Cargando…

Repeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes

To evaluate the repeatability of corneal biomechanical parameters in normal and keratoconus eyes, and explore factors that affects the repeatability, and further assess the diagnostic ability of new parameters. Seventy-seven keratoconus eyes of 47 patients and 77 right eyes of 77 normal subjects wer...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Kaili, Xu, Liyan, Fan, Qi, Zhao*, Dongqing, Ren*, Shengwei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6814725/
https://www.ncbi.nlm.nih.gov/pubmed/31653884
http://dx.doi.org/10.1038/s41598-019-51502-4
_version_ 1783463041076035584
author Yang, Kaili
Xu, Liyan
Fan, Qi
Zhao*, Dongqing
Ren*, Shengwei
author_facet Yang, Kaili
Xu, Liyan
Fan, Qi
Zhao*, Dongqing
Ren*, Shengwei
author_sort Yang, Kaili
collection PubMed
description To evaluate the repeatability of corneal biomechanical parameters in normal and keratoconus eyes, and explore factors that affects the repeatability, and further assess the diagnostic ability of new parameters. Seventy-seven keratoconus eyes of 47 patients and 77 right eyes of 77 normal subjects were recruited in current study. All participants received three repeated measurements with 2 to 5 minutes interval. The interclass correlation coefficient (ICC), Cronbach’ α and repeatability coefficient (RC) were evaluated. The liner regression analysis was used to identify factors that affect the repeatability, and linear mixed effects model was performed to compare the parameters differences. The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic ability of new parameters. Eighteen parameters in normal eyes and twenty-two parameters in keratoconus eyes showed excellent repeatability (ICC ≥ 0.90). Age, axial measurement (AL), spherical equivalent, astigmatism, gender, mean keratometry (Kmean), intraocular pressure (IOP) and central corneal thickness (CCT) could affect the repeatability of new Corvis ST parameters. Compared with normal eyes, the Ambrósio’s Relational Thickness horizontal (ARTh), biomechanical corrected IOP (bIOP), stiffness parameter at first applanation (SP A1) were low and the Max Inverse Radius, deformation amplitude (DA) Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Integrated Radius and Corvis Biomechanical Index (CBI) were high in keratoconus eyes (All P < 0.05). Both ARTh and CBI had high Youden index (0.870), and the corresponding cut-off values were 379.29 and 0.44. The repeatability of Corvis ST parameters was acceptable both in normal and keratoconus eyes, and new parameters could effectively diagnose keratoconus eyes from normal eyes.
format Online
Article
Text
id pubmed-6814725
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-68147252019-10-30 Repeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes Yang, Kaili Xu, Liyan Fan, Qi Zhao*, Dongqing Ren*, Shengwei Sci Rep Article To evaluate the repeatability of corneal biomechanical parameters in normal and keratoconus eyes, and explore factors that affects the repeatability, and further assess the diagnostic ability of new parameters. Seventy-seven keratoconus eyes of 47 patients and 77 right eyes of 77 normal subjects were recruited in current study. All participants received three repeated measurements with 2 to 5 minutes interval. The interclass correlation coefficient (ICC), Cronbach’ α and repeatability coefficient (RC) were evaluated. The liner regression analysis was used to identify factors that affect the repeatability, and linear mixed effects model was performed to compare the parameters differences. The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic ability of new parameters. Eighteen parameters in normal eyes and twenty-two parameters in keratoconus eyes showed excellent repeatability (ICC ≥ 0.90). Age, axial measurement (AL), spherical equivalent, astigmatism, gender, mean keratometry (Kmean), intraocular pressure (IOP) and central corneal thickness (CCT) could affect the repeatability of new Corvis ST parameters. Compared with normal eyes, the Ambrósio’s Relational Thickness horizontal (ARTh), biomechanical corrected IOP (bIOP), stiffness parameter at first applanation (SP A1) were low and the Max Inverse Radius, deformation amplitude (DA) Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Integrated Radius and Corvis Biomechanical Index (CBI) were high in keratoconus eyes (All P < 0.05). Both ARTh and CBI had high Youden index (0.870), and the corresponding cut-off values were 379.29 and 0.44. The repeatability of Corvis ST parameters was acceptable both in normal and keratoconus eyes, and new parameters could effectively diagnose keratoconus eyes from normal eyes. Nature Publishing Group UK 2019-10-25 /pmc/articles/PMC6814725/ /pubmed/31653884 http://dx.doi.org/10.1038/s41598-019-51502-4 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Yang, Kaili
Xu, Liyan
Fan, Qi
Zhao*, Dongqing
Ren*, Shengwei
Repeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes
title Repeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes
title_full Repeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes
title_fullStr Repeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes
title_full_unstemmed Repeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes
title_short Repeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes
title_sort repeatability and comparison of new corvis st parameters in normal and keratoconus eyes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6814725/
https://www.ncbi.nlm.nih.gov/pubmed/31653884
http://dx.doi.org/10.1038/s41598-019-51502-4
work_keys_str_mv AT yangkaili repeatabilityandcomparisonofnewcorvisstparametersinnormalandkeratoconuseyes
AT xuliyan repeatabilityandcomparisonofnewcorvisstparametersinnormalandkeratoconuseyes
AT fanqi repeatabilityandcomparisonofnewcorvisstparametersinnormalandkeratoconuseyes
AT zhaodongqing repeatabilityandcomparisonofnewcorvisstparametersinnormalandkeratoconuseyes
AT renshengwei repeatabilityandcomparisonofnewcorvisstparametersinnormalandkeratoconuseyes