Cargando…

Contact lens fitting after corneal collagen cross-linking

BACKGROUND: Contact lenses (CLs) remain the mainstay in improving vision in patients having keratoconus. With corneal collagen cross-linking (CXL) performed worldwide, whether the same CLs can be used or needs replacement needed to be assessed and considered. AIMS: The aim of this study was to evalu...

Descripción completa

Detalles Bibliográficos
Autores principales: Mandathara, Preeji Suderman, Kalaiselvan, Parthasarathi, Rathi, Varsha M., Murthy, Somasheila I., Taneja, Mukesh, Sangwan, Virender S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6826600/
https://www.ncbi.nlm.nih.gov/pubmed/31902993
http://dx.doi.org/10.4103/ojo.OJO_43_2018
_version_ 1783465126547947520
author Mandathara, Preeji Suderman
Kalaiselvan, Parthasarathi
Rathi, Varsha M.
Murthy, Somasheila I.
Taneja, Mukesh
Sangwan, Virender S.
author_facet Mandathara, Preeji Suderman
Kalaiselvan, Parthasarathi
Rathi, Varsha M.
Murthy, Somasheila I.
Taneja, Mukesh
Sangwan, Virender S.
author_sort Mandathara, Preeji Suderman
collection PubMed
description BACKGROUND: Contact lenses (CLs) remain the mainstay in improving vision in patients having keratoconus. With corneal collagen cross-linking (CXL) performed worldwide, whether the same CLs can be used or needs replacement needed to be assessed and considered. AIMS: The aim of this study was to evaluate the changes in CL fitting following CXL. SETTINGS AND DESIGN: This is a retrospective study conducted at a tertiary center. SUBJECTS AND METHODS: We analyzed the medical records of patients who underwent CXL and used CL. Data collected included demographics, pre- and post-CXL refraction, corneal topography, anterior-segment examination, and CL [rigid gas permeable(RGP)] fitting details and duration between CXL and RGP fitting. STATISTICAL ANALYSIS: Descriptive analysis and paired t-test were used to compare the pre- and post-CXL data on refraction, visual acuity, and CL parameters. The statistical significance was kept at P < 0.05. RESULTS: Thirty-four eyes (keratoconus = 32, pellucid marginal degeneration = 1, and post-LASIK ectasia = 1) of 27 patients who used CL before and after undergoing CXL were analyzed. Mean duration between CXL and RGP lens use was 2.53 months. Mean sphere and cylinder post-CXL was −4.11 ± 4.32 D and −3.54 ± 2.51 D, respectively. A mean change of 0.75 ± 3.72 D sphere and 0.71 ± 3.39 D cylinder was noted post-CXL. The post-CXL best spectacle-corrected visual acuity (CVA) was 0.52 ± 0.36 and with RGP lens it was 0.09 ± 0.18. There was no significant difference in pre- and post-CXL RGP lens CVA (0.07 ± 0.09 and 0.09 ± 0.18, respectively; P = 0.556). Pre-CXL, 3-point-touch fitting was in 24 eyes (70.59%) and central fluorescein pooling was in 10 eyes (29.41%). Post-CXL, 30 eyes (88.24%) had 3-point-touch and central fluorescein pooling was found in four eyes (11.76%). One patient had CL intolerance after CXL. Of the 32 keratoconus eyes, 62.5% (n = 20 eyes) were prescribed new lenses; 37.5% (n = 12 eyes) continued using own lenses. CONCLUSIONS: There was no significant difference in refraction, topography indices, and RGP lens parameters pre- and post-CXL. However, changes in RGP lens fitting characteristics suggest a possible change in shape or apex location of the cornea after CXL. RGP lenses remain the best option to improve visual acuity after CXL in corneal ectasia.
format Online
Article
Text
id pubmed-6826600
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-68266002020-01-03 Contact lens fitting after corneal collagen cross-linking Mandathara, Preeji Suderman Kalaiselvan, Parthasarathi Rathi, Varsha M. Murthy, Somasheila I. Taneja, Mukesh Sangwan, Virender S. Oman J Ophthalmol Original Article BACKGROUND: Contact lenses (CLs) remain the mainstay in improving vision in patients having keratoconus. With corneal collagen cross-linking (CXL) performed worldwide, whether the same CLs can be used or needs replacement needed to be assessed and considered. AIMS: The aim of this study was to evaluate the changes in CL fitting following CXL. SETTINGS AND DESIGN: This is a retrospective study conducted at a tertiary center. SUBJECTS AND METHODS: We analyzed the medical records of patients who underwent CXL and used CL. Data collected included demographics, pre- and post-CXL refraction, corneal topography, anterior-segment examination, and CL [rigid gas permeable(RGP)] fitting details and duration between CXL and RGP fitting. STATISTICAL ANALYSIS: Descriptive analysis and paired t-test were used to compare the pre- and post-CXL data on refraction, visual acuity, and CL parameters. The statistical significance was kept at P < 0.05. RESULTS: Thirty-four eyes (keratoconus = 32, pellucid marginal degeneration = 1, and post-LASIK ectasia = 1) of 27 patients who used CL before and after undergoing CXL were analyzed. Mean duration between CXL and RGP lens use was 2.53 months. Mean sphere and cylinder post-CXL was −4.11 ± 4.32 D and −3.54 ± 2.51 D, respectively. A mean change of 0.75 ± 3.72 D sphere and 0.71 ± 3.39 D cylinder was noted post-CXL. The post-CXL best spectacle-corrected visual acuity (CVA) was 0.52 ± 0.36 and with RGP lens it was 0.09 ± 0.18. There was no significant difference in pre- and post-CXL RGP lens CVA (0.07 ± 0.09 and 0.09 ± 0.18, respectively; P = 0.556). Pre-CXL, 3-point-touch fitting was in 24 eyes (70.59%) and central fluorescein pooling was in 10 eyes (29.41%). Post-CXL, 30 eyes (88.24%) had 3-point-touch and central fluorescein pooling was found in four eyes (11.76%). One patient had CL intolerance after CXL. Of the 32 keratoconus eyes, 62.5% (n = 20 eyes) were prescribed new lenses; 37.5% (n = 12 eyes) continued using own lenses. CONCLUSIONS: There was no significant difference in refraction, topography indices, and RGP lens parameters pre- and post-CXL. However, changes in RGP lens fitting characteristics suggest a possible change in shape or apex location of the cornea after CXL. RGP lenses remain the best option to improve visual acuity after CXL in corneal ectasia. Wolters Kluwer - Medknow 2019-10-11 /pmc/articles/PMC6826600/ /pubmed/31902993 http://dx.doi.org/10.4103/ojo.OJO_43_2018 Text en Copyright: © 2019 Oman Ophthalmic Society http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Mandathara, Preeji Suderman
Kalaiselvan, Parthasarathi
Rathi, Varsha M.
Murthy, Somasheila I.
Taneja, Mukesh
Sangwan, Virender S.
Contact lens fitting after corneal collagen cross-linking
title Contact lens fitting after corneal collagen cross-linking
title_full Contact lens fitting after corneal collagen cross-linking
title_fullStr Contact lens fitting after corneal collagen cross-linking
title_full_unstemmed Contact lens fitting after corneal collagen cross-linking
title_short Contact lens fitting after corneal collagen cross-linking
title_sort contact lens fitting after corneal collagen cross-linking
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6826600/
https://www.ncbi.nlm.nih.gov/pubmed/31902993
http://dx.doi.org/10.4103/ojo.OJO_43_2018
work_keys_str_mv AT mandatharapreejisuderman contactlensfittingaftercornealcollagencrosslinking
AT kalaiselvanparthasarathi contactlensfittingaftercornealcollagencrosslinking
AT rathivarsham contactlensfittingaftercornealcollagencrosslinking
AT murthysomasheilai contactlensfittingaftercornealcollagencrosslinking
AT tanejamukesh contactlensfittingaftercornealcollagencrosslinking
AT sangwanvirenders contactlensfittingaftercornealcollagencrosslinking