Cargando…

No added value for Computer-Assisted surgery to improve femoral component positioning and Patient Reported Outcomes in Hip Resurfacing Arthroplasty; a multi-center randomized controlled trial

BACKGROUND: Computer Assisted Surgery (CAS) has proven to improve the accuracy in several orthopedic procedures. Therefore we used this technique to evaluate femoral component positioning in Hip Resurfacing Arthroplasty (HRA). The aim of this study was to evaluate imageless CAS compared to manually...

Descripción completa

Detalles Bibliográficos
Autores principales: Koper, M. C., Reijman, M., van Es, E. M., Waarsing, J. H., Koot, H. W. J., Keizer, S. B., Jansen, I., van Biezen, F. C., Verhaar, J. A. N., Bos, P. K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6814023/
https://www.ncbi.nlm.nih.gov/pubmed/31651318
http://dx.doi.org/10.1186/s12891-019-2883-7
_version_ 1783462941418323968
author Koper, M. C.
Reijman, M.
van Es, E. M.
Waarsing, J. H.
Koot, H. W. J.
Keizer, S. B.
Jansen, I.
van Biezen, F. C.
Verhaar, J. A. N.
Bos, P. K.
author_facet Koper, M. C.
Reijman, M.
van Es, E. M.
Waarsing, J. H.
Koot, H. W. J.
Keizer, S. B.
Jansen, I.
van Biezen, F. C.
Verhaar, J. A. N.
Bos, P. K.
author_sort Koper, M. C.
collection PubMed
description BACKGROUND: Computer Assisted Surgery (CAS) has proven to improve the accuracy in several orthopedic procedures. Therefore we used this technique to evaluate femoral component positioning in Hip Resurfacing Arthroplasty (HRA). The aim of this study was to evaluate imageless CAS compared to manually implanted femoral components and subsequently evaluates Patient Related Outcome Measures (PROMs). We hypothesized that the use of CAS optimizes the position of the femoral component and improves PROMs. METHODS: This is a multicenter, single-blinded, randomized, controlled trial of two groups. In the CAS group guiding of the femoral component was done with imageless navigation. In the Conventional (control) group the femoral component was placed manually according to the preplanned position. The primary outcome measure consists of a maximum of 3 degrees difference between the postoperative Stem Shaft Angle (SSA) and preplanned SSA. Secondary outcome measures consist of the Hip disability and Osteoarthritis Outcome Scale (HOOS), the Harris Hip Score (HHS) and Visual Analogue Scale (VAS) pain score. RESULTS: A total of 122 patients were randomized, 61 in the CAS group and 61 in the conventional group. There was no significant differences in accuracy of femoral implant position. The mean difference between the postoperative- and preplanned SSA was − 2.26 and − 1.75 degrees (more varus) respectively in the CAS and Conventional group. After surgery both groups show significant improvement in all PROMs compared to the baseline measurements, with no significant differences between the groups. CONCLUSION: Our cohort indicates no benefit for the use of CAS in accuracy of placement of the femoral component in HRA compared to manual implantation. There are no clinical differences in PROMs after 1 year follow up. This study showed no added value and no justification for the use of CAS in femoral component positioning in HRA. TRIAL REGISTRATION: This trial is registered at ClinicalTrails.gov (https://clinicaltrials.gov/) on the 25th of October 2006: NCT00391937. LEVEL OF INCIDENCE: Level IIb, multicenter randomized controlled trial.
format Online
Article
Text
id pubmed-6814023
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-68140232019-10-31 No added value for Computer-Assisted surgery to improve femoral component positioning and Patient Reported Outcomes in Hip Resurfacing Arthroplasty; a multi-center randomized controlled trial Koper, M. C. Reijman, M. van Es, E. M. Waarsing, J. H. Koot, H. W. J. Keizer, S. B. Jansen, I. van Biezen, F. C. Verhaar, J. A. N. Bos, P. K. BMC Musculoskelet Disord Research Article BACKGROUND: Computer Assisted Surgery (CAS) has proven to improve the accuracy in several orthopedic procedures. Therefore we used this technique to evaluate femoral component positioning in Hip Resurfacing Arthroplasty (HRA). The aim of this study was to evaluate imageless CAS compared to manually implanted femoral components and subsequently evaluates Patient Related Outcome Measures (PROMs). We hypothesized that the use of CAS optimizes the position of the femoral component and improves PROMs. METHODS: This is a multicenter, single-blinded, randomized, controlled trial of two groups. In the CAS group guiding of the femoral component was done with imageless navigation. In the Conventional (control) group the femoral component was placed manually according to the preplanned position. The primary outcome measure consists of a maximum of 3 degrees difference between the postoperative Stem Shaft Angle (SSA) and preplanned SSA. Secondary outcome measures consist of the Hip disability and Osteoarthritis Outcome Scale (HOOS), the Harris Hip Score (HHS) and Visual Analogue Scale (VAS) pain score. RESULTS: A total of 122 patients were randomized, 61 in the CAS group and 61 in the conventional group. There was no significant differences in accuracy of femoral implant position. The mean difference between the postoperative- and preplanned SSA was − 2.26 and − 1.75 degrees (more varus) respectively in the CAS and Conventional group. After surgery both groups show significant improvement in all PROMs compared to the baseline measurements, with no significant differences between the groups. CONCLUSION: Our cohort indicates no benefit for the use of CAS in accuracy of placement of the femoral component in HRA compared to manual implantation. There are no clinical differences in PROMs after 1 year follow up. This study showed no added value and no justification for the use of CAS in femoral component positioning in HRA. TRIAL REGISTRATION: This trial is registered at ClinicalTrails.gov (https://clinicaltrials.gov/) on the 25th of October 2006: NCT00391937. LEVEL OF INCIDENCE: Level IIb, multicenter randomized controlled trial. BioMed Central 2019-10-25 /pmc/articles/PMC6814023/ /pubmed/31651318 http://dx.doi.org/10.1186/s12891-019-2883-7 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Koper, M. C.
Reijman, M.
van Es, E. M.
Waarsing, J. H.
Koot, H. W. J.
Keizer, S. B.
Jansen, I.
van Biezen, F. C.
Verhaar, J. A. N.
Bos, P. K.
No added value for Computer-Assisted surgery to improve femoral component positioning and Patient Reported Outcomes in Hip Resurfacing Arthroplasty; a multi-center randomized controlled trial
title No added value for Computer-Assisted surgery to improve femoral component positioning and Patient Reported Outcomes in Hip Resurfacing Arthroplasty; a multi-center randomized controlled trial
title_full No added value for Computer-Assisted surgery to improve femoral component positioning and Patient Reported Outcomes in Hip Resurfacing Arthroplasty; a multi-center randomized controlled trial
title_fullStr No added value for Computer-Assisted surgery to improve femoral component positioning and Patient Reported Outcomes in Hip Resurfacing Arthroplasty; a multi-center randomized controlled trial
title_full_unstemmed No added value for Computer-Assisted surgery to improve femoral component positioning and Patient Reported Outcomes in Hip Resurfacing Arthroplasty; a multi-center randomized controlled trial
title_short No added value for Computer-Assisted surgery to improve femoral component positioning and Patient Reported Outcomes in Hip Resurfacing Arthroplasty; a multi-center randomized controlled trial
title_sort no added value for computer-assisted surgery to improve femoral component positioning and patient reported outcomes in hip resurfacing arthroplasty; a multi-center randomized controlled trial
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6814023/
https://www.ncbi.nlm.nih.gov/pubmed/31651318
http://dx.doi.org/10.1186/s12891-019-2883-7
work_keys_str_mv AT kopermc noaddedvalueforcomputerassistedsurgerytoimprovefemoralcomponentpositioningandpatientreportedoutcomesinhipresurfacingarthroplastyamulticenterrandomizedcontrolledtrial
AT reijmanm noaddedvalueforcomputerassistedsurgerytoimprovefemoralcomponentpositioningandpatientreportedoutcomesinhipresurfacingarthroplastyamulticenterrandomizedcontrolledtrial
AT vanesem noaddedvalueforcomputerassistedsurgerytoimprovefemoralcomponentpositioningandpatientreportedoutcomesinhipresurfacingarthroplastyamulticenterrandomizedcontrolledtrial
AT waarsingjh noaddedvalueforcomputerassistedsurgerytoimprovefemoralcomponentpositioningandpatientreportedoutcomesinhipresurfacingarthroplastyamulticenterrandomizedcontrolledtrial
AT koothwj noaddedvalueforcomputerassistedsurgerytoimprovefemoralcomponentpositioningandpatientreportedoutcomesinhipresurfacingarthroplastyamulticenterrandomizedcontrolledtrial
AT keizersb noaddedvalueforcomputerassistedsurgerytoimprovefemoralcomponentpositioningandpatientreportedoutcomesinhipresurfacingarthroplastyamulticenterrandomizedcontrolledtrial
AT janseni noaddedvalueforcomputerassistedsurgerytoimprovefemoralcomponentpositioningandpatientreportedoutcomesinhipresurfacingarthroplastyamulticenterrandomizedcontrolledtrial
AT vanbiezenfc noaddedvalueforcomputerassistedsurgerytoimprovefemoralcomponentpositioningandpatientreportedoutcomesinhipresurfacingarthroplastyamulticenterrandomizedcontrolledtrial
AT verhaarjan noaddedvalueforcomputerassistedsurgerytoimprovefemoralcomponentpositioningandpatientreportedoutcomesinhipresurfacingarthroplastyamulticenterrandomizedcontrolledtrial
AT bospk noaddedvalueforcomputerassistedsurgerytoimprovefemoralcomponentpositioningandpatientreportedoutcomesinhipresurfacingarthroplastyamulticenterrandomizedcontrolledtrial