Cargando…

Comparison of Superior‐Level Facet Joint Violations Between Robot‐Assisted Percutaneous Pedicle Screw Placement and Conventional Open Fluoroscopic‐Guided Pedicle Screw Placement

OBJECTIVE: To compare the superior‐level facet joint violations (FJV) between robot‐assisted (RA) percutaneous pedicle screw placement and conventional open fluoroscopic‐guided (FG) pedicle screw placement in a prospective cohort study. METHODS: This was a prospective cohort study without randomizat...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Qi, Xu, Yun‐Feng, Tian, Wei, Le, Xiao‐Feng, Liu, Bo, Liu, Ya‐Jun, He, Da, Sun, Yu‐Qin, Yuan, Qiang, Lang, Zhao, Han, Xiao‐Guang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons Australia, Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6819175/
https://www.ncbi.nlm.nih.gov/pubmed/31663290
http://dx.doi.org/10.1111/os.12534
_version_ 1783463684596563968
author Zhang, Qi
Xu, Yun‐Feng
Tian, Wei
Le, Xiao‐Feng
Liu, Bo
Liu, Ya‐Jun
He, Da
Sun, Yu‐Qin
Yuan, Qiang
Lang, Zhao
Han, Xiao‐Guang
author_facet Zhang, Qi
Xu, Yun‐Feng
Tian, Wei
Le, Xiao‐Feng
Liu, Bo
Liu, Ya‐Jun
He, Da
Sun, Yu‐Qin
Yuan, Qiang
Lang, Zhao
Han, Xiao‐Guang
author_sort Zhang, Qi
collection PubMed
description OBJECTIVE: To compare the superior‐level facet joint violations (FJV) between robot‐assisted (RA) percutaneous pedicle screw placement and conventional open fluoroscopic‐guided (FG) pedicle screw placement in a prospective cohort study. METHODS: This was a prospective cohort study without randomization. One‐hundred patients scheduled to undergo RA (n = 50) or FG (n = 50) transforaminal lumbar interbody fusion were included from February 2016 to May 2018. The grade of FJV, the distance between pedicle screws and the corresponding proximal facet joint, and intra‐pedicle accuracy of the top screw were evaluated based on postoperative CT scan. Patient demographics, perioperative outcomes, and radiation exposure were recorded and compared. Perioperative outcomes include surgical time, intraoperative blood loss, postoperative length of stay, conversion, and revision surgeries. RESULTS: Of the 100 screws in the RA group, 4 violated the proximal facet joint, while 26 of 100 in the FG group had FJV (P = 0.000). In the RA group, 3 and 1 screws were classified as grade 1 and 2, respectively. Of the 26 FJV screws in the FG group, 17 screws were scored as grade 1, 6 screws were grade 2, and 3 screws were grade 3. Significantly more severe FJV were noted in the FG group than in the RA group (P = 0.000). There was a statistically significant difference between RA and FG for overall violation grade (0.05 vs 0.38, P = 0.000). The average distance of pedicle screws from facet joints in the RA group (4.16 ± 2.60 mm) was larger than that in the FG group (1.92 ± 1.55 mm; P = 0.000). For intra‐pedicle accuracy, the rate of perfect screw position was greater in the RA group than in the FG group (85% vs 71%; P = 0.017). No statistically significant difference was found between the clinically acceptable screws between groups (P = 0.279). The radiation dose was higher in the FG group (30.3 ± 11.3 vs 65.3 ± 28.3 μSv; P = 0.000). The operative time in the RA group was significantly longer (184.7 ± 54.3 vs 117.8 ± 36.9 min; P = 0.000). CONCLUSIONS: Compared to the open FG technique, minimally invasive RA spine surgery was associated with fewer proximal facet joint violations, larger facet to screw distance, and higher intra‐pedicle accuracy.
format Online
Article
Text
id pubmed-6819175
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley & Sons Australia, Ltd
record_format MEDLINE/PubMed
spelling pubmed-68191752019-11-04 Comparison of Superior‐Level Facet Joint Violations Between Robot‐Assisted Percutaneous Pedicle Screw Placement and Conventional Open Fluoroscopic‐Guided Pedicle Screw Placement Zhang, Qi Xu, Yun‐Feng Tian, Wei Le, Xiao‐Feng Liu, Bo Liu, Ya‐Jun He, Da Sun, Yu‐Qin Yuan, Qiang Lang, Zhao Han, Xiao‐Guang Orthop Surg Clinical Articles OBJECTIVE: To compare the superior‐level facet joint violations (FJV) between robot‐assisted (RA) percutaneous pedicle screw placement and conventional open fluoroscopic‐guided (FG) pedicle screw placement in a prospective cohort study. METHODS: This was a prospective cohort study without randomization. One‐hundred patients scheduled to undergo RA (n = 50) or FG (n = 50) transforaminal lumbar interbody fusion were included from February 2016 to May 2018. The grade of FJV, the distance between pedicle screws and the corresponding proximal facet joint, and intra‐pedicle accuracy of the top screw were evaluated based on postoperative CT scan. Patient demographics, perioperative outcomes, and radiation exposure were recorded and compared. Perioperative outcomes include surgical time, intraoperative blood loss, postoperative length of stay, conversion, and revision surgeries. RESULTS: Of the 100 screws in the RA group, 4 violated the proximal facet joint, while 26 of 100 in the FG group had FJV (P = 0.000). In the RA group, 3 and 1 screws were classified as grade 1 and 2, respectively. Of the 26 FJV screws in the FG group, 17 screws were scored as grade 1, 6 screws were grade 2, and 3 screws were grade 3. Significantly more severe FJV were noted in the FG group than in the RA group (P = 0.000). There was a statistically significant difference between RA and FG for overall violation grade (0.05 vs 0.38, P = 0.000). The average distance of pedicle screws from facet joints in the RA group (4.16 ± 2.60 mm) was larger than that in the FG group (1.92 ± 1.55 mm; P = 0.000). For intra‐pedicle accuracy, the rate of perfect screw position was greater in the RA group than in the FG group (85% vs 71%; P = 0.017). No statistically significant difference was found between the clinically acceptable screws between groups (P = 0.279). The radiation dose was higher in the FG group (30.3 ± 11.3 vs 65.3 ± 28.3 μSv; P = 0.000). The operative time in the RA group was significantly longer (184.7 ± 54.3 vs 117.8 ± 36.9 min; P = 0.000). CONCLUSIONS: Compared to the open FG technique, minimally invasive RA spine surgery was associated with fewer proximal facet joint violations, larger facet to screw distance, and higher intra‐pedicle accuracy. John Wiley & Sons Australia, Ltd 2019-10-29 /pmc/articles/PMC6819175/ /pubmed/31663290 http://dx.doi.org/10.1111/os.12534 Text en © 2019 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Clinical Articles
Zhang, Qi
Xu, Yun‐Feng
Tian, Wei
Le, Xiao‐Feng
Liu, Bo
Liu, Ya‐Jun
He, Da
Sun, Yu‐Qin
Yuan, Qiang
Lang, Zhao
Han, Xiao‐Guang
Comparison of Superior‐Level Facet Joint Violations Between Robot‐Assisted Percutaneous Pedicle Screw Placement and Conventional Open Fluoroscopic‐Guided Pedicle Screw Placement
title Comparison of Superior‐Level Facet Joint Violations Between Robot‐Assisted Percutaneous Pedicle Screw Placement and Conventional Open Fluoroscopic‐Guided Pedicle Screw Placement
title_full Comparison of Superior‐Level Facet Joint Violations Between Robot‐Assisted Percutaneous Pedicle Screw Placement and Conventional Open Fluoroscopic‐Guided Pedicle Screw Placement
title_fullStr Comparison of Superior‐Level Facet Joint Violations Between Robot‐Assisted Percutaneous Pedicle Screw Placement and Conventional Open Fluoroscopic‐Guided Pedicle Screw Placement
title_full_unstemmed Comparison of Superior‐Level Facet Joint Violations Between Robot‐Assisted Percutaneous Pedicle Screw Placement and Conventional Open Fluoroscopic‐Guided Pedicle Screw Placement
title_short Comparison of Superior‐Level Facet Joint Violations Between Robot‐Assisted Percutaneous Pedicle Screw Placement and Conventional Open Fluoroscopic‐Guided Pedicle Screw Placement
title_sort comparison of superior‐level facet joint violations between robot‐assisted percutaneous pedicle screw placement and conventional open fluoroscopic‐guided pedicle screw placement
topic Clinical Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6819175/
https://www.ncbi.nlm.nih.gov/pubmed/31663290
http://dx.doi.org/10.1111/os.12534
work_keys_str_mv AT zhangqi comparisonofsuperiorlevelfacetjointviolationsbetweenrobotassistedpercutaneouspediclescrewplacementandconventionalopenfluoroscopicguidedpediclescrewplacement
AT xuyunfeng comparisonofsuperiorlevelfacetjointviolationsbetweenrobotassistedpercutaneouspediclescrewplacementandconventionalopenfluoroscopicguidedpediclescrewplacement
AT tianwei comparisonofsuperiorlevelfacetjointviolationsbetweenrobotassistedpercutaneouspediclescrewplacementandconventionalopenfluoroscopicguidedpediclescrewplacement
AT lexiaofeng comparisonofsuperiorlevelfacetjointviolationsbetweenrobotassistedpercutaneouspediclescrewplacementandconventionalopenfluoroscopicguidedpediclescrewplacement
AT liubo comparisonofsuperiorlevelfacetjointviolationsbetweenrobotassistedpercutaneouspediclescrewplacementandconventionalopenfluoroscopicguidedpediclescrewplacement
AT liuyajun comparisonofsuperiorlevelfacetjointviolationsbetweenrobotassistedpercutaneouspediclescrewplacementandconventionalopenfluoroscopicguidedpediclescrewplacement
AT heda comparisonofsuperiorlevelfacetjointviolationsbetweenrobotassistedpercutaneouspediclescrewplacementandconventionalopenfluoroscopicguidedpediclescrewplacement
AT sunyuqin comparisonofsuperiorlevelfacetjointviolationsbetweenrobotassistedpercutaneouspediclescrewplacementandconventionalopenfluoroscopicguidedpediclescrewplacement
AT yuanqiang comparisonofsuperiorlevelfacetjointviolationsbetweenrobotassistedpercutaneouspediclescrewplacementandconventionalopenfluoroscopicguidedpediclescrewplacement
AT langzhao comparisonofsuperiorlevelfacetjointviolationsbetweenrobotassistedpercutaneouspediclescrewplacementandconventionalopenfluoroscopicguidedpediclescrewplacement
AT hanxiaoguang comparisonofsuperiorlevelfacetjointviolationsbetweenrobotassistedpercutaneouspediclescrewplacementandconventionalopenfluoroscopicguidedpediclescrewplacement