Anchoring lumen-apposing metal stent with coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: any benefit?

BACKGROUND: Anchoring double-pigtail plastic stents (DPSs) within lumen-apposing metal stents (LAMSs) has been proposed to prevent adverse events during endoscopic drainage of pancreatic fluid collections (PFCs). We sought to compare the outcomes of patients who received LAMSs alone and those who re...

Descripción completa

Detalles Bibliográficos
Autores principales: Ali, Saad Emhmed, Benrajab, Karim, Mardini, Houssam, Su, Leon, Gabr, Moamen, Frandah, Wesam M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hellenic Society of Gastroenterology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6826067/
https://www.ncbi.nlm.nih.gov/pubmed/31700240
http://dx.doi.org/10.20524/aog.2019.0414
_version_ 1783465005327319040
author Ali, Saad Emhmed
Benrajab, Karim
Mardini, Houssam
Su, Leon
Gabr, Moamen
Frandah, Wesam M.
author_facet Ali, Saad Emhmed
Benrajab, Karim
Mardini, Houssam
Su, Leon
Gabr, Moamen
Frandah, Wesam M.
author_sort Ali, Saad Emhmed
collection PubMed
description BACKGROUND: Anchoring double-pigtail plastic stents (DPSs) within lumen-apposing metal stents (LAMSs) has been proposed to prevent adverse events during endoscopic drainage of pancreatic fluid collections (PFCs). We sought to compare the outcomes of patients who received LAMSs alone and those who received both LAMSs and anchoring DPSs for drainage of PFCs. METHODS: A retrospective study was conducted at the University of Kentucky. Patients with PFCs who underwent endoscopic ultrasound-guided drainage using LAMSs, with or without DPSs, between January 2016 and March 2018 were included. Categorical data were analyzed using chi-square tests, and continuous variables using 2-sample t-tests. Adverse events were defined according to the American Society for Gastrointestinal Endoscopy’s Lexicon. The primary outcome was to evaluate the efficacy (PFC resolution), and safety (adverse events) of LAMSs with or without DPSs used to drain PFCs. RESULTS: Fifty-seven patients with PFCs were treated by 2 experienced endoscopists over 26 months. Twenty-one (37%) patients received LAMSs alone, and 36 (63%) received LAMSs plus DPSs. Forty-three patients had walled-off pancreatic necrosis, and 14 patients had pancreatic pseudocyst. Clinical success (resolution of PFCs) was achieved in 15 patients (71.4%) in the LAMSs alone group, and 21 patients (58.3%) with LAMSs plus DPSs (P=0.32). In patients with LAMSs alone, 6 patients (28.6%) had adverse events, while in those with LAMSs plus DPSs, 14 (38.9%) patients had adverse events (P=0.43). CONCLUSION: No significant difference was identified in fluid resolution or adverse events between patients with LAMSs alone and those with LAMSs plus DPSs.
format Online
Article
Text
id pubmed-6826067
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hellenic Society of Gastroenterology
record_format MEDLINE/PubMed
spelling pubmed-68260672019-11-07 Anchoring lumen-apposing metal stent with coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: any benefit? Ali, Saad Emhmed Benrajab, Karim Mardini, Houssam Su, Leon Gabr, Moamen Frandah, Wesam M. Ann Gastroenterol Original Article BACKGROUND: Anchoring double-pigtail plastic stents (DPSs) within lumen-apposing metal stents (LAMSs) has been proposed to prevent adverse events during endoscopic drainage of pancreatic fluid collections (PFCs). We sought to compare the outcomes of patients who received LAMSs alone and those who received both LAMSs and anchoring DPSs for drainage of PFCs. METHODS: A retrospective study was conducted at the University of Kentucky. Patients with PFCs who underwent endoscopic ultrasound-guided drainage using LAMSs, with or without DPSs, between January 2016 and March 2018 were included. Categorical data were analyzed using chi-square tests, and continuous variables using 2-sample t-tests. Adverse events were defined according to the American Society for Gastrointestinal Endoscopy’s Lexicon. The primary outcome was to evaluate the efficacy (PFC resolution), and safety (adverse events) of LAMSs with or without DPSs used to drain PFCs. RESULTS: Fifty-seven patients with PFCs were treated by 2 experienced endoscopists over 26 months. Twenty-one (37%) patients received LAMSs alone, and 36 (63%) received LAMSs plus DPSs. Forty-three patients had walled-off pancreatic necrosis, and 14 patients had pancreatic pseudocyst. Clinical success (resolution of PFCs) was achieved in 15 patients (71.4%) in the LAMSs alone group, and 21 patients (58.3%) with LAMSs plus DPSs (P=0.32). In patients with LAMSs alone, 6 patients (28.6%) had adverse events, while in those with LAMSs plus DPSs, 14 (38.9%) patients had adverse events (P=0.43). CONCLUSION: No significant difference was identified in fluid resolution or adverse events between patients with LAMSs alone and those with LAMSs plus DPSs. Hellenic Society of Gastroenterology 2019 2019-09-23 /pmc/articles/PMC6826067/ /pubmed/31700240 http://dx.doi.org/10.20524/aog.2019.0414 Text en Copyright: © Hellenic Society of Gastroenterology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Ali, Saad Emhmed
Benrajab, Karim
Mardini, Houssam
Su, Leon
Gabr, Moamen
Frandah, Wesam M.
Anchoring lumen-apposing metal stent with coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: any benefit?
title Anchoring lumen-apposing metal stent with coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: any benefit?
title_full Anchoring lumen-apposing metal stent with coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: any benefit?
title_fullStr Anchoring lumen-apposing metal stent with coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: any benefit?
title_full_unstemmed Anchoring lumen-apposing metal stent with coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: any benefit?
title_short Anchoring lumen-apposing metal stent with coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: any benefit?
title_sort anchoring lumen-apposing metal stent with coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: any benefit?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6826067/
https://www.ncbi.nlm.nih.gov/pubmed/31700240
http://dx.doi.org/10.20524/aog.2019.0414
work_keys_str_mv AT alisaademhmed anchoringlumenapposingmetalstentwithcoaxialplasticstentforendoscopicultrasoundguideddrainageofpancreaticfluidcollectionsanybenefit
AT benrajabkarim anchoringlumenapposingmetalstentwithcoaxialplasticstentforendoscopicultrasoundguideddrainageofpancreaticfluidcollectionsanybenefit
AT mardinihoussam anchoringlumenapposingmetalstentwithcoaxialplasticstentforendoscopicultrasoundguideddrainageofpancreaticfluidcollectionsanybenefit
AT suleon anchoringlumenapposingmetalstentwithcoaxialplasticstentforendoscopicultrasoundguideddrainageofpancreaticfluidcollectionsanybenefit
AT gabrmoamen anchoringlumenapposingmetalstentwithcoaxialplasticstentforendoscopicultrasoundguideddrainageofpancreaticfluidcollectionsanybenefit
AT frandahwesamm anchoringlumenapposingmetalstentwithcoaxialplasticstentforendoscopicultrasoundguideddrainageofpancreaticfluidcollectionsanybenefit