Potential use of a diluted high-relaxivity gadolinium-based intra-articular contrast agent for magnetic resonance arthrography: an in-vitro study
BACKGROUND: Magnetic resonance arthrography (MRA) requires intra-articular injection of gadolinium-based diluted paramagnetic contrast material. To our knowledge, gadobenate dimeglumine (Gd-BOPTA) has never been used for intra-articular applications. Our aim was to test in vitro different concentrat...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6815038/ https://www.ncbi.nlm.nih.gov/pubmed/31653206 http://dx.doi.org/10.1186/s12880-019-0387-4 |
_version_ | 1783463118453604352 |
---|---|
author | Messina, Carmelo Albano, Domenico Orlandi, Davide Chianca, Vito Corazza, Angelo Ferrari, Federica Gitto, Salvatore Sconfienza, Luca Maria |
author_facet | Messina, Carmelo Albano, Domenico Orlandi, Davide Chianca, Vito Corazza, Angelo Ferrari, Federica Gitto, Salvatore Sconfienza, Luca Maria |
author_sort | Messina, Carmelo |
collection | PubMed |
description | BACKGROUND: Magnetic resonance arthrography (MRA) requires intra-articular injection of gadolinium-based diluted paramagnetic contrast material. To our knowledge, gadobenate dimeglumine (Gd-BOPTA) has never been used for intra-articular applications. Our aim was to test in vitro different concentrations of Gd-BOPTA to be potentially used to perform MRA. METHODS: Gd-BOPTA was diluted in saline (NaCl 0.9%) to achieve different concentrations (4 mmol/l; 2 mmol/l; 1 mmol/l; 0.67 mmol/l; 0.5 mmol/l). Six sets of five sterile pipes were prepared with 5 ml of each solution, five sets added with 0.5 ml of fresh synovial fluid. Two separate pipes were prepared with 5 ml of gadopentetate dimeglumine (Gd-DTPA) at 2 mmol/l, one pipe added with 0.5 ml of synovial fluid. Pipes were imaged using a T1-weighted sequence at 1.5 T. For each pipe, signal intensity (SI) in arbitrary units (au) was measured. RESULTS: SI reproducibility range was 86–99%. Mean Gd-BOPTA SI in pipes containing synovial fluid increased from 1236 ± 8au (0.5 mmol/l) up to 1610 ± 44au (1 mmol/l) and down to 1405 ± 33au (4 mmol/l). Mean Gd-BOPTA SI in pipes without synovial fluid increased from 1184 ± 29au (0.5 mmol/l) up to 1530 ± 38au (1 mmol/l), and down to 1347 ± 39au (4 mmol/l). SI of pipes without synovial fluid was lower than that of pipes with synovial fluid for both Gd-BOPTA and Gd-DTPA (P ≤ 0.002). Regarding pipes with synovial fluid, mean Gd-DTPA SI at 2 mmol/l was 1246 ± 27au. Compared with Gd-BOPTA, SI was not different at 0.5 mmol/l (− 0.2%, P = 0.587) while it was higher (P < 0.001) at all other concentrations (range + 13.3%[4 mmol/l] − + 28.3%[1 mmol/l]). Regarding pipes without synovial fluid, mean Gd-DTPA SI at 2 mmol/l was 1275 ± 56au. Compared with Gd-BOPTA, SI was lower at 0.5 mmol/l (− 6.8%,P < 0.001), while it was higher (P < 0.001) at all other concentrations (range + 6.1%[4 mmol/l] − + 19.6% [1 mmol/l]). CONCLUSIONS: In vitro, Gd-BOPTA at 1 mmol/ had a + 28% SI increase in comparison to Gd-DTPA 2 mmol/l. SI similar to Gd-DTPA can be obtained using one fourth concentration of Gd-BOPTA. |
format | Online Article Text |
id | pubmed-6815038 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-68150382019-10-31 Potential use of a diluted high-relaxivity gadolinium-based intra-articular contrast agent for magnetic resonance arthrography: an in-vitro study Messina, Carmelo Albano, Domenico Orlandi, Davide Chianca, Vito Corazza, Angelo Ferrari, Federica Gitto, Salvatore Sconfienza, Luca Maria BMC Med Imaging Research Article BACKGROUND: Magnetic resonance arthrography (MRA) requires intra-articular injection of gadolinium-based diluted paramagnetic contrast material. To our knowledge, gadobenate dimeglumine (Gd-BOPTA) has never been used for intra-articular applications. Our aim was to test in vitro different concentrations of Gd-BOPTA to be potentially used to perform MRA. METHODS: Gd-BOPTA was diluted in saline (NaCl 0.9%) to achieve different concentrations (4 mmol/l; 2 mmol/l; 1 mmol/l; 0.67 mmol/l; 0.5 mmol/l). Six sets of five sterile pipes were prepared with 5 ml of each solution, five sets added with 0.5 ml of fresh synovial fluid. Two separate pipes were prepared with 5 ml of gadopentetate dimeglumine (Gd-DTPA) at 2 mmol/l, one pipe added with 0.5 ml of synovial fluid. Pipes were imaged using a T1-weighted sequence at 1.5 T. For each pipe, signal intensity (SI) in arbitrary units (au) was measured. RESULTS: SI reproducibility range was 86–99%. Mean Gd-BOPTA SI in pipes containing synovial fluid increased from 1236 ± 8au (0.5 mmol/l) up to 1610 ± 44au (1 mmol/l) and down to 1405 ± 33au (4 mmol/l). Mean Gd-BOPTA SI in pipes without synovial fluid increased from 1184 ± 29au (0.5 mmol/l) up to 1530 ± 38au (1 mmol/l), and down to 1347 ± 39au (4 mmol/l). SI of pipes without synovial fluid was lower than that of pipes with synovial fluid for both Gd-BOPTA and Gd-DTPA (P ≤ 0.002). Regarding pipes with synovial fluid, mean Gd-DTPA SI at 2 mmol/l was 1246 ± 27au. Compared with Gd-BOPTA, SI was not different at 0.5 mmol/l (− 0.2%, P = 0.587) while it was higher (P < 0.001) at all other concentrations (range + 13.3%[4 mmol/l] − + 28.3%[1 mmol/l]). Regarding pipes without synovial fluid, mean Gd-DTPA SI at 2 mmol/l was 1275 ± 56au. Compared with Gd-BOPTA, SI was lower at 0.5 mmol/l (− 6.8%,P < 0.001), while it was higher (P < 0.001) at all other concentrations (range + 6.1%[4 mmol/l] − + 19.6% [1 mmol/l]). CONCLUSIONS: In vitro, Gd-BOPTA at 1 mmol/ had a + 28% SI increase in comparison to Gd-DTPA 2 mmol/l. SI similar to Gd-DTPA can be obtained using one fourth concentration of Gd-BOPTA. BioMed Central 2019-10-25 /pmc/articles/PMC6815038/ /pubmed/31653206 http://dx.doi.org/10.1186/s12880-019-0387-4 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Messina, Carmelo Albano, Domenico Orlandi, Davide Chianca, Vito Corazza, Angelo Ferrari, Federica Gitto, Salvatore Sconfienza, Luca Maria Potential use of a diluted high-relaxivity gadolinium-based intra-articular contrast agent for magnetic resonance arthrography: an in-vitro study |
title | Potential use of a diluted high-relaxivity gadolinium-based intra-articular contrast agent for magnetic resonance arthrography: an in-vitro study |
title_full | Potential use of a diluted high-relaxivity gadolinium-based intra-articular contrast agent for magnetic resonance arthrography: an in-vitro study |
title_fullStr | Potential use of a diluted high-relaxivity gadolinium-based intra-articular contrast agent for magnetic resonance arthrography: an in-vitro study |
title_full_unstemmed | Potential use of a diluted high-relaxivity gadolinium-based intra-articular contrast agent for magnetic resonance arthrography: an in-vitro study |
title_short | Potential use of a diluted high-relaxivity gadolinium-based intra-articular contrast agent for magnetic resonance arthrography: an in-vitro study |
title_sort | potential use of a diluted high-relaxivity gadolinium-based intra-articular contrast agent for magnetic resonance arthrography: an in-vitro study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6815038/ https://www.ncbi.nlm.nih.gov/pubmed/31653206 http://dx.doi.org/10.1186/s12880-019-0387-4 |
work_keys_str_mv | AT messinacarmelo potentialuseofadilutedhighrelaxivitygadoliniumbasedintraarticularcontrastagentformagneticresonancearthrographyaninvitrostudy AT albanodomenico potentialuseofadilutedhighrelaxivitygadoliniumbasedintraarticularcontrastagentformagneticresonancearthrographyaninvitrostudy AT orlandidavide potentialuseofadilutedhighrelaxivitygadoliniumbasedintraarticularcontrastagentformagneticresonancearthrographyaninvitrostudy AT chiancavito potentialuseofadilutedhighrelaxivitygadoliniumbasedintraarticularcontrastagentformagneticresonancearthrographyaninvitrostudy AT corazzaangelo potentialuseofadilutedhighrelaxivitygadoliniumbasedintraarticularcontrastagentformagneticresonancearthrographyaninvitrostudy AT ferrarifederica potentialuseofadilutedhighrelaxivitygadoliniumbasedintraarticularcontrastagentformagneticresonancearthrographyaninvitrostudy AT gittosalvatore potentialuseofadilutedhighrelaxivitygadoliniumbasedintraarticularcontrastagentformagneticresonancearthrographyaninvitrostudy AT sconfienzalucamaria potentialuseofadilutedhighrelaxivitygadoliniumbasedintraarticularcontrastagentformagneticresonancearthrographyaninvitrostudy |