Cargando…
Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study
OBJECTIVES: The aim of this study was to investigate the effectiveness of the proximal humeral internal locking system (PHILOS) plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures. METHODS: A total of 112 patients with proximal humerus fractures were...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6831283/ https://www.ncbi.nlm.nih.gov/pubmed/31027081 http://dx.doi.org/10.1097/MD.0000000000015271 |
_version_ | 1783465933519454208 |
---|---|
author | Chen, Xiong Yu, Zheng-Xi Wang, Huai-Yun Shen, Feng Lin, Guo-Bing Wang, Sheng Yin, Zong-Sheng |
author_facet | Chen, Xiong Yu, Zheng-Xi Wang, Huai-Yun Shen, Feng Lin, Guo-Bing Wang, Sheng Yin, Zong-Sheng |
author_sort | Chen, Xiong |
collection | PubMed |
description | OBJECTIVES: The aim of this study was to investigate the effectiveness of the proximal humeral internal locking system (PHILOS) plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures. METHODS: A total of 112 patients with proximal humerus fractures were assigned randomly into 2 groups. Group A (n = 56) was treated by open reduction and internal fixation (ORIF) with a PHILOS plate; group B (n = 56) was treated by ORIF with a PHILOS plate in combination with the use of a custom neutral-position shoulder and elbow sling for 30 days after surgery. The incidence of internal fixation failure, the Constant–Murley shoulder assessment, and Visual Analogue Scale (VAS) score were recorded and analyzed. RESULTS: Patients included were followed up for an average of 15 months (range, 6–24 months). No significant differences were observed in mean VAS scores and mean Constant–Murley shoulder assessment scores at 1-day preoperative and postoperative day 3 between groups A and B. However, mean VAS scores and mean Constant–Murley shoulder assessment in group B were significantly improved when compared with group A at postoperative day 30 and the final follow-up. No cases of postoperative infection, loss of reduction, PHILOS break, or vascular nerve injury occurred in either group. CONCLUSIONS: Proximal humerus fractures treated with the combination of the PHILOS and custom neutral-position shoulder and elbow sling for 30 days after operation was associated with a lower incidence of internal fixation failure. There was no increase in adverse events compared with open reduction and internal fixation with a PHILOS plate alone. |
format | Online Article Text |
id | pubmed-6831283 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-68312832019-11-19 Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study Chen, Xiong Yu, Zheng-Xi Wang, Huai-Yun Shen, Feng Lin, Guo-Bing Wang, Sheng Yin, Zong-Sheng Medicine (Baltimore) 7100 OBJECTIVES: The aim of this study was to investigate the effectiveness of the proximal humeral internal locking system (PHILOS) plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures. METHODS: A total of 112 patients with proximal humerus fractures were assigned randomly into 2 groups. Group A (n = 56) was treated by open reduction and internal fixation (ORIF) with a PHILOS plate; group B (n = 56) was treated by ORIF with a PHILOS plate in combination with the use of a custom neutral-position shoulder and elbow sling for 30 days after surgery. The incidence of internal fixation failure, the Constant–Murley shoulder assessment, and Visual Analogue Scale (VAS) score were recorded and analyzed. RESULTS: Patients included were followed up for an average of 15 months (range, 6–24 months). No significant differences were observed in mean VAS scores and mean Constant–Murley shoulder assessment scores at 1-day preoperative and postoperative day 3 between groups A and B. However, mean VAS scores and mean Constant–Murley shoulder assessment in group B were significantly improved when compared with group A at postoperative day 30 and the final follow-up. No cases of postoperative infection, loss of reduction, PHILOS break, or vascular nerve injury occurred in either group. CONCLUSIONS: Proximal humerus fractures treated with the combination of the PHILOS and custom neutral-position shoulder and elbow sling for 30 days after operation was associated with a lower incidence of internal fixation failure. There was no increase in adverse events compared with open reduction and internal fixation with a PHILOS plate alone. Wolters Kluwer Health 2019-04-26 /pmc/articles/PMC6831283/ /pubmed/31027081 http://dx.doi.org/10.1097/MD.0000000000015271 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 |
spellingShingle | 7100 Chen, Xiong Yu, Zheng-Xi Wang, Huai-Yun Shen, Feng Lin, Guo-Bing Wang, Sheng Yin, Zong-Sheng Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study |
title | Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study |
title_full | Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study |
title_fullStr | Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study |
title_full_unstemmed | Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study |
title_short | Proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: A randomized study |
title_sort | proximal humeral internal locking plate combined with a custom neutral-position shoulder and elbow sling for proximal humerus fractures: a randomized study |
topic | 7100 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6831283/ https://www.ncbi.nlm.nih.gov/pubmed/31027081 http://dx.doi.org/10.1097/MD.0000000000015271 |
work_keys_str_mv | AT chenxiong proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy AT yuzhengxi proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy AT wanghuaiyun proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy AT shenfeng proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy AT linguobing proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy AT wangsheng proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy AT yinzongsheng proximalhumeralinternallockingplatecombinedwithacustomneutralpositionshoulderandelbowslingforproximalhumerusfracturesarandomizedstudy |