Cargando…
Use of ultrasound-measured internal jugular vein collapsibility index to determine static intracardiac pressures in patients with presumed pulmonary hypertension
BACKGROUND: Bedside ultrasound helps to estimate volume status in critically ill patients and has traditionally relied on diameter, respiratory variation, and collapsibility of the inferior vena cava (IVC) to reflect fluid status. We evaluated collapsibility of the internal jugular vein (IJ) with ul...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6816682/ https://www.ncbi.nlm.nih.gov/pubmed/31659483 http://dx.doi.org/10.1186/s13613-019-0595-7 |
_version_ | 1783463397704073216 |
---|---|
author | Parikh, Raj Spring, Matthew Weinberg, Janice Reardon, Christine C. Farber, Harrison W. |
author_facet | Parikh, Raj Spring, Matthew Weinberg, Janice Reardon, Christine C. Farber, Harrison W. |
author_sort | Parikh, Raj |
collection | PubMed |
description | BACKGROUND: Bedside ultrasound helps to estimate volume status in critically ill patients and has traditionally relied on diameter, respiratory variation, and collapsibility of the inferior vena cava (IVC) to reflect fluid status. We evaluated collapsibility of the internal jugular vein (IJ) with ultrasound and correlated it with concomitant right heart catheterization (RHC) measurements in patients with presumed pulmonary hypertension. METHODS AND RESULTS: We studied 71 patients undergoing RHC for evaluation of pulmonary hypertension. Using two-dimensional ultrasound (Sonosite, Washington, USA), we measured the diameter of the IJ at rest, during respiratory variation, and during manual compression. Collapsibility index during respiration (respiratory CI) and during manual compression (compression CI) was calculated. We correlated mean right atrial pressure (mRAP) and pulmonary artery occlusion pressure (PAOP) defined by RHC measurements with respiratory and compression CI. A secondary goal was examining correlations between CI calculations and B-type natriuretic peptide (BNP) levels. Baseline characteristics demonstrated female predominance (n = 51; 71.8%), mean age 59.5 years, and BMI 27.3. There were significant correlations between decrease in compression CI and increase in both mRAP (Spearman: − 0.43; p value = 0.0002) and PAOP (Spearman: − 0.35; p value = 0.0027). In contrast, there was no significant correlation between respiratory CI and either mRAP (Spearman: − 0.14; p value = 0.35) or PAOP (Spearman:− 0.12; p value = 0.31). We also observed significant negative correlation between compression CI and BNP (Spearman: − 0.31; p value = 0.01) but not between respiratory CI and BNP (Spearman: − 0.12; p value = 0.35). CONCLUSION: Increasing use of ultrasound has led to innovative techniques for estimating volume status. While prior ultrasound studies have used clinical parameters to estimate fluid status, our study used RHC measurements and demonstrated that compression CI potentially reflects directly measured mRAP and PAOP. |
format | Online Article Text |
id | pubmed-6816682 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-68166822019-11-12 Use of ultrasound-measured internal jugular vein collapsibility index to determine static intracardiac pressures in patients with presumed pulmonary hypertension Parikh, Raj Spring, Matthew Weinberg, Janice Reardon, Christine C. Farber, Harrison W. Ann Intensive Care Research BACKGROUND: Bedside ultrasound helps to estimate volume status in critically ill patients and has traditionally relied on diameter, respiratory variation, and collapsibility of the inferior vena cava (IVC) to reflect fluid status. We evaluated collapsibility of the internal jugular vein (IJ) with ultrasound and correlated it with concomitant right heart catheterization (RHC) measurements in patients with presumed pulmonary hypertension. METHODS AND RESULTS: We studied 71 patients undergoing RHC for evaluation of pulmonary hypertension. Using two-dimensional ultrasound (Sonosite, Washington, USA), we measured the diameter of the IJ at rest, during respiratory variation, and during manual compression. Collapsibility index during respiration (respiratory CI) and during manual compression (compression CI) was calculated. We correlated mean right atrial pressure (mRAP) and pulmonary artery occlusion pressure (PAOP) defined by RHC measurements with respiratory and compression CI. A secondary goal was examining correlations between CI calculations and B-type natriuretic peptide (BNP) levels. Baseline characteristics demonstrated female predominance (n = 51; 71.8%), mean age 59.5 years, and BMI 27.3. There were significant correlations between decrease in compression CI and increase in both mRAP (Spearman: − 0.43; p value = 0.0002) and PAOP (Spearman: − 0.35; p value = 0.0027). In contrast, there was no significant correlation between respiratory CI and either mRAP (Spearman: − 0.14; p value = 0.35) or PAOP (Spearman:− 0.12; p value = 0.31). We also observed significant negative correlation between compression CI and BNP (Spearman: − 0.31; p value = 0.01) but not between respiratory CI and BNP (Spearman: − 0.12; p value = 0.35). CONCLUSION: Increasing use of ultrasound has led to innovative techniques for estimating volume status. While prior ultrasound studies have used clinical parameters to estimate fluid status, our study used RHC measurements and demonstrated that compression CI potentially reflects directly measured mRAP and PAOP. Springer International Publishing 2019-10-28 /pmc/articles/PMC6816682/ /pubmed/31659483 http://dx.doi.org/10.1186/s13613-019-0595-7 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Parikh, Raj Spring, Matthew Weinberg, Janice Reardon, Christine C. Farber, Harrison W. Use of ultrasound-measured internal jugular vein collapsibility index to determine static intracardiac pressures in patients with presumed pulmonary hypertension |
title | Use of ultrasound-measured internal jugular vein collapsibility index to determine static intracardiac pressures in patients with presumed pulmonary hypertension |
title_full | Use of ultrasound-measured internal jugular vein collapsibility index to determine static intracardiac pressures in patients with presumed pulmonary hypertension |
title_fullStr | Use of ultrasound-measured internal jugular vein collapsibility index to determine static intracardiac pressures in patients with presumed pulmonary hypertension |
title_full_unstemmed | Use of ultrasound-measured internal jugular vein collapsibility index to determine static intracardiac pressures in patients with presumed pulmonary hypertension |
title_short | Use of ultrasound-measured internal jugular vein collapsibility index to determine static intracardiac pressures in patients with presumed pulmonary hypertension |
title_sort | use of ultrasound-measured internal jugular vein collapsibility index to determine static intracardiac pressures in patients with presumed pulmonary hypertension |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6816682/ https://www.ncbi.nlm.nih.gov/pubmed/31659483 http://dx.doi.org/10.1186/s13613-019-0595-7 |
work_keys_str_mv | AT parikhraj useofultrasoundmeasuredinternaljugularveincollapsibilityindextodeterminestaticintracardiacpressuresinpatientswithpresumedpulmonaryhypertension AT springmatthew useofultrasoundmeasuredinternaljugularveincollapsibilityindextodeterminestaticintracardiacpressuresinpatientswithpresumedpulmonaryhypertension AT weinbergjanice useofultrasoundmeasuredinternaljugularveincollapsibilityindextodeterminestaticintracardiacpressuresinpatientswithpresumedpulmonaryhypertension AT reardonchristinec useofultrasoundmeasuredinternaljugularveincollapsibilityindextodeterminestaticintracardiacpressuresinpatientswithpresumedpulmonaryhypertension AT farberharrisonw useofultrasoundmeasuredinternaljugularveincollapsibilityindextodeterminestaticintracardiacpressuresinpatientswithpresumedpulmonaryhypertension |