Cargando…
Initial Clinical Experience Treating Patients with Breast Cancer on a 6-MV Flattening-Filter-Free O-Ring Linear Accelerator
PURPOSE: Three-dimensional (3D) conformal radiation therapy is the standard technique used for adjuvant breast radiation. We report the clinical use of a novel 6-MV flattening-filter-free O-ring linear accelerator (6X-FFF ORL) for breast cancer that may improve upon 3D conformal radiation therapy wi...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6817541/ https://www.ncbi.nlm.nih.gov/pubmed/31673650 http://dx.doi.org/10.1016/j.adro.2019.05.006 |
_version_ | 1783463442906087424 |
---|---|
author | Barsky, Andrew R. O'Grady, Fionnbarr Kennedy, Christopher Taunk, Neil K. Dong, Lei Metz, James M. Li, Taoran Freedman, Gary M. |
author_facet | Barsky, Andrew R. O'Grady, Fionnbarr Kennedy, Christopher Taunk, Neil K. Dong, Lei Metz, James M. Li, Taoran Freedman, Gary M. |
author_sort | Barsky, Andrew R. |
collection | PubMed |
description | PURPOSE: Three-dimensional (3D) conformal radiation therapy is the standard technique used for adjuvant breast radiation. We report the clinical use of a novel 6-MV flattening-filter-free O-ring linear accelerator (6X-FFF ORL) for breast cancer that may improve upon 3D conformal radiation therapy with its higher dose rate and faster rotation and leaf speed than traditional C-arm gantries. METHODS AND MATERIALS: We retrospectively identified consecutive women with breast cancer who underwent surgery followed by radiation therapy to the breast or chest wall on Halcyon (Varian Medical Systems, Palo Alto, CA), a novel 6X-FFF ORL. We report their clinicopathologic information, radiation therapy details, acute toxicities, dose-volume histogram data, couch corrections, and treatment times. RESULTS: Thirty-four women were treated for breast cancer on a 6X-FFF ORL between February 2018 and September 2018. All patients underwent lumpectomy (92%) or mastectomy (8%). Tumors were left sided in 44% and bilateral in 9%, and 9% included comprehensive nodal radiation therapy. Twelve percent of patients were treated prone and 29% with deep-inspiration breath hold. Standard target and normal-tissue constraints were met in nearly all plans. The 3D vector couch correction average was 0.77 ± 0.05 cm. The mean beam-on time was 2.0 ± 0.3 minutes, and mean treatment time from start of imaging to beam-off was 4.4 ± 0.4 minutes. Grade 2 dermatitis, fatigue, and breast pain occurred in 18%, 9%, and 3% of patients, respectively. CONCLUSIONS: In this first clinical report of breast radiation therapy with a 6X-FFF ORL, treatment was versatile and fast for complex setups and techniques, with acceptable toxicity and organ-at-risk doses. Thus, a 6X-FFF ORL can increase throughput or reduce length of day compared with a conventional C-arm linear accelerator in departments with a busy breast service. |
format | Online Article Text |
id | pubmed-6817541 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-68175412019-10-31 Initial Clinical Experience Treating Patients with Breast Cancer on a 6-MV Flattening-Filter-Free O-Ring Linear Accelerator Barsky, Andrew R. O'Grady, Fionnbarr Kennedy, Christopher Taunk, Neil K. Dong, Lei Metz, James M. Li, Taoran Freedman, Gary M. Adv Radiat Oncol Breast Cancer PURPOSE: Three-dimensional (3D) conformal radiation therapy is the standard technique used for adjuvant breast radiation. We report the clinical use of a novel 6-MV flattening-filter-free O-ring linear accelerator (6X-FFF ORL) for breast cancer that may improve upon 3D conformal radiation therapy with its higher dose rate and faster rotation and leaf speed than traditional C-arm gantries. METHODS AND MATERIALS: We retrospectively identified consecutive women with breast cancer who underwent surgery followed by radiation therapy to the breast or chest wall on Halcyon (Varian Medical Systems, Palo Alto, CA), a novel 6X-FFF ORL. We report their clinicopathologic information, radiation therapy details, acute toxicities, dose-volume histogram data, couch corrections, and treatment times. RESULTS: Thirty-four women were treated for breast cancer on a 6X-FFF ORL between February 2018 and September 2018. All patients underwent lumpectomy (92%) or mastectomy (8%). Tumors were left sided in 44% and bilateral in 9%, and 9% included comprehensive nodal radiation therapy. Twelve percent of patients were treated prone and 29% with deep-inspiration breath hold. Standard target and normal-tissue constraints were met in nearly all plans. The 3D vector couch correction average was 0.77 ± 0.05 cm. The mean beam-on time was 2.0 ± 0.3 minutes, and mean treatment time from start of imaging to beam-off was 4.4 ± 0.4 minutes. Grade 2 dermatitis, fatigue, and breast pain occurred in 18%, 9%, and 3% of patients, respectively. CONCLUSIONS: In this first clinical report of breast radiation therapy with a 6X-FFF ORL, treatment was versatile and fast for complex setups and techniques, with acceptable toxicity and organ-at-risk doses. Thus, a 6X-FFF ORL can increase throughput or reduce length of day compared with a conventional C-arm linear accelerator in departments with a busy breast service. Elsevier 2019-06-08 /pmc/articles/PMC6817541/ /pubmed/31673650 http://dx.doi.org/10.1016/j.adro.2019.05.006 Text en © 2019 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Breast Cancer Barsky, Andrew R. O'Grady, Fionnbarr Kennedy, Christopher Taunk, Neil K. Dong, Lei Metz, James M. Li, Taoran Freedman, Gary M. Initial Clinical Experience Treating Patients with Breast Cancer on a 6-MV Flattening-Filter-Free O-Ring Linear Accelerator |
title | Initial Clinical Experience Treating Patients with Breast Cancer on a 6-MV Flattening-Filter-Free O-Ring Linear Accelerator |
title_full | Initial Clinical Experience Treating Patients with Breast Cancer on a 6-MV Flattening-Filter-Free O-Ring Linear Accelerator |
title_fullStr | Initial Clinical Experience Treating Patients with Breast Cancer on a 6-MV Flattening-Filter-Free O-Ring Linear Accelerator |
title_full_unstemmed | Initial Clinical Experience Treating Patients with Breast Cancer on a 6-MV Flattening-Filter-Free O-Ring Linear Accelerator |
title_short | Initial Clinical Experience Treating Patients with Breast Cancer on a 6-MV Flattening-Filter-Free O-Ring Linear Accelerator |
title_sort | initial clinical experience treating patients with breast cancer on a 6-mv flattening-filter-free o-ring linear accelerator |
topic | Breast Cancer |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6817541/ https://www.ncbi.nlm.nih.gov/pubmed/31673650 http://dx.doi.org/10.1016/j.adro.2019.05.006 |
work_keys_str_mv | AT barskyandrewr initialclinicalexperiencetreatingpatientswithbreastcancerona6mvflatteningfilterfreeoringlinearaccelerator AT ogradyfionnbarr initialclinicalexperiencetreatingpatientswithbreastcancerona6mvflatteningfilterfreeoringlinearaccelerator AT kennedychristopher initialclinicalexperiencetreatingpatientswithbreastcancerona6mvflatteningfilterfreeoringlinearaccelerator AT taunkneilk initialclinicalexperiencetreatingpatientswithbreastcancerona6mvflatteningfilterfreeoringlinearaccelerator AT donglei initialclinicalexperiencetreatingpatientswithbreastcancerona6mvflatteningfilterfreeoringlinearaccelerator AT metzjamesm initialclinicalexperiencetreatingpatientswithbreastcancerona6mvflatteningfilterfreeoringlinearaccelerator AT litaoran initialclinicalexperiencetreatingpatientswithbreastcancerona6mvflatteningfilterfreeoringlinearaccelerator AT freedmangarym initialclinicalexperiencetreatingpatientswithbreastcancerona6mvflatteningfilterfreeoringlinearaccelerator |