Cargando…

Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks

OBJECTIVES: To evaluate the influence of baseline parameters on the occurrence of stent-graft surface movement after endovascular aneurysm repair (EVAR) and to investigate its association with migration and stent-graft-related endoleaks (srEL). METHODS: In this retrospective, cross-sectional study,...

Descripción completa

Detalles Bibliográficos
Autores principales: Asenbaum, Ulrika, Schoder, Maria, Schwartz, Ernst, Langs, Georg, Baltzer, Pascal, Wolf, Florian, Prusa, Alexander M., Loewe, Christian, Nolz, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6828830/
https://www.ncbi.nlm.nih.gov/pubmed/31250169
http://dx.doi.org/10.1007/s00330-019-06282-w
_version_ 1783465434923663360
author Asenbaum, Ulrika
Schoder, Maria
Schwartz, Ernst
Langs, Georg
Baltzer, Pascal
Wolf, Florian
Prusa, Alexander M.
Loewe, Christian
Nolz, Richard
author_facet Asenbaum, Ulrika
Schoder, Maria
Schwartz, Ernst
Langs, Georg
Baltzer, Pascal
Wolf, Florian
Prusa, Alexander M.
Loewe, Christian
Nolz, Richard
author_sort Asenbaum, Ulrika
collection PubMed
description OBJECTIVES: To evaluate the influence of baseline parameters on the occurrence of stent-graft surface movement after endovascular aneurysm repair (EVAR) and to investigate its association with migration and stent-graft-related endoleaks (srEL). METHODS: In this retrospective, cross-sectional study, three-dimensional surface models of the stent-graft, delimited by landmarks using custom-built software, were derived from the pre-discharge and last follow-up computed tomography angiography (CTA). Stent-graft surface movement in the proximal anchoring zone between these examinations was considered significant at a threshold of 9 mm. The Cox proportional hazards model was used to determine baseline variables associated with the occurrence of stent-graft surface movement. The association between migration and srEL with stent-graft surface movement was tested with the chi-square and the Fisher exact test, respectively. RESULTS: Stent-graft surface movement was observed in 54 (28.9%) of 187 patients. Multivariate analysis revealed that age ([HR] 1.05; p = 0.017), proximal neck diameter ([HR] 5.07; p < 0.001), infrarenal aortic neck angulation ([HR] 1.02, p = 0.002), and proximal neck length ([HR] 0.62, p < 0.001) were significantly associated with the occurrence of stent-graft surface movement. Migration and srEL occurred in 17 (31.5%) and 5 (9.3%) patients, with and 11 (8.3%) and 2 (1.5%) without stent-graft surface movement (p < 0.001, p = 0.022). CONCLUSIONS: Age, neck diameter, infrarenal neck angulation, and proximal neck length were significantly associated with the occurrence of stent-graft surface movement. Apart from possible use of adjunctive sealing systems, concerned patients may benefit from regular CTA surveillance, enabling timely diagnosis of subtle changes of stent-graft position. KEY POINTS: • Stent-graft surface movement, demonstrating subtle, three-dimensional changes in stent-graft position in the proximal anchoring zone, can be derived from CTA examinations. • Age, proximal neck diameter, and infrarenal neck angulation were significantly associated with an increased incidence of stent-graft surface movement. Stent-graft surface movement is significantly more frequent in patients with stent-graft migration and stent-graft-related endoleaks. • Consideration of risk factors for stent-graft surface movement may help to identify patients who might benefit from regular CTA surveillance and timely diagnosis of subtle changes of stent-graft position, enabling re-interventions to prevent migration and srEL. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00330-019-06282-w) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6828830
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-68288302019-11-18 Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks Asenbaum, Ulrika Schoder, Maria Schwartz, Ernst Langs, Georg Baltzer, Pascal Wolf, Florian Prusa, Alexander M. Loewe, Christian Nolz, Richard Eur Radiol Vascular-Interventional OBJECTIVES: To evaluate the influence of baseline parameters on the occurrence of stent-graft surface movement after endovascular aneurysm repair (EVAR) and to investigate its association with migration and stent-graft-related endoleaks (srEL). METHODS: In this retrospective, cross-sectional study, three-dimensional surface models of the stent-graft, delimited by landmarks using custom-built software, were derived from the pre-discharge and last follow-up computed tomography angiography (CTA). Stent-graft surface movement in the proximal anchoring zone between these examinations was considered significant at a threshold of 9 mm. The Cox proportional hazards model was used to determine baseline variables associated with the occurrence of stent-graft surface movement. The association between migration and srEL with stent-graft surface movement was tested with the chi-square and the Fisher exact test, respectively. RESULTS: Stent-graft surface movement was observed in 54 (28.9%) of 187 patients. Multivariate analysis revealed that age ([HR] 1.05; p = 0.017), proximal neck diameter ([HR] 5.07; p < 0.001), infrarenal aortic neck angulation ([HR] 1.02, p = 0.002), and proximal neck length ([HR] 0.62, p < 0.001) were significantly associated with the occurrence of stent-graft surface movement. Migration and srEL occurred in 17 (31.5%) and 5 (9.3%) patients, with and 11 (8.3%) and 2 (1.5%) without stent-graft surface movement (p < 0.001, p = 0.022). CONCLUSIONS: Age, neck diameter, infrarenal neck angulation, and proximal neck length were significantly associated with the occurrence of stent-graft surface movement. Apart from possible use of adjunctive sealing systems, concerned patients may benefit from regular CTA surveillance, enabling timely diagnosis of subtle changes of stent-graft position. KEY POINTS: • Stent-graft surface movement, demonstrating subtle, three-dimensional changes in stent-graft position in the proximal anchoring zone, can be derived from CTA examinations. • Age, proximal neck diameter, and infrarenal neck angulation were significantly associated with an increased incidence of stent-graft surface movement. Stent-graft surface movement is significantly more frequent in patients with stent-graft migration and stent-graft-related endoleaks. • Consideration of risk factors for stent-graft surface movement may help to identify patients who might benefit from regular CTA surveillance and timely diagnosis of subtle changes of stent-graft position, enabling re-interventions to prevent migration and srEL. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00330-019-06282-w) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2019-06-27 2019 /pmc/articles/PMC6828830/ /pubmed/31250169 http://dx.doi.org/10.1007/s00330-019-06282-w Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Vascular-Interventional
Asenbaum, Ulrika
Schoder, Maria
Schwartz, Ernst
Langs, Georg
Baltzer, Pascal
Wolf, Florian
Prusa, Alexander M.
Loewe, Christian
Nolz, Richard
Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks
title Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks
title_full Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks
title_fullStr Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks
title_full_unstemmed Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks
title_short Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks
title_sort stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks
topic Vascular-Interventional
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6828830/
https://www.ncbi.nlm.nih.gov/pubmed/31250169
http://dx.doi.org/10.1007/s00330-019-06282-w
work_keys_str_mv AT asenbaumulrika stentgraftsurfacemovementafterendovascularaneurysmrepairbaselineparametersforpredictionandassociationwithmigrationandstentgraftrelatedendoleaks
AT schodermaria stentgraftsurfacemovementafterendovascularaneurysmrepairbaselineparametersforpredictionandassociationwithmigrationandstentgraftrelatedendoleaks
AT schwartzernst stentgraftsurfacemovementafterendovascularaneurysmrepairbaselineparametersforpredictionandassociationwithmigrationandstentgraftrelatedendoleaks
AT langsgeorg stentgraftsurfacemovementafterendovascularaneurysmrepairbaselineparametersforpredictionandassociationwithmigrationandstentgraftrelatedendoleaks
AT baltzerpascal stentgraftsurfacemovementafterendovascularaneurysmrepairbaselineparametersforpredictionandassociationwithmigrationandstentgraftrelatedendoleaks
AT wolfflorian stentgraftsurfacemovementafterendovascularaneurysmrepairbaselineparametersforpredictionandassociationwithmigrationandstentgraftrelatedendoleaks
AT prusaalexanderm stentgraftsurfacemovementafterendovascularaneurysmrepairbaselineparametersforpredictionandassociationwithmigrationandstentgraftrelatedendoleaks
AT loewechristian stentgraftsurfacemovementafterendovascularaneurysmrepairbaselineparametersforpredictionandassociationwithmigrationandstentgraftrelatedendoleaks
AT nolzrichard stentgraftsurfacemovementafterendovascularaneurysmrepairbaselineparametersforpredictionandassociationwithmigrationandstentgraftrelatedendoleaks