Cargando…

An auxiliary factor for increasing the retention of short abutments

BACKGROUND: Retention is an essential factor in the sustainability of the prosthesis, especially for short abutment. Despite, the availability of several auxiliary applications, achieving a clinically good retention for cast crowns in prepared short teeth remains a major challenge for the practicing...

Descripción completa

Detalles Bibliográficos
Autores principales: AlShaarani, Fendi, Alaisami, Rami M., Aljerf, Loai, Jamous, Issam A., Elias, Kanaan, Jaber, Anas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6820267/
https://www.ncbi.nlm.nih.gov/pubmed/31687510
http://dx.doi.org/10.1016/j.heliyon.2019.e02674
_version_ 1783463901609852928
author AlShaarani, Fendi
Alaisami, Rami M.
Aljerf, Loai
Jamous, Issam A.
Elias, Kanaan
Jaber, Anas
author_facet AlShaarani, Fendi
Alaisami, Rami M.
Aljerf, Loai
Jamous, Issam A.
Elias, Kanaan
Jaber, Anas
author_sort AlShaarani, Fendi
collection PubMed
description BACKGROUND: Retention is an essential factor in the sustainability of the prosthesis, especially for short abutment. Despite, the availability of several auxiliary applications, achieving a clinically good retention for cast crowns in prepared short teeth remains a major challenge for the practicing dentist. OBJECTIVES: This study tests a new method for applying frustum-shaped grooves on short prepared abutments and compares them with traditional setting grooves. METHODS: Forty-eight copper machine-milled short dies with 3.5 mm length and 12(o) conversion with a chamfer finish line of 0.7 mm were prepared to mimic short prepared molars and distributed into 4 groups. A control group with two opposing setting grooves and two groups with dual opposing frustums, one of which was prepared to receive two integrated metal protrusions inside the casting that fit the frustums. Frustums were prepared with Komet bur No. 807 with dimensions 0.9 mm at the base and 0.7 mm at the occlusal surface. A direct wax-up was carried out on all dies and all castings were cemented with zinc phosphate cement. A pull-off test was applied until separation. Data were analysed to compare the correlation of the four groups using one-way ANOVA and Bonferroni test (p ≤ 0.05). RESULTS: The mean retentive values in Newton were as follows: the control group, 457.80; the setting grooves group, 461.07; the frustum group, 597.59; and the frustum group with the two metal protrusions, 919.80. The retention was increased by 65% in frustum group and doubled in frustum group with the metal protrusions. CONCLUSIONS: The results showed a statistical significance in retention in the frustum groups with and without metal protrusion over the retention of the control and the setting grooves groups.
format Online
Article
Text
id pubmed-6820267
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-68202672019-11-04 An auxiliary factor for increasing the retention of short abutments AlShaarani, Fendi Alaisami, Rami M. Aljerf, Loai Jamous, Issam A. Elias, Kanaan Jaber, Anas Heliyon Article BACKGROUND: Retention is an essential factor in the sustainability of the prosthesis, especially for short abutment. Despite, the availability of several auxiliary applications, achieving a clinically good retention for cast crowns in prepared short teeth remains a major challenge for the practicing dentist. OBJECTIVES: This study tests a new method for applying frustum-shaped grooves on short prepared abutments and compares them with traditional setting grooves. METHODS: Forty-eight copper machine-milled short dies with 3.5 mm length and 12(o) conversion with a chamfer finish line of 0.7 mm were prepared to mimic short prepared molars and distributed into 4 groups. A control group with two opposing setting grooves and two groups with dual opposing frustums, one of which was prepared to receive two integrated metal protrusions inside the casting that fit the frustums. Frustums were prepared with Komet bur No. 807 with dimensions 0.9 mm at the base and 0.7 mm at the occlusal surface. A direct wax-up was carried out on all dies and all castings were cemented with zinc phosphate cement. A pull-off test was applied until separation. Data were analysed to compare the correlation of the four groups using one-way ANOVA and Bonferroni test (p ≤ 0.05). RESULTS: The mean retentive values in Newton were as follows: the control group, 457.80; the setting grooves group, 461.07; the frustum group, 597.59; and the frustum group with the two metal protrusions, 919.80. The retention was increased by 65% in frustum group and doubled in frustum group with the metal protrusions. CONCLUSIONS: The results showed a statistical significance in retention in the frustum groups with and without metal protrusion over the retention of the control and the setting grooves groups. Elsevier 2019-10-21 /pmc/articles/PMC6820267/ /pubmed/31687510 http://dx.doi.org/10.1016/j.heliyon.2019.e02674 Text en © 2019 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
AlShaarani, Fendi
Alaisami, Rami M.
Aljerf, Loai
Jamous, Issam A.
Elias, Kanaan
Jaber, Anas
An auxiliary factor for increasing the retention of short abutments
title An auxiliary factor for increasing the retention of short abutments
title_full An auxiliary factor for increasing the retention of short abutments
title_fullStr An auxiliary factor for increasing the retention of short abutments
title_full_unstemmed An auxiliary factor for increasing the retention of short abutments
title_short An auxiliary factor for increasing the retention of short abutments
title_sort auxiliary factor for increasing the retention of short abutments
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6820267/
https://www.ncbi.nlm.nih.gov/pubmed/31687510
http://dx.doi.org/10.1016/j.heliyon.2019.e02674
work_keys_str_mv AT alshaaranifendi anauxiliaryfactorforincreasingtheretentionofshortabutments
AT alaisamiramim anauxiliaryfactorforincreasingtheretentionofshortabutments
AT aljerfloai anauxiliaryfactorforincreasingtheretentionofshortabutments
AT jamousissama anauxiliaryfactorforincreasingtheretentionofshortabutments
AT eliaskanaan anauxiliaryfactorforincreasingtheretentionofshortabutments
AT jaberanas anauxiliaryfactorforincreasingtheretentionofshortabutments
AT alshaaranifendi auxiliaryfactorforincreasingtheretentionofshortabutments
AT alaisamiramim auxiliaryfactorforincreasingtheretentionofshortabutments
AT aljerfloai auxiliaryfactorforincreasingtheretentionofshortabutments
AT jamousissama auxiliaryfactorforincreasingtheretentionofshortabutments
AT eliaskanaan auxiliaryfactorforincreasingtheretentionofshortabutments
AT jaberanas auxiliaryfactorforincreasingtheretentionofshortabutments