Cargando…

“In Vitro” Study About Variables that Influence in Arch Friction with Conventional and Self-Ligating Brackets

Many advantages have been described surrounding self-ligating (SL) brackets compared to metallic conventional ligating (CL) brackets, such as: Less total treatment time, alignment efficiency, patient comfort, plaque retention, and low friction. The objective of this in vitro simulation was to know t...

Descripción completa

Detalles Bibliográficos
Autores principales: Moyano, Javier, Mases, Laia, Izeta, Telmo, Flores, Teresa, Fernández-Bozal, Javier, Gil, Javier, Puigdollers, Andreu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6829865/
https://www.ncbi.nlm.nih.gov/pubmed/31600912
http://dx.doi.org/10.3390/ma12203279
_version_ 1783465658303905792
author Moyano, Javier
Mases, Laia
Izeta, Telmo
Flores, Teresa
Fernández-Bozal, Javier
Gil, Javier
Puigdollers, Andreu
author_facet Moyano, Javier
Mases, Laia
Izeta, Telmo
Flores, Teresa
Fernández-Bozal, Javier
Gil, Javier
Puigdollers, Andreu
author_sort Moyano, Javier
collection PubMed
description Many advantages have been described surrounding self-ligating (SL) brackets compared to metallic conventional ligating (CL) brackets, such as: Less total treatment time, alignment efficiency, patient comfort, plaque retention, and low friction. The objective of this in vitro simulation was to know the variables that affect arch displacement in CL and SL brackets—active (ASL) and passive (PSL)—and analyze if static friction values are affected by bracket design, arch wire section, kind of ligature, and use of a friction reducer agent (FRA) in a wet state. Larger values of static friction were found in CL with metallic ligature (ML) (8.01 ± 1.08 N/mm) and elastic ligature (EL) (6.96 ± 0.48 N/mm). Lower values were found in PSL brackets combined with FRA (0.58 ± 0.21 N/mm). The study was carried out using different stereographical models of a maxillary upper right quadrant with canine, first and second premolar, and first molar bonded brackets. A section of 25 mm of 0.019 × 0.025” stainless steel arch with a rectangular section (SS) and hybrid section (HY) was inserted into the different bracket models. Static friction values were collected using a universal test machine in wet conditions and testing the effect of a friction reducer agent (FRA). To assure the reliability of the study, different wire combinations were repeated after two weeks by the same operator and a linear analysis of regression was done. Each bracket model analysis—with the different wires, use of the FRA, and comparison among brackets in similar conditions—was done using an ANOVA test with a confidence interval of 95% and comparative Post-Hoc tests (LSD). In this in vitro simulation we found higher static friction values in CL compared to ASL and PSL. In PSL, lower values were achieved. CL brackets using ML showed the highest static friction values with a great variability. In this setting, the use of HY wires did not reduce static friction values in ASL and PSL, while in CL brackets with EL friction the values were reduced significantly. An FRA combined with ASL reduced significantly static friction values but not with PSL. In the case of CL, the FRA effect was higher with SS and better than with HY wires. ML values were similar to ASL static friction. The direct extrapolation of the results might be inaccurate, since all these findings should be tested clinically to be validated.
format Online
Article
Text
id pubmed-6829865
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-68298652019-11-18 “In Vitro” Study About Variables that Influence in Arch Friction with Conventional and Self-Ligating Brackets Moyano, Javier Mases, Laia Izeta, Telmo Flores, Teresa Fernández-Bozal, Javier Gil, Javier Puigdollers, Andreu Materials (Basel) Article Many advantages have been described surrounding self-ligating (SL) brackets compared to metallic conventional ligating (CL) brackets, such as: Less total treatment time, alignment efficiency, patient comfort, plaque retention, and low friction. The objective of this in vitro simulation was to know the variables that affect arch displacement in CL and SL brackets—active (ASL) and passive (PSL)—and analyze if static friction values are affected by bracket design, arch wire section, kind of ligature, and use of a friction reducer agent (FRA) in a wet state. Larger values of static friction were found in CL with metallic ligature (ML) (8.01 ± 1.08 N/mm) and elastic ligature (EL) (6.96 ± 0.48 N/mm). Lower values were found in PSL brackets combined with FRA (0.58 ± 0.21 N/mm). The study was carried out using different stereographical models of a maxillary upper right quadrant with canine, first and second premolar, and first molar bonded brackets. A section of 25 mm of 0.019 × 0.025” stainless steel arch with a rectangular section (SS) and hybrid section (HY) was inserted into the different bracket models. Static friction values were collected using a universal test machine in wet conditions and testing the effect of a friction reducer agent (FRA). To assure the reliability of the study, different wire combinations were repeated after two weeks by the same operator and a linear analysis of regression was done. Each bracket model analysis—with the different wires, use of the FRA, and comparison among brackets in similar conditions—was done using an ANOVA test with a confidence interval of 95% and comparative Post-Hoc tests (LSD). In this in vitro simulation we found higher static friction values in CL compared to ASL and PSL. In PSL, lower values were achieved. CL brackets using ML showed the highest static friction values with a great variability. In this setting, the use of HY wires did not reduce static friction values in ASL and PSL, while in CL brackets with EL friction the values were reduced significantly. An FRA combined with ASL reduced significantly static friction values but not with PSL. In the case of CL, the FRA effect was higher with SS and better than with HY wires. ML values were similar to ASL static friction. The direct extrapolation of the results might be inaccurate, since all these findings should be tested clinically to be validated. MDPI 2019-10-09 /pmc/articles/PMC6829865/ /pubmed/31600912 http://dx.doi.org/10.3390/ma12203279 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Moyano, Javier
Mases, Laia
Izeta, Telmo
Flores, Teresa
Fernández-Bozal, Javier
Gil, Javier
Puigdollers, Andreu
“In Vitro” Study About Variables that Influence in Arch Friction with Conventional and Self-Ligating Brackets
title “In Vitro” Study About Variables that Influence in Arch Friction with Conventional and Self-Ligating Brackets
title_full “In Vitro” Study About Variables that Influence in Arch Friction with Conventional and Self-Ligating Brackets
title_fullStr “In Vitro” Study About Variables that Influence in Arch Friction with Conventional and Self-Ligating Brackets
title_full_unstemmed “In Vitro” Study About Variables that Influence in Arch Friction with Conventional and Self-Ligating Brackets
title_short “In Vitro” Study About Variables that Influence in Arch Friction with Conventional and Self-Ligating Brackets
title_sort “in vitro” study about variables that influence in arch friction with conventional and self-ligating brackets
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6829865/
https://www.ncbi.nlm.nih.gov/pubmed/31600912
http://dx.doi.org/10.3390/ma12203279
work_keys_str_mv AT moyanojavier invitrostudyaboutvariablesthatinfluenceinarchfrictionwithconventionalandselfligatingbrackets
AT maseslaia invitrostudyaboutvariablesthatinfluenceinarchfrictionwithconventionalandselfligatingbrackets
AT izetatelmo invitrostudyaboutvariablesthatinfluenceinarchfrictionwithconventionalandselfligatingbrackets
AT floresteresa invitrostudyaboutvariablesthatinfluenceinarchfrictionwithconventionalandselfligatingbrackets
AT fernandezbozaljavier invitrostudyaboutvariablesthatinfluenceinarchfrictionwithconventionalandselfligatingbrackets
AT giljavier invitrostudyaboutvariablesthatinfluenceinarchfrictionwithconventionalandselfligatingbrackets
AT puigdollersandreu invitrostudyaboutvariablesthatinfluenceinarchfrictionwithconventionalandselfligatingbrackets