Cargando…
Short implants (≤6 mm) versus longer implants with sinus floor elevation in atrophic posterior maxilla: a systematic review and meta-analysis
OBJECTIVES: To compare the use of short implants (≤6 mm) in atrophic posterior maxilla versus longer implants (≥10 mm) with sinus floor elevation. DESIGN: A systematic review and meta-analysis based on randomised controlled trials (RCTs). DATA SOURCES: Electronic searches were conducted in PubMed, E...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6830603/ https://www.ncbi.nlm.nih.gov/pubmed/31662363 http://dx.doi.org/10.1136/bmjopen-2019-029826 |
Sumario: | OBJECTIVES: To compare the use of short implants (≤6 mm) in atrophic posterior maxilla versus longer implants (≥10 mm) with sinus floor elevation. DESIGN: A systematic review and meta-analysis based on randomised controlled trials (RCTs). DATA SOURCES: Electronic searches were conducted in PubMed, Embase and the Cochrane CENTRAL. Retrospective and prospective hand searches were also performed. ELIGIBILITY CRITERIA: RCTs comparing short implants (≤6 mm) and longer implants (≥10 mm) with sinus floor elevation were included. Outcome measures included implant survival (primary outcome), marginal bone loss (MBL), complications and patient satisfaction. DATA EXTRACTION AND SYNTHESIS: Risks of bias in and across studies were evaluated. Meta-analysis, subgroup analysis and sensitivity analysis were undertaken. Quality of evidence was assessed according to Grading of Recommendations Assessment, Development and Evaluation. RESULTS: A total of seven RCTs involving 310 participants were included. No significant difference in survival rate was found for 1–3 years follow-up (RR 1.01, 95% CI 0.97 to 1.04, p=0.74, I²=0%, moderate-quality evidence) or for 3 years or longer follow-up (RR 1.00, 95% CI 0.97 to 1.04, p=0.79, I²=0%, moderate-quality evidence). However, short implants (≤6 mm) showed significantly less MBL in 1–3 years follow-up (MD=−0.13 mm, 95% CI −0.21 to 0.05; p=0.001, I²=87%, low-quality evidence) and in 3 years or longer follow-up (MD=−0.25 mm, 95% CI −0.40 to 0.10; p=0.001, I²=0%, moderate-quality evidence). In addition, short implant (≤6 mm) resulted in fewer postsurgery reaction (RR 0.11, 95% CI 0.14 to 0.31, p<0.001, I²=40%, moderate-quality evidence) and sinus perforation or infection (RR 0.11, 95% CI 0.02 to 0.63, p=0.01, I²=0%, moderate-quality evidence). CONCLUSIONS: For atrophic posterior maxilla, short implants (≤6 mm) are a promising alternative to sinus floor elevation, with comparable survival rate, less MBL and postsurgery reactions. Additional high-quality studies are needed to evaluate the long-term effectiveness of short implants (≤6 mm). TRIAL REGISTERATION NUMBER: The protocol has been registered at PROSPERO (CRD42018103531). |
---|