Cargando…

Estimating intrafraction tumor motion during fiducial-based liver stereotactic radiotherapy via an iterative closest point (ICP) algorithm

BACKGROUND: Tumor motion may compromise the accuracy of liver stereotactic radiotherapy. In order to carry out a precise planning, estimating liver tumor motion during radiotherapy has received a lot of attention. Previous approach may have difficult to deal with image data corrupted by noise. The i...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Wu-zhou, Liang, Zhi-wen, Cao, Yi, Cao, Ting-ting, Quan, Hong, Yang, Zhi-yong, Li, Qin, Dai, Zhi-tao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6820939/
https://www.ncbi.nlm.nih.gov/pubmed/31665054
http://dx.doi.org/10.1186/s13014-019-1401-2
_version_ 1783464049167564800
author Li, Wu-zhou
Liang, Zhi-wen
Cao, Yi
Cao, Ting-ting
Quan, Hong
Yang, Zhi-yong
Li, Qin
Dai, Zhi-tao
author_facet Li, Wu-zhou
Liang, Zhi-wen
Cao, Yi
Cao, Ting-ting
Quan, Hong
Yang, Zhi-yong
Li, Qin
Dai, Zhi-tao
author_sort Li, Wu-zhou
collection PubMed
description BACKGROUND: Tumor motion may compromise the accuracy of liver stereotactic radiotherapy. In order to carry out a precise planning, estimating liver tumor motion during radiotherapy has received a lot of attention. Previous approach may have difficult to deal with image data corrupted by noise. The iterative closest point (ICP) algorithm is widely used for estimating the rigid registration of three-dimensional point sets when these data were dense or corrupted. In the light of this, our study estimated the three-dimensional (3D) rigid motion of liver tumors during stereotactic liver radiotherapy using reconstructed 3D coordinates of fiducials based on the ICP algorithm. METHODS: Four hundred ninety-five pairs of orthogonal kilovoltage (KV) images from the CyberKnife stereo imaging system for 12 patients were used in this study. For each pair of images, the 3D coordinates of fiducial markers inside the liver were calculated via geometric derivations. The 3D coordinates were used to calculate the real-time translational and rotational motion of liver tumors around three axes via an ICP algorithm. The residual error was also investigated both with and without rotational correction. RESULTS: The translational shifts of liver tumors in left-right (LR), anterior-posterior (AP),and superior-inferior (SI) directions were 2.92 ± 1.98 mm, 5.54 ± 3.12 mm, and 16.22 ± 5.86 mm, respectively; the rotational angles in left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions were 3.95° ± 3.08°, 4.93° ± 2.90°, and 4.09° ± 1.99°, respectively. Rotational correction decreased 3D fiducial displacement from 1.19 ± 0.35 mm to 0.65 ± 0.24 mm (P<0.001). CONCLUSIONS: The maximum translational movement occurred in the SI direction. Rotational correction decreased fiducial displacements and increased tumor tracking accuracy.
format Online
Article
Text
id pubmed-6820939
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-68209392019-11-04 Estimating intrafraction tumor motion during fiducial-based liver stereotactic radiotherapy via an iterative closest point (ICP) algorithm Li, Wu-zhou Liang, Zhi-wen Cao, Yi Cao, Ting-ting Quan, Hong Yang, Zhi-yong Li, Qin Dai, Zhi-tao Radiat Oncol Research BACKGROUND: Tumor motion may compromise the accuracy of liver stereotactic radiotherapy. In order to carry out a precise planning, estimating liver tumor motion during radiotherapy has received a lot of attention. Previous approach may have difficult to deal with image data corrupted by noise. The iterative closest point (ICP) algorithm is widely used for estimating the rigid registration of three-dimensional point sets when these data were dense or corrupted. In the light of this, our study estimated the three-dimensional (3D) rigid motion of liver tumors during stereotactic liver radiotherapy using reconstructed 3D coordinates of fiducials based on the ICP algorithm. METHODS: Four hundred ninety-five pairs of orthogonal kilovoltage (KV) images from the CyberKnife stereo imaging system for 12 patients were used in this study. For each pair of images, the 3D coordinates of fiducial markers inside the liver were calculated via geometric derivations. The 3D coordinates were used to calculate the real-time translational and rotational motion of liver tumors around three axes via an ICP algorithm. The residual error was also investigated both with and without rotational correction. RESULTS: The translational shifts of liver tumors in left-right (LR), anterior-posterior (AP),and superior-inferior (SI) directions were 2.92 ± 1.98 mm, 5.54 ± 3.12 mm, and 16.22 ± 5.86 mm, respectively; the rotational angles in left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions were 3.95° ± 3.08°, 4.93° ± 2.90°, and 4.09° ± 1.99°, respectively. Rotational correction decreased 3D fiducial displacement from 1.19 ± 0.35 mm to 0.65 ± 0.24 mm (P<0.001). CONCLUSIONS: The maximum translational movement occurred in the SI direction. Rotational correction decreased fiducial displacements and increased tumor tracking accuracy. BioMed Central 2019-10-29 /pmc/articles/PMC6820939/ /pubmed/31665054 http://dx.doi.org/10.1186/s13014-019-1401-2 Text en © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Li, Wu-zhou
Liang, Zhi-wen
Cao, Yi
Cao, Ting-ting
Quan, Hong
Yang, Zhi-yong
Li, Qin
Dai, Zhi-tao
Estimating intrafraction tumor motion during fiducial-based liver stereotactic radiotherapy via an iterative closest point (ICP) algorithm
title Estimating intrafraction tumor motion during fiducial-based liver stereotactic radiotherapy via an iterative closest point (ICP) algorithm
title_full Estimating intrafraction tumor motion during fiducial-based liver stereotactic radiotherapy via an iterative closest point (ICP) algorithm
title_fullStr Estimating intrafraction tumor motion during fiducial-based liver stereotactic radiotherapy via an iterative closest point (ICP) algorithm
title_full_unstemmed Estimating intrafraction tumor motion during fiducial-based liver stereotactic radiotherapy via an iterative closest point (ICP) algorithm
title_short Estimating intrafraction tumor motion during fiducial-based liver stereotactic radiotherapy via an iterative closest point (ICP) algorithm
title_sort estimating intrafraction tumor motion during fiducial-based liver stereotactic radiotherapy via an iterative closest point (icp) algorithm
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6820939/
https://www.ncbi.nlm.nih.gov/pubmed/31665054
http://dx.doi.org/10.1186/s13014-019-1401-2
work_keys_str_mv AT liwuzhou estimatingintrafractiontumormotionduringfiducialbasedliverstereotacticradiotherapyviaaniterativeclosestpointicpalgorithm
AT liangzhiwen estimatingintrafractiontumormotionduringfiducialbasedliverstereotacticradiotherapyviaaniterativeclosestpointicpalgorithm
AT caoyi estimatingintrafractiontumormotionduringfiducialbasedliverstereotacticradiotherapyviaaniterativeclosestpointicpalgorithm
AT caotingting estimatingintrafractiontumormotionduringfiducialbasedliverstereotacticradiotherapyviaaniterativeclosestpointicpalgorithm
AT quanhong estimatingintrafractiontumormotionduringfiducialbasedliverstereotacticradiotherapyviaaniterativeclosestpointicpalgorithm
AT yangzhiyong estimatingintrafractiontumormotionduringfiducialbasedliverstereotacticradiotherapyviaaniterativeclosestpointicpalgorithm
AT liqin estimatingintrafractiontumormotionduringfiducialbasedliverstereotacticradiotherapyviaaniterativeclosestpointicpalgorithm
AT daizhitao estimatingintrafractiontumormotionduringfiducialbasedliverstereotacticradiotherapyviaaniterativeclosestpointicpalgorithm