Cargando…

Electric Endocut and Autocut Resection for Endoscopic Papillectomy: A Systematic Review

OBJECTIVE: Risks of bleeding and pancreatitis after mucosal resection using the purecut/autocut and blendcut/endocut modes for endoscopic papillectomy have not been fully clarified. Thus, a systematic review on electrosurgical cutting modes for endoscopic papillectomy was conducted focusing on the t...

Descripción completa

Detalles Bibliográficos
Autores principales: Minami, Kazuhiro, Iwasaki, Eisuke, Fukuhara, Seiichiro, Horibe, Masayasu, Seino, Takashi, Kawasaki, Shintaro, Katayama, Tadashi, Takimoto, Youichi, Tamagawa, Hiroki, Machida, Yujiro, Kanai, Takanori, Itoi, Takao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Society of Internal Medicine 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6815892/
https://www.ncbi.nlm.nih.gov/pubmed/31243201
http://dx.doi.org/10.2169/internalmedicine.2720-19
_version_ 1783463278670774272
author Minami, Kazuhiro
Iwasaki, Eisuke
Fukuhara, Seiichiro
Horibe, Masayasu
Seino, Takashi
Kawasaki, Shintaro
Katayama, Tadashi
Takimoto, Youichi
Tamagawa, Hiroki
Machida, Yujiro
Kanai, Takanori
Itoi, Takao
author_facet Minami, Kazuhiro
Iwasaki, Eisuke
Fukuhara, Seiichiro
Horibe, Masayasu
Seino, Takashi
Kawasaki, Shintaro
Katayama, Tadashi
Takimoto, Youichi
Tamagawa, Hiroki
Machida, Yujiro
Kanai, Takanori
Itoi, Takao
author_sort Minami, Kazuhiro
collection PubMed
description OBJECTIVE: Risks of bleeding and pancreatitis after mucosal resection using the purecut/autocut and blendcut/endocut modes for endoscopic papillectomy have not been fully clarified. Thus, a systematic review on electrosurgical cutting modes for endoscopic papillectomy was conducted focusing on the types and incidence of adverse events. METHODS: We searched the PubMed and Cochrane library for cases of endoscopic papillectomy recorded as of April 2017. Studies reporting the methods of electrically excising a tumor in the duodenal papilla and the number of adverse events were extracted. Studies were collected and examined separately based on the electrosurgical cutting mode, and the incidence rate for each adverse event was summarized. RESULTS: A total of 159 relevant articles were found; among them, 20 studies were included and 139 excluded. Five studies analyzed endoscopic papillectomy with the purecut/autocut mode and 16 with the blendcut/endocut mode. Only one study investigated both modes (purecut and endocut). With the purecut/autocut mode, the incidence of bleeding was 2.8-50%, and that of pancreatitis was 0-50% (mean: 12.8%). With the blendcut/endocut mode, the incidence of bleeding was 0-42.3%, and that of pancreatitis was 0%-17.9% (mean: 9.5%). CONCLUSION: Both methods had high adverse event rates for endoscopic papillectomy. Thus, a standard method of endoscopic papillectomy, including the electrosurgical cutting mode, needs to be established.
format Online
Article
Text
id pubmed-6815892
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Japanese Society of Internal Medicine
record_format MEDLINE/PubMed
spelling pubmed-68158922019-10-29 Electric Endocut and Autocut Resection for Endoscopic Papillectomy: A Systematic Review Minami, Kazuhiro Iwasaki, Eisuke Fukuhara, Seiichiro Horibe, Masayasu Seino, Takashi Kawasaki, Shintaro Katayama, Tadashi Takimoto, Youichi Tamagawa, Hiroki Machida, Yujiro Kanai, Takanori Itoi, Takao Intern Med Original Article OBJECTIVE: Risks of bleeding and pancreatitis after mucosal resection using the purecut/autocut and blendcut/endocut modes for endoscopic papillectomy have not been fully clarified. Thus, a systematic review on electrosurgical cutting modes for endoscopic papillectomy was conducted focusing on the types and incidence of adverse events. METHODS: We searched the PubMed and Cochrane library for cases of endoscopic papillectomy recorded as of April 2017. Studies reporting the methods of electrically excising a tumor in the duodenal papilla and the number of adverse events were extracted. Studies were collected and examined separately based on the electrosurgical cutting mode, and the incidence rate for each adverse event was summarized. RESULTS: A total of 159 relevant articles were found; among them, 20 studies were included and 139 excluded. Five studies analyzed endoscopic papillectomy with the purecut/autocut mode and 16 with the blendcut/endocut mode. Only one study investigated both modes (purecut and endocut). With the purecut/autocut mode, the incidence of bleeding was 2.8-50%, and that of pancreatitis was 0-50% (mean: 12.8%). With the blendcut/endocut mode, the incidence of bleeding was 0-42.3%, and that of pancreatitis was 0%-17.9% (mean: 9.5%). CONCLUSION: Both methods had high adverse event rates for endoscopic papillectomy. Thus, a standard method of endoscopic papillectomy, including the electrosurgical cutting mode, needs to be established. The Japanese Society of Internal Medicine 2019-06-27 2019-10-01 /pmc/articles/PMC6815892/ /pubmed/31243201 http://dx.doi.org/10.2169/internalmedicine.2720-19 Text en Copyright © 2019 by The Japanese Society of Internal Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/ The Internal Medicine is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Minami, Kazuhiro
Iwasaki, Eisuke
Fukuhara, Seiichiro
Horibe, Masayasu
Seino, Takashi
Kawasaki, Shintaro
Katayama, Tadashi
Takimoto, Youichi
Tamagawa, Hiroki
Machida, Yujiro
Kanai, Takanori
Itoi, Takao
Electric Endocut and Autocut Resection for Endoscopic Papillectomy: A Systematic Review
title Electric Endocut and Autocut Resection for Endoscopic Papillectomy: A Systematic Review
title_full Electric Endocut and Autocut Resection for Endoscopic Papillectomy: A Systematic Review
title_fullStr Electric Endocut and Autocut Resection for Endoscopic Papillectomy: A Systematic Review
title_full_unstemmed Electric Endocut and Autocut Resection for Endoscopic Papillectomy: A Systematic Review
title_short Electric Endocut and Autocut Resection for Endoscopic Papillectomy: A Systematic Review
title_sort electric endocut and autocut resection for endoscopic papillectomy: a systematic review
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6815892/
https://www.ncbi.nlm.nih.gov/pubmed/31243201
http://dx.doi.org/10.2169/internalmedicine.2720-19
work_keys_str_mv AT minamikazuhiro electricendocutandautocutresectionforendoscopicpapillectomyasystematicreview
AT iwasakieisuke electricendocutandautocutresectionforendoscopicpapillectomyasystematicreview
AT fukuharaseiichiro electricendocutandautocutresectionforendoscopicpapillectomyasystematicreview
AT horibemasayasu electricendocutandautocutresectionforendoscopicpapillectomyasystematicreview
AT seinotakashi electricendocutandautocutresectionforendoscopicpapillectomyasystematicreview
AT kawasakishintaro electricendocutandautocutresectionforendoscopicpapillectomyasystematicreview
AT katayamatadashi electricendocutandautocutresectionforendoscopicpapillectomyasystematicreview
AT takimotoyouichi electricendocutandautocutresectionforendoscopicpapillectomyasystematicreview
AT tamagawahiroki electricendocutandautocutresectionforendoscopicpapillectomyasystematicreview
AT machidayujiro electricendocutandautocutresectionforendoscopicpapillectomyasystematicreview
AT kanaitakanori electricendocutandautocutresectionforendoscopicpapillectomyasystematicreview
AT itoitakao electricendocutandautocutresectionforendoscopicpapillectomyasystematicreview