Cargando…

Super-condenser enables labelfree nanoscopy

Labelfree nanoscopy encompasses optical imaging with a resolution in the 100-nm range using visible wavelengths. Here, we present a labelfree nanoscopy method that combines coherent imaging techniques with waveguide microscopy to realize a super-condenser featuring maximally inclined coherent darkfi...

Descripción completa

Detalles Bibliográficos
Autores principales: Ströhl, Florian, Opstad, Ida S., Tinguely, Jean-Claude, Dullo, Firehun T., Mela, Ioanna, Osterrieth, Johannes W. M., Ahluwalia, Balpreet S., Kaminski, Clemens F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Optical Society of America 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6825610/
https://www.ncbi.nlm.nih.gov/pubmed/31510402
http://dx.doi.org/10.1364/OE.27.025280
_version_ 1783464918318579712
author Ströhl, Florian
Opstad, Ida S.
Tinguely, Jean-Claude
Dullo, Firehun T.
Mela, Ioanna
Osterrieth, Johannes W. M.
Ahluwalia, Balpreet S.
Kaminski, Clemens F.
author_facet Ströhl, Florian
Opstad, Ida S.
Tinguely, Jean-Claude
Dullo, Firehun T.
Mela, Ioanna
Osterrieth, Johannes W. M.
Ahluwalia, Balpreet S.
Kaminski, Clemens F.
author_sort Ströhl, Florian
collection PubMed
description Labelfree nanoscopy encompasses optical imaging with a resolution in the 100-nm range using visible wavelengths. Here, we present a labelfree nanoscopy method that combines coherent imaging techniques with waveguide microscopy to realize a super-condenser featuring maximally inclined coherent darkfield illumination with artificially stretched wave vectors due to large refractive indices of the employed Si(3)N(4) waveguide material. We produce the required coherent plane wave illumination for Fourier ptychography over imaging areas 400 μm(2) in size via adiabatically tapered single-mode waveguides and tackle the overlap constraints of the Fourier ptychography phase retrieval algorithm two-fold: first, the directionality of the illumination wave vector is changed sequentially via a multiplexed input structure of the waveguide chip layout, and second, the wave vector modulus is shortend via step-wise increases of the illumination light wavelength over the visible spectrum. We test the method in simulations and in experiments and provide details on the underlying image formation theory as well as the reconstruction algorithm. While the generated Fourier ptychography reconstructions are found to be prone to image artefacts, an alternative coherent imaging method, rotating coherent scattering microscopy (ROCS), is found to be more robust against artefacts but with less achievable resolution.
format Online
Article
Text
id pubmed-6825610
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-68256102020-08-22 Super-condenser enables labelfree nanoscopy Ströhl, Florian Opstad, Ida S. Tinguely, Jean-Claude Dullo, Firehun T. Mela, Ioanna Osterrieth, Johannes W. M. Ahluwalia, Balpreet S. Kaminski, Clemens F. Opt Express Article Labelfree nanoscopy encompasses optical imaging with a resolution in the 100-nm range using visible wavelengths. Here, we present a labelfree nanoscopy method that combines coherent imaging techniques with waveguide microscopy to realize a super-condenser featuring maximally inclined coherent darkfield illumination with artificially stretched wave vectors due to large refractive indices of the employed Si(3)N(4) waveguide material. We produce the required coherent plane wave illumination for Fourier ptychography over imaging areas 400 μm(2) in size via adiabatically tapered single-mode waveguides and tackle the overlap constraints of the Fourier ptychography phase retrieval algorithm two-fold: first, the directionality of the illumination wave vector is changed sequentially via a multiplexed input structure of the waveguide chip layout, and second, the wave vector modulus is shortend via step-wise increases of the illumination light wavelength over the visible spectrum. We test the method in simulations and in experiments and provide details on the underlying image formation theory as well as the reconstruction algorithm. While the generated Fourier ptychography reconstructions are found to be prone to image artefacts, an alternative coherent imaging method, rotating coherent scattering microscopy (ROCS), is found to be more robust against artefacts but with less achievable resolution. Optical Society of America 2019-08-22 /pmc/articles/PMC6825610/ /pubmed/31510402 http://dx.doi.org/10.1364/OE.27.025280 Text en Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI. Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License (http://creativecommons.org/licenses/by/4.0/) . Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI.
spellingShingle Article
Ströhl, Florian
Opstad, Ida S.
Tinguely, Jean-Claude
Dullo, Firehun T.
Mela, Ioanna
Osterrieth, Johannes W. M.
Ahluwalia, Balpreet S.
Kaminski, Clemens F.
Super-condenser enables labelfree nanoscopy
title Super-condenser enables labelfree nanoscopy
title_full Super-condenser enables labelfree nanoscopy
title_fullStr Super-condenser enables labelfree nanoscopy
title_full_unstemmed Super-condenser enables labelfree nanoscopy
title_short Super-condenser enables labelfree nanoscopy
title_sort super-condenser enables labelfree nanoscopy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6825610/
https://www.ncbi.nlm.nih.gov/pubmed/31510402
http://dx.doi.org/10.1364/OE.27.025280
work_keys_str_mv AT strohlflorian supercondenserenableslabelfreenanoscopy
AT opstadidas supercondenserenableslabelfreenanoscopy
AT tinguelyjeanclaude supercondenserenableslabelfreenanoscopy
AT dullofirehunt supercondenserenableslabelfreenanoscopy
AT melaioanna supercondenserenableslabelfreenanoscopy
AT osterriethjohanneswm supercondenserenableslabelfreenanoscopy
AT ahluwaliabalpreets supercondenserenableslabelfreenanoscopy
AT kaminskiclemensf supercondenserenableslabelfreenanoscopy