OBJECTIVES: The aim of this study was to investigate the effectiveness of the proximal humeral internal locking system (PHILOS) plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures. METHODS: A total of 112 patients with proximal humerus fractures were...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Xiong, Yu, Zheng-Xi, Wang, Huai-Yun, Shen, Feng, Lin, Guo-Bing, Wang, Sheng, Yin, Zong-Sheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6831283/
https://www.ncbi.nlm.nih.gov/pubmed/31027081
http://dx.doi.org/10.1097/MD.0000000000015271
_version_ 1783465933519454208
author Chen, Xiong
Yu, Zheng-Xi
Wang, Huai-Yun
Shen, Feng
Lin, Guo-Bing
Wang, Sheng
Yin, Zong-Sheng
author_facet Chen, Xiong
Yu, Zheng-Xi
Wang, Huai-Yun
Shen, Feng
Lin, Guo-Bing
Wang, Sheng
Yin, Zong-Sheng
author_sort Chen, Xiong
collection PubMed
description OBJECTIVES: The aim of this study was to investigate the effectiveness of the proximal humeral internal locking system (PHILOS) plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures. METHODS: A total of 112 patients with proximal humerus fractures were assigned randomly into 2 groups. Group A (n = 56) was treated by open reduction and internal fixation (ORIF) with a PHILOS plate; group B (n = 56) was treated by ORIF with a PHILOS plate in combination with the use of a custom neutral-position shoulder and elbow sling for 30 days after surgery. The incidence of internal fixation failure, the Constant–Murley shoulder assessment, and Visual Analogue Scale (VAS) score were recorded and analyzed. RESULTS: Patients included were followed up for an average of 15 months (range, 6–24 months). No significant differences were observed in mean VAS scores and mean Constant–Murley shoulder assessment scores at 1-day preoperative and postoperative day 3 between groups A and B. However, mean VAS scores and mean Constant–Murley shoulder assessment in group B were significantly improved when compared with group A at postoperative day 30 and the final follow-up. No cases of postoperative infection, loss of reduction, PHILOS break, or vascular nerve injury occurred in either group. CONCLUSIONS: Proximal humerus fractures treated with the combination of the PHILOS and custom neutral-position shoulder and elbow sling for 30 days after operation was associated with a lower incidence of internal fixation failure. There was no increase in adverse events compared with open reduction and internal fixation with a PHILOS plate alone.
format Online
Article
Text
id pubmed-6831283
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-68312832019-11-19 Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study Chen, Xiong Yu, Zheng-Xi Wang, Huai-Yun Shen, Feng Lin, Guo-Bing Wang, Sheng Yin, Zong-Sheng Medicine (Baltimore) 7100 OBJECTIVES: The aim of this study was to investigate the effectiveness of the proximal humeral internal locking system (PHILOS) plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures. METHODS: A total of 112 patients with proximal humerus fractures were assigned randomly into 2 groups. Group A (n = 56) was treated by open reduction and internal fixation (ORIF) with a PHILOS plate; group B (n = 56) was treated by ORIF with a PHILOS plate in combination with the use of a custom neutral-position shoulder and elbow sling for 30 days after surgery. The incidence of internal fixation failure, the Constant–Murley shoulder assessment, and Visual Analogue Scale (VAS) score were recorded and analyzed. RESULTS: Patients included were followed up for an average of 15 months (range, 6–24 months). No significant differences were observed in mean VAS scores and mean Constant–Murley shoulder assessment scores at 1-day preoperative and postoperative day 3 between groups A and B. However, mean VAS scores and mean Constant–Murley shoulder assessment in group B were significantly improved when compared with group A at postoperative day 30 and the final follow-up. No cases of postoperative infection, loss of reduction, PHILOS break, or vascular nerve injury occurred in either group. CONCLUSIONS: Proximal humerus fractures treated with the combination of the PHILOS and custom neutral-position shoulder and elbow sling for 30 days after operation was associated with a lower incidence of internal fixation failure. There was no increase in adverse events compared with open reduction and internal fixation with a PHILOS plate alone. Wolters Kluwer Health 2019-04-26 /pmc/articles/PMC6831283/ /pubmed/31027081 http://dx.doi.org/10.1097/MD.0000000000015271 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle 7100
Chen, Xiong
Yu, Zheng-Xi
Wang, Huai-Yun
Shen, Feng
Lin, Guo-Bing
Wang, Sheng
Yin, Zong-Sheng
Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study
title Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study
title_full Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study
title_fullStr Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study
title_full_unstemmed Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study
title_short Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study
title_sort proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: a randomized study
topic 7100
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6831283/
https://www.ncbi.nlm.nih.gov/pubmed/31027081
http://dx.doi.org/10.1097/MD.0000000000015271
work_keys_str_mv AT chenxiong proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy
AT yuzhengxi proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy
AT wanghuaiyun proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy
AT shenfeng proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy
AT linguobing proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy
AT wangsheng proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy
AT yinzongsheng proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy