga) seems more suitable, given its higher positron energy. Theoretical calculations predict that (68)Ga should offer a higher signal-to-noise ratio than (18)F; this is the first experimental confirmation. The aim of this study is to investigate the technical performance of CLI by comparing (68)Ga to (18)F. RESULTS: The linearity of the system, detection limit, spatial resolution, and uniformity were determined with the LightPath imaging system. All experiments were conducted with clinically relevant activity levels in vitro, using dedicated phantoms. For both radionuclides, a linear relationship between the activity concentration and detected light yield was observed (R(2) = 0.99). (68)Ga showed approximately 22 times more detectable Cerenkov signal compared to (18)F. The detectable activity concentration after a 120 s exposure time and 2 × 2 binning of (18)F was 23.7 kBq/mL and 1.2 kBq/mL for (68)Ga. The spatial resolution was 1.31 mm for (18)F and 1.40 mm for (68)Ga. The coefficient of variance of the uniformity phantom was 0.07 for the central field of view. CONCLUSION: (68)Ga was superior over (18)F in terms of light yield and minimal detection limit. However, as could be expected, the resolution was 0.1 mm less for (68)Ga. Given the clinical constraints of an acquisition time less than 120 s and a spatial resolution < 2 mm, CLI for intraoperative margin assessment using (68)Ga could be feasible. Springer International Publishing 2019-10-24 /pmc/articles/PMC6813407/ /pubmed/31650365 http://dx.doi.org/10.1186/s40658-019-0255-x Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Research olde Heuvel, J. de Wit-van der Veen, B. J. Vyas, K. N. Tuch, D. S. Grootendorst, M. R. Stokkel, M. P. M. Slump, C. H. Performance evaluation of Cerenkov luminescence imaging: a comparison of (68)Ga with (18)F |
title | Performance evaluation of Cerenkov luminescence imaging: a comparison of (68)Ga with (18)F |
title_full | Performance evaluation of Cerenkov luminescence imaging: a comparison of (68)Ga with (18)F |
title_fullStr | Performance evaluation of Cerenkov luminescence imaging: a comparison of (68)Ga with (18)F |
title_full_unstemmed | Performance evaluation of Cerenkov luminescence imaging: a comparison of (68)Ga with (18)F |
title_short | Performance evaluation of Cerenkov luminescence imaging: a comparison of (68)Ga with (18)F |
title_sort | performance evaluation of cerenkov luminescence imaging: a comparison of (68)ga with (18)f |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6813407/ https://www.ncbi.nlm.nih.gov/pubmed/31650365 http://dx.doi.org/10.1186/s40658-019-0255-x |
work_keys_str_mv | AT oldeheuvelj performanceevaluationofcerenkovluminescenceimagingacomparisonof68gawith18f AT dewitvanderveenbj performanceevaluationofcerenkovluminescenceimagingacomparisonof68gawith18f AT vyaskn performanceevaluationofcerenkovluminescenceimagingacomparisonof68gawith18f AT tuchds performanceevaluationofcerenkovluminescenceimagingacomparisonof68gawith18f AT grootendorstmr performanceevaluationofcerenkovluminescenceimagingacomparisonof68gawith18f AT stokkelmpm performanceevaluationofcerenkovluminescenceimagingacomparisonof68gawith18f AT slumpch performanceevaluationofcerenkovluminescenceimagingacomparisonof68gawith18f |