Arthroscopic fixation of a greater tuberosity (GT) avulsion fracture by suture bridge repair has been described in several articles. However, all of them have used arthroscopic fixation of a small sized GT fracture fragment or have not used purely arthroscopic techniques. In this Technical Note, the...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Dong Ryul, Noh, Young-Min, Lee, Seung Yup
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6819744/
https://www.ncbi.nlm.nih.gov/pubmed/31687329
http://dx.doi.org/10.1016/j.eats.2019.05.007
_version_ 1783463805788880896
author Kim, Dong Ryul
Noh, Young-Min
Lee, Seung Yup
author_facet Kim, Dong Ryul
Noh, Young-Min
Lee, Seung Yup
author_sort Kim, Dong Ryul
collection PubMed
description Arthroscopic fixation of a greater tuberosity (GT) avulsion fracture by suture bridge repair has been described in several articles. However, all of them have used arthroscopic fixation of a small sized GT fracture fragment or have not used purely arthroscopic techniques. In this Technical Note, the authors describe another technique for large displaced GT fracture fixation by arthroscopy only, without any metal fixation. Standard anterior, posterior, lateral, and posterolateral viewing portals are established with an accessory portal for suture anchor insertion. During intra-articular examination, an anteroinferior capsulolabral tear, upper one-third subscapularis tendon tear, and posterosuperior displaced bony fragment are detected. A subscapularis tendon was repaired by a single-row technique. After repair, medial row anchors are inserted into the bare area of infraspinatus tendon and the posterior edge of supraspinatus tendon. A 1-PDS suture is used to pass strands of fiberwire. As with the remplissage procedure, the fiberwire was passed with an 18-gauge needle. Following the acromioplasty, the medial row tightening was done by reducing the fracture fragment. After that, the lateral row anchor was inserted into the bicipital groove, completing the suture bridge technique. This technique can effectively treat other pathologies, has less radiation hazard, and results in fewer soft tissue injuries.
format Online
Article
Text
id pubmed-6819744
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-68197442019-11-04 Arthroscopic Reduction and Suture Bridge Fixation of a Large Displaced Greater Tuberosity Fracture of the Humerus Kim, Dong Ryul Noh, Young-Min Lee, Seung Yup Arthrosc Tech Technical Note Arthroscopic fixation of a greater tuberosity (GT) avulsion fracture by suture bridge repair has been described in several articles. However, all of them have used arthroscopic fixation of a small sized GT fracture fragment or have not used purely arthroscopic techniques. In this Technical Note, the authors describe another technique for large displaced GT fracture fixation by arthroscopy only, without any metal fixation. Standard anterior, posterior, lateral, and posterolateral viewing portals are established with an accessory portal for suture anchor insertion. During intra-articular examination, an anteroinferior capsulolabral tear, upper one-third subscapularis tendon tear, and posterosuperior displaced bony fragment are detected. A subscapularis tendon was repaired by a single-row technique. After repair, medial row anchors are inserted into the bare area of infraspinatus tendon and the posterior edge of supraspinatus tendon. A 1-PDS suture is used to pass strands of fiberwire. As with the remplissage procedure, the fiberwire was passed with an 18-gauge needle. Following the acromioplasty, the medial row tightening was done by reducing the fracture fragment. After that, the lateral row anchor was inserted into the bicipital groove, completing the suture bridge technique. This technique can effectively treat other pathologies, has less radiation hazard, and results in fewer soft tissue injuries. Elsevier 2019-09-12 /pmc/articles/PMC6819744/ /pubmed/31687329 http://dx.doi.org/10.1016/j.eats.2019.05.007 Text en © 2019 by the Arthroscopy Association of North America. Published by Elsevier. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Technical Note
Kim, Dong Ryul
Noh, Young-Min
Lee, Seung Yup
Arthroscopic Reduction and Suture Bridge Fixation of a Large Displaced Greater Tuberosity Fracture of the Humerus
title Arthroscopic Reduction and Suture Bridge Fixation of a Large Displaced Greater Tuberosity Fracture of the Humerus
title_full Arthroscopic Reduction and Suture Bridge Fixation of a Large Displaced Greater Tuberosity Fracture of the Humerus
title_fullStr Arthroscopic Reduction and Suture Bridge Fixation of a Large Displaced Greater Tuberosity Fracture of the Humerus
title_full_unstemmed Arthroscopic Reduction and Suture Bridge Fixation of a Large Displaced Greater Tuberosity Fracture of the Humerus
title_short Arthroscopic Reduction and Suture Bridge Fixation of a Large Displaced Greater Tuberosity Fracture of the Humerus
title_sort arthroscopic reduction and suture bridge fixation of a large displaced greater tuberosity fracture of the humerus
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6819744/
https://www.ncbi.nlm.nih.gov/pubmed/31687329
http://dx.doi.org/10.1016/j.eats.2019.05.007
work_keys_str_mv AT kimdongryul arthroscopicreductionandsuturebridgefixationofalargedisplacedgreatertuberosityfractureofthehumerus
AT nohyoungmin arthroscopicreductionandsuturebridgefixationofalargedisplacedgreatertuberosityfractureofthehumerus
AT leeseungyup arthroscopicreductionandsuturebridgefixationofalargedisplacedgreatertuberosityfractureofthehumerus