Cargando…

Costs of switching to low global warming potential inhalers. An economic and carbon footprint analysis of NHS prescription data in England

OBJECTIVES: Metered-dose inhalers (MDIs) contain propellants which are potent greenhouse gases. Many agencies propose a switch to alternative, low global warming potential (GWP) inhalers, such as dry powder inhalers (DPIs). We aimed to analyse the impact on greenhouse gas emissions and drug costs of...

Descripción completa

Detalles Bibliográficos
Autores principales: Wilkinson, Alexander J K, Braggins, Rory, Steinbach, Ingeborg, Smith, James
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6830591/
https://www.ncbi.nlm.nih.gov/pubmed/31662306
http://dx.doi.org/10.1136/bmjopen-2018-028763
_version_ 1783465795953623040
author Wilkinson, Alexander J K
Braggins, Rory
Steinbach, Ingeborg
Smith, James
author_facet Wilkinson, Alexander J K
Braggins, Rory
Steinbach, Ingeborg
Smith, James
author_sort Wilkinson, Alexander J K
collection PubMed
description OBJECTIVES: Metered-dose inhalers (MDIs) contain propellants which are potent greenhouse gases. Many agencies propose a switch to alternative, low global warming potential (GWP) inhalers, such as dry powder inhalers (DPIs). We aimed to analyse the impact on greenhouse gas emissions and drug costs of making this switch. SETTING: We studied National Health Service prescription data from England in 2017 and collated carbon footprint data on inhalers commonly used in England. DESIGN: Inhalers were separated into different categories according to their mechanisms of action (eg, short-acting beta-agonist). Within each category we identified low and high GWP inhalers and calculated the cost and carbon impact of changing to low GWP inhalers. We modelled scenarios for swapping proportionally according to the current market share of each equivalent DPI (model 1) and switching to the lowest cost pharmaceutically equivalent DPI (model 2). We also reviewed available data on the carbon footprint of inhalers from scientific publications, independently certified reports and patents to provide more accurate carbon footprint information on different types of inhalers. RESULTS: If MDIs using HFA propellant are replaced with the cheapest equivalent DPI, then for every 10% of MDIs changed to DPIs, drug costs decrease by £8.2M annually. However if the brands of DPIs stay the same as 2017 prescribing patterns, for every 10% of MDIs changed to DPIs, drug costs increase by £12.7M annually. Most potential savings are due to less expensive long-acting beta-agonist (LABA)/inhaled corticosteroids (ICS) inhalers. Some reliever inhalers (eg, Ventolin) have a carbon footprint over 25 kg CO(2)e per inhaler, while others use far less 1,1,1,2-tetrafluoroethane (HFA134a) (eg, Salamol) with a carbon footprint of <10 kg CO(2)e per inhaler. 1,1,1,2,3,3,3-Heptafluoropropane (HFA227ea) LABA/ICS inhalers (eg, Flutiform) have a carbon footprint over 36 kg CO(2)e, compared with an equivalent HFA134a combination inhaler (eg, Fostair) at <20 kg CO(2)e. For every 10% of MDIs changed to DPIs, 58 kt CO(2)e could be saved annually in England. CONCLUSIONS: Switching to DPIs would result in large carbon savings and can be achieved alongside reduced drug costs by using less expensive brands. Substantial carbon savings can be made by using small volume HFA134a MDIs, in preference to large volume HFA134a MDIs, or those containing HFA227ea as a propellant.
format Online
Article
Text
id pubmed-6830591
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-68305912019-11-20 Costs of switching to low global warming potential inhalers. An economic and carbon footprint analysis of NHS prescription data in England Wilkinson, Alexander J K Braggins, Rory Steinbach, Ingeborg Smith, James BMJ Open Respiratory Medicine OBJECTIVES: Metered-dose inhalers (MDIs) contain propellants which are potent greenhouse gases. Many agencies propose a switch to alternative, low global warming potential (GWP) inhalers, such as dry powder inhalers (DPIs). We aimed to analyse the impact on greenhouse gas emissions and drug costs of making this switch. SETTING: We studied National Health Service prescription data from England in 2017 and collated carbon footprint data on inhalers commonly used in England. DESIGN: Inhalers were separated into different categories according to their mechanisms of action (eg, short-acting beta-agonist). Within each category we identified low and high GWP inhalers and calculated the cost and carbon impact of changing to low GWP inhalers. We modelled scenarios for swapping proportionally according to the current market share of each equivalent DPI (model 1) and switching to the lowest cost pharmaceutically equivalent DPI (model 2). We also reviewed available data on the carbon footprint of inhalers from scientific publications, independently certified reports and patents to provide more accurate carbon footprint information on different types of inhalers. RESULTS: If MDIs using HFA propellant are replaced with the cheapest equivalent DPI, then for every 10% of MDIs changed to DPIs, drug costs decrease by £8.2M annually. However if the brands of DPIs stay the same as 2017 prescribing patterns, for every 10% of MDIs changed to DPIs, drug costs increase by £12.7M annually. Most potential savings are due to less expensive long-acting beta-agonist (LABA)/inhaled corticosteroids (ICS) inhalers. Some reliever inhalers (eg, Ventolin) have a carbon footprint over 25 kg CO(2)e per inhaler, while others use far less 1,1,1,2-tetrafluoroethane (HFA134a) (eg, Salamol) with a carbon footprint of <10 kg CO(2)e per inhaler. 1,1,1,2,3,3,3-Heptafluoropropane (HFA227ea) LABA/ICS inhalers (eg, Flutiform) have a carbon footprint over 36 kg CO(2)e, compared with an equivalent HFA134a combination inhaler (eg, Fostair) at <20 kg CO(2)e. For every 10% of MDIs changed to DPIs, 58 kt CO(2)e could be saved annually in England. CONCLUSIONS: Switching to DPIs would result in large carbon savings and can be achieved alongside reduced drug costs by using less expensive brands. Substantial carbon savings can be made by using small volume HFA134a MDIs, in preference to large volume HFA134a MDIs, or those containing HFA227ea as a propellant. BMJ Publishing Group 2019-10-29 /pmc/articles/PMC6830591/ /pubmed/31662306 http://dx.doi.org/10.1136/bmjopen-2018-028763 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Respiratory Medicine
Wilkinson, Alexander J K
Braggins, Rory
Steinbach, Ingeborg
Smith, James
Costs of switching to low global warming potential inhalers. An economic and carbon footprint analysis of NHS prescription data in England
title Costs of switching to low global warming potential inhalers. An economic and carbon footprint analysis of NHS prescription data in England
title_full Costs of switching to low global warming potential inhalers. An economic and carbon footprint analysis of NHS prescription data in England
title_fullStr Costs of switching to low global warming potential inhalers. An economic and carbon footprint analysis of NHS prescription data in England
title_full_unstemmed Costs of switching to low global warming potential inhalers. An economic and carbon footprint analysis of NHS prescription data in England
title_short Costs of switching to low global warming potential inhalers. An economic and carbon footprint analysis of NHS prescription data in England
title_sort costs of switching to low global warming potential inhalers. an economic and carbon footprint analysis of nhs prescription data in england
topic Respiratory Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6830591/
https://www.ncbi.nlm.nih.gov/pubmed/31662306
http://dx.doi.org/10.1136/bmjopen-2018-028763
work_keys_str_mv AT wilkinsonalexanderjk costsofswitchingtolowglobalwarmingpotentialinhalersaneconomicandcarbonfootprintanalysisofnhsprescriptiondatainengland
AT bragginsrory costsofswitchingtolowglobalwarmingpotentialinhalersaneconomicandcarbonfootprintanalysisofnhsprescriptiondatainengland
AT steinbachingeborg costsofswitchingtolowglobalwarmingpotentialinhalersaneconomicandcarbonfootprintanalysisofnhsprescriptiondatainengland
AT smithjames costsofswitchingtolowglobalwarmingpotentialinhalersaneconomicandcarbonfootprintanalysisofnhsprescriptiondatainengland