Cargando…

Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE)

BACKGROUND: 3D non-contrast high-resolution black-blood cardiovascular magnetic resonance (CMR) (DANTE-SPACE) has been used for surveillance of abdominal aortic aneurysm (AAA) and validated against computed tomography (CT) angiography. However, it requires a long scan time of more than 7 min. We sou...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Chengcheng, Cao, Lizhen, Wen, Zhaoying, Ahn, Sinyeob, Raithel, Esther, Forman, Christoph, Hope, Michael, Saloner, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6816154/
https://www.ncbi.nlm.nih.gov/pubmed/31660983
http://dx.doi.org/10.1186/s12968-019-0571-2
_version_ 1783463326229987328
author Zhu, Chengcheng
Cao, Lizhen
Wen, Zhaoying
Ahn, Sinyeob
Raithel, Esther
Forman, Christoph
Hope, Michael
Saloner, David
author_facet Zhu, Chengcheng
Cao, Lizhen
Wen, Zhaoying
Ahn, Sinyeob
Raithel, Esther
Forman, Christoph
Hope, Michael
Saloner, David
author_sort Zhu, Chengcheng
collection PubMed
description BACKGROUND: 3D non-contrast high-resolution black-blood cardiovascular magnetic resonance (CMR) (DANTE-SPACE) has been used for surveillance of abdominal aortic aneurysm (AAA) and validated against computed tomography (CT) angiography. However, it requires a long scan time of more than 7 min. We sought to develop an accelerated sequence applying compressed sensing (CS-DANTE-SPACE) and validate it in AAA patients undergoing surveillance. METHODS: Thirty-eight AAA patients (all males, 73 ± 6 years) under clinical surveillance were recruited for this study. All patients were scanned with DANTE-SPACE (scan time 7:10 min) and CS-DANTE-SPACE (scan time 4:12 min, a reduction of 41.4%). Nine 9 patients were scanned more than 2 times. In total, 50 pairs of images were available for comparison. Two radiologists independently evaluated the image quality on a 1–4 scale, and measured the maximal diameter of AAA, the intra-luminal thrombus (ILT) and lumen area, ILT-to-muscle signal intensity ratio, and the ILT-to-lumen contrast ratio. The sharpness of the aneurysm inner/outer boundaries was quantified. RESULTS: CS-DANTE-SPACE achieved comparable image quality compared with DANTE-SPACE (3.15 ± 0.67 vs. 3.03 ± 0.64, p = 0.06). There was excellent agreement between results from the two sequences for diameter/area and ILT ratio measurements (ICCs> 0.85), and for quantifying growth rate (3.3 ± 3.1 vs. 3.3 ± 3.4 mm/year, ICC = 0.95.) CS-DANTE-SPACE showed a higher ILT-to-lumen contrast ratio (p = 0.01) and higher sharpness than DANTE-SPACE (p = 0.002). Both sequences had excellent inter-reader reproducibility for quantitative measurements (ICC > 0.88). CONCLUSION: CS-DANTE-SPACE can reduce scan time while maintaining image quality for AAA imaging. It is a promising tool for the surveillance of patients with AAA disease in the clinical setting. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12968-019-0571-2) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6816154
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-68161542019-10-31 Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE) Zhu, Chengcheng Cao, Lizhen Wen, Zhaoying Ahn, Sinyeob Raithel, Esther Forman, Christoph Hope, Michael Saloner, David J Cardiovasc Magn Reson Technical Notes BACKGROUND: 3D non-contrast high-resolution black-blood cardiovascular magnetic resonance (CMR) (DANTE-SPACE) has been used for surveillance of abdominal aortic aneurysm (AAA) and validated against computed tomography (CT) angiography. However, it requires a long scan time of more than 7 min. We sought to develop an accelerated sequence applying compressed sensing (CS-DANTE-SPACE) and validate it in AAA patients undergoing surveillance. METHODS: Thirty-eight AAA patients (all males, 73 ± 6 years) under clinical surveillance were recruited for this study. All patients were scanned with DANTE-SPACE (scan time 7:10 min) and CS-DANTE-SPACE (scan time 4:12 min, a reduction of 41.4%). Nine 9 patients were scanned more than 2 times. In total, 50 pairs of images were available for comparison. Two radiologists independently evaluated the image quality on a 1–4 scale, and measured the maximal diameter of AAA, the intra-luminal thrombus (ILT) and lumen area, ILT-to-muscle signal intensity ratio, and the ILT-to-lumen contrast ratio. The sharpness of the aneurysm inner/outer boundaries was quantified. RESULTS: CS-DANTE-SPACE achieved comparable image quality compared with DANTE-SPACE (3.15 ± 0.67 vs. 3.03 ± 0.64, p = 0.06). There was excellent agreement between results from the two sequences for diameter/area and ILT ratio measurements (ICCs> 0.85), and for quantifying growth rate (3.3 ± 3.1 vs. 3.3 ± 3.4 mm/year, ICC = 0.95.) CS-DANTE-SPACE showed a higher ILT-to-lumen contrast ratio (p = 0.01) and higher sharpness than DANTE-SPACE (p = 0.002). Both sequences had excellent inter-reader reproducibility for quantitative measurements (ICC > 0.88). CONCLUSION: CS-DANTE-SPACE can reduce scan time while maintaining image quality for AAA imaging. It is a promising tool for the surveillance of patients with AAA disease in the clinical setting. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12968-019-0571-2) contains supplementary material, which is available to authorized users. BioMed Central 2019-10-28 /pmc/articles/PMC6816154/ /pubmed/31660983 http://dx.doi.org/10.1186/s12968-019-0571-2 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Technical Notes
Zhu, Chengcheng
Cao, Lizhen
Wen, Zhaoying
Ahn, Sinyeob
Raithel, Esther
Forman, Christoph
Hope, Michael
Saloner, David
Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE)
title Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE)
title_full Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE)
title_fullStr Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE)
title_full_unstemmed Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE)
title_short Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE)
title_sort surveillance of abdominal aortic aneurysm using accelerated 3d non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (cs-dante-space)
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6816154/
https://www.ncbi.nlm.nih.gov/pubmed/31660983
http://dx.doi.org/10.1186/s12968-019-0571-2
work_keys_str_mv AT zhuchengcheng surveillanceofabdominalaorticaneurysmusingaccelerated3dnoncontrastblackbloodcardiovascularmagneticresonancewithcompressedsensingcsdantespace
AT caolizhen surveillanceofabdominalaorticaneurysmusingaccelerated3dnoncontrastblackbloodcardiovascularmagneticresonancewithcompressedsensingcsdantespace
AT wenzhaoying surveillanceofabdominalaorticaneurysmusingaccelerated3dnoncontrastblackbloodcardiovascularmagneticresonancewithcompressedsensingcsdantespace
AT ahnsinyeob surveillanceofabdominalaorticaneurysmusingaccelerated3dnoncontrastblackbloodcardiovascularmagneticresonancewithcompressedsensingcsdantespace
AT raithelesther surveillanceofabdominalaorticaneurysmusingaccelerated3dnoncontrastblackbloodcardiovascularmagneticresonancewithcompressedsensingcsdantespace
AT formanchristoph surveillanceofabdominalaorticaneurysmusingaccelerated3dnoncontrastblackbloodcardiovascularmagneticresonancewithcompressedsensingcsdantespace
AT hopemichael surveillanceofabdominalaorticaneurysmusingaccelerated3dnoncontrastblackbloodcardiovascularmagneticresonancewithcompressedsensingcsdantespace
AT salonerdavid surveillanceofabdominalaorticaneurysmusingaccelerated3dnoncontrastblackbloodcardiovascularmagneticresonancewithcompressedsensingcsdantespace