Safety Profile of the New Harmonic Focus: Different Emissivity and Temperature Behavior Between the Active and the Inactive Blade
Ultrasonic devices disperse less energy in the tissues. The new Harmonic Focus+ (HF+) seems to be more efficient but thermal damages have been reported. This study examined the temperature and the emissivity profile of the active and passive blades of the HF+, on a pig tissue model at different powe...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6818976/ https://www.ncbi.nlm.nih.gov/pubmed/31453911 http://dx.doi.org/10.1097/SLE.0000000000000712 |
_version_ | 1783463657957490688 |
---|---|
author | Latteri, Saverio Stella, Giuseppe Gueli, Anna M. Mazzaglia, Stefania Palumbo, Valentina Guastella, Tommaso |
author_facet | Latteri, Saverio Stella, Giuseppe Gueli, Anna M. Mazzaglia, Stefania Palumbo, Valentina Guastella, Tommaso |
author_sort | Latteri, Saverio |
collection | PubMed |
description | Ultrasonic devices disperse less energy in the tissues. The new Harmonic Focus+ (HF+) seems to be more efficient but thermal damages have been reported. This study examined the temperature and the emissivity profile of the active and passive blades of the HF+, on a pig tissue model at different power settings. The FLIR System B series thermal imaging camera has been used on various biological pig tissues to evaluate the emissivity of the ultrasonic device. The active blade heats up faster than the passive one and the increase in power increases the speed of the temperature raising only on the active blade. Increasing the power setting reduces the dissection time and the temperature of both blades. Active blade temperatures of <60°C are obtained with cutting times close to 5 seconds; with these cutting times, the inactive blade does not exceed 30°C. The HF+ emissivity profiles demonstrate that the behavior of the inactive blade is significantly different from the active one. To prevent thermal damages, keep the active blade toward the operator, do not exceed 5 seconds of activation, use the maximum power, and avoid the use of the instrument as a dissector immediately after its activation. |
format | Online Article Text |
id | pubmed-6818976 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-68189762019-11-26 Safety Profile of the New Harmonic Focus: Different Emissivity and Temperature Behavior Between the Active and the Inactive Blade Latteri, Saverio Stella, Giuseppe Gueli, Anna M. Mazzaglia, Stefania Palumbo, Valentina Guastella, Tommaso Surg Laparosc Endosc Percutan Tech Online Articles: Technical Reports Ultrasonic devices disperse less energy in the tissues. The new Harmonic Focus+ (HF+) seems to be more efficient but thermal damages have been reported. This study examined the temperature and the emissivity profile of the active and passive blades of the HF+, on a pig tissue model at different power settings. The FLIR System B series thermal imaging camera has been used on various biological pig tissues to evaluate the emissivity of the ultrasonic device. The active blade heats up faster than the passive one and the increase in power increases the speed of the temperature raising only on the active blade. Increasing the power setting reduces the dissection time and the temperature of both blades. Active blade temperatures of <60°C are obtained with cutting times close to 5 seconds; with these cutting times, the inactive blade does not exceed 30°C. The HF+ emissivity profiles demonstrate that the behavior of the inactive blade is significantly different from the active one. To prevent thermal damages, keep the active blade toward the operator, do not exceed 5 seconds of activation, use the maximum power, and avoid the use of the instrument as a dissector immediately after its activation. Lippincott Williams & Wilkins 2019-10 2019-10-06 /pmc/articles/PMC6818976/ /pubmed/31453911 http://dx.doi.org/10.1097/SLE.0000000000000712 Text en Copyright © 2019 The Author(s). Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ |
spellingShingle | Online Articles: Technical Reports Latteri, Saverio Stella, Giuseppe Gueli, Anna M. Mazzaglia, Stefania Palumbo, Valentina Guastella, Tommaso Safety Profile of the New Harmonic Focus: Different Emissivity and Temperature Behavior Between the Active and the Inactive Blade |
title | Safety Profile of the New Harmonic Focus: Different Emissivity and Temperature Behavior Between the Active and the Inactive Blade |
title_full | Safety Profile of the New Harmonic Focus: Different Emissivity and Temperature Behavior Between the Active and the Inactive Blade |
title_fullStr | Safety Profile of the New Harmonic Focus: Different Emissivity and Temperature Behavior Between the Active and the Inactive Blade |
title_full_unstemmed | Safety Profile of the New Harmonic Focus: Different Emissivity and Temperature Behavior Between the Active and the Inactive Blade |
title_short | Safety Profile of the New Harmonic Focus: Different Emissivity and Temperature Behavior Between the Active and the Inactive Blade |
title_sort | safety profile of the new harmonic focus: different emissivity and temperature behavior between the active and the inactive blade |
topic | Online Articles: Technical Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6818976/ https://www.ncbi.nlm.nih.gov/pubmed/31453911 http://dx.doi.org/10.1097/SLE.0000000000000712 |
work_keys_str_mv | AT latterisaverio safetyprofileofthenewharmonicfocusdifferentemissivityandtemperaturebehaviorbetweentheactiveandtheinactiveblade AT stellagiuseppe safetyprofileofthenewharmonicfocusdifferentemissivityandtemperaturebehaviorbetweentheactiveandtheinactiveblade AT gueliannam safetyprofileofthenewharmonicfocusdifferentemissivityandtemperaturebehaviorbetweentheactiveandtheinactiveblade AT mazzagliastefania safetyprofileofthenewharmonicfocusdifferentemissivityandtemperaturebehaviorbetweentheactiveandtheinactiveblade AT palumbovalentina safetyprofileofthenewharmonicfocusdifferentemissivityandtemperaturebehaviorbetweentheactiveandtheinactiveblade AT guastellatommaso safetyprofileofthenewharmonicfocusdifferentemissivityandtemperaturebehaviorbetweentheactiveandtheinactiveblade |