Cargando…

Normal Values of the Mitral-Aortic Intervalvular Fibrosa Thickness: A Multimodality Study

BACKGROUND: The avascular region of the fibrous body between the mitral and aortic valves, named mitral-aortic intervalvular fibrosa (MAIVF), is often involved in the periaortic diffusion of infective endocarditis (IE), resulting in abscess or pseudoaneurysm formation. The early recognition of these...

Descripción completa

Detalles Bibliográficos
Autores principales: Cresti, Alberto, Baratta, Pasquale, De Sensi, Francesco, Solari, Marco, Sposato, Bruno, Minelli, Stefano, Cioffi, Nevada, Franci, Luca, Scalese, M., Limbruno, Ugo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6829758/
https://www.ncbi.nlm.nih.gov/pubmed/31728299
http://dx.doi.org/10.4103/jcecho.jcecho_28_19
_version_ 1783465632385204224
author Cresti, Alberto
Baratta, Pasquale
De Sensi, Francesco
Solari, Marco
Sposato, Bruno
Minelli, Stefano
Cioffi, Nevada
Franci, Luca
Scalese, M.
Limbruno, Ugo
author_facet Cresti, Alberto
Baratta, Pasquale
De Sensi, Francesco
Solari, Marco
Sposato, Bruno
Minelli, Stefano
Cioffi, Nevada
Franci, Luca
Scalese, M.
Limbruno, Ugo
author_sort Cresti, Alberto
collection PubMed
description BACKGROUND: The avascular region of the fibrous body between the mitral and aortic valves, named mitral-aortic intervalvular fibrosa (MAIVF), is often involved in the periaortic diffusion of infective endocarditis (IE), resulting in abscess or pseudoaneurysm formation. The early recognition of these life-threatening complications is of crucial importance, as urgent surgical correction is necessary. In the first stages of the abscess formation, the only sign is an increased thickness of the MAIVF. To the best of our knowledge, normal transesophageal echocardiography (TEE) examination reference values for MAIVF thickness has not yet been established. The aim of the study was to define the normal ranges of MAIVF thickness in a population of healthy adults who underwent a TEE examination. MATERIALS AND METHODS: A population of consecutive adult patients who underwent a TEE examination was enrolled in the study. Measurement was performed in short-axis (SAX) and long-axis (LAX) views. Mean-2 standard deviations (mean-2SDs) and 5%, 10%, 90%, and 95% confidence intervals were evaluated. A comparison with MAIVF thickness in patients affected by aortic IE complicated by abscess formation was performed, and receiver operating characteristic (ROC) curves were constructed to achieve the optimal cutoff value of normality. RESULTS: A total of 477 consecutive Caucasian adult patients were enrolled (mean age: 69 years, range: 27–93 years). Mean-2SD MAIVF measurement in SAX view was 0.325 cm (95% confidence interval [CI]: 0.319–0.330 cm) and in LAX view was 0.340 cm (95% CI: 0.334–0.346 cm). Computed tomography–MAIVF mean measurement (±2SD) was 0.237 cm (95% CI: 0.110–0.340 cm). ROC curves showed that a cutoff SAX value measurement of 0.552 (area under the curve [AUC]: 95.2%) had a sensibility of 88.2% and a specificity of 92.4%; a LAX measurement value of 0.623 (AUC: 93.3%) had a sensibility of 82.7% and a specificity of 85.7%. The multivariate analysis showed no significant correlation between MAIVF thickness, age, and sex. CONCLUSION: In healthy patients, MAIVF thickness should not exceed 0.600 cm. Above these values, the suspicion of a periaortic abscess formation should be raised. MAIVF increased thickness may be an early sign of perivalvular diffusion requiring an urgent endocarditis team evaluation.
format Online
Article
Text
id pubmed-6829758
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-68297582019-11-14 Normal Values of the Mitral-Aortic Intervalvular Fibrosa Thickness: A Multimodality Study Cresti, Alberto Baratta, Pasquale De Sensi, Francesco Solari, Marco Sposato, Bruno Minelli, Stefano Cioffi, Nevada Franci, Luca Scalese, M. Limbruno, Ugo J Cardiovasc Echogr Original Article BACKGROUND: The avascular region of the fibrous body between the mitral and aortic valves, named mitral-aortic intervalvular fibrosa (MAIVF), is often involved in the periaortic diffusion of infective endocarditis (IE), resulting in abscess or pseudoaneurysm formation. The early recognition of these life-threatening complications is of crucial importance, as urgent surgical correction is necessary. In the first stages of the abscess formation, the only sign is an increased thickness of the MAIVF. To the best of our knowledge, normal transesophageal echocardiography (TEE) examination reference values for MAIVF thickness has not yet been established. The aim of the study was to define the normal ranges of MAIVF thickness in a population of healthy adults who underwent a TEE examination. MATERIALS AND METHODS: A population of consecutive adult patients who underwent a TEE examination was enrolled in the study. Measurement was performed in short-axis (SAX) and long-axis (LAX) views. Mean-2 standard deviations (mean-2SDs) and 5%, 10%, 90%, and 95% confidence intervals were evaluated. A comparison with MAIVF thickness in patients affected by aortic IE complicated by abscess formation was performed, and receiver operating characteristic (ROC) curves were constructed to achieve the optimal cutoff value of normality. RESULTS: A total of 477 consecutive Caucasian adult patients were enrolled (mean age: 69 years, range: 27–93 years). Mean-2SD MAIVF measurement in SAX view was 0.325 cm (95% confidence interval [CI]: 0.319–0.330 cm) and in LAX view was 0.340 cm (95% CI: 0.334–0.346 cm). Computed tomography–MAIVF mean measurement (±2SD) was 0.237 cm (95% CI: 0.110–0.340 cm). ROC curves showed that a cutoff SAX value measurement of 0.552 (area under the curve [AUC]: 95.2%) had a sensibility of 88.2% and a specificity of 92.4%; a LAX measurement value of 0.623 (AUC: 93.3%) had a sensibility of 82.7% and a specificity of 85.7%. The multivariate analysis showed no significant correlation between MAIVF thickness, age, and sex. CONCLUSION: In healthy patients, MAIVF thickness should not exceed 0.600 cm. Above these values, the suspicion of a periaortic abscess formation should be raised. MAIVF increased thickness may be an early sign of perivalvular diffusion requiring an urgent endocarditis team evaluation. Wolters Kluwer - Medknow 2019 /pmc/articles/PMC6829758/ /pubmed/31728299 http://dx.doi.org/10.4103/jcecho.jcecho_28_19 Text en Copyright: © 2019 Journal of Cardiovascular Echography http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Cresti, Alberto
Baratta, Pasquale
De Sensi, Francesco
Solari, Marco
Sposato, Bruno
Minelli, Stefano
Cioffi, Nevada
Franci, Luca
Scalese, M.
Limbruno, Ugo
Normal Values of the Mitral-Aortic Intervalvular Fibrosa Thickness: A Multimodality Study
title Normal Values of the Mitral-Aortic Intervalvular Fibrosa Thickness: A Multimodality Study
title_full Normal Values of the Mitral-Aortic Intervalvular Fibrosa Thickness: A Multimodality Study
title_fullStr Normal Values of the Mitral-Aortic Intervalvular Fibrosa Thickness: A Multimodality Study
title_full_unstemmed Normal Values of the Mitral-Aortic Intervalvular Fibrosa Thickness: A Multimodality Study
title_short Normal Values of the Mitral-Aortic Intervalvular Fibrosa Thickness: A Multimodality Study
title_sort normal values of the mitral-aortic intervalvular fibrosa thickness: a multimodality study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6829758/
https://www.ncbi.nlm.nih.gov/pubmed/31728299
http://dx.doi.org/10.4103/jcecho.jcecho_28_19
work_keys_str_mv AT crestialberto normalvaluesofthemitralaorticintervalvularfibrosathicknessamultimodalitystudy
AT barattapasquale normalvaluesofthemitralaorticintervalvularfibrosathicknessamultimodalitystudy
AT desensifrancesco normalvaluesofthemitralaorticintervalvularfibrosathicknessamultimodalitystudy
AT solarimarco normalvaluesofthemitralaorticintervalvularfibrosathicknessamultimodalitystudy
AT sposatobruno normalvaluesofthemitralaorticintervalvularfibrosathicknessamultimodalitystudy
AT minellistefano normalvaluesofthemitralaorticintervalvularfibrosathicknessamultimodalitystudy
AT cioffinevada normalvaluesofthemitralaorticintervalvularfibrosathicknessamultimodalitystudy
AT franciluca normalvaluesofthemitralaorticintervalvularfibrosathicknessamultimodalitystudy
AT scalesem normalvaluesofthemitralaorticintervalvularfibrosathicknessamultimodalitystudy
AT limbrunougo normalvaluesofthemitralaorticintervalvularfibrosathicknessamultimodalitystudy