Cargando…

Successful blind lung isolation with the use of a novel double-lumen endobronchial tube in a patient undergoing lung transplantation with massive pulmonary secretion: A case report

RATIONALE: Precise lung isolation technique with visual confirmation is essential for thoracic surgeries to create a safe and clear surgical field. However, in certain situations, such as when patients have massive pulmonary secretion or when the fiberoptic bronchoscopy (FOB) is not applicable, lung...

Descripción completa

Detalles Bibliográficos
Autores principales: Seo, Yijun, Kim, Namo, Paik, Hyo Chae, Park, Dahee, Oh, Young Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6831326/
https://www.ncbi.nlm.nih.gov/pubmed/31415423
http://dx.doi.org/10.1097/MD.0000000000016869
_version_ 1783465943799693312
author Seo, Yijun
Kim, Namo
Paik, Hyo Chae
Park, Dahee
Oh, Young Jun
author_facet Seo, Yijun
Kim, Namo
Paik, Hyo Chae
Park, Dahee
Oh, Young Jun
author_sort Seo, Yijun
collection PubMed
description RATIONALE: Precise lung isolation technique with visual confirmation is essential for thoracic surgeries to create a safe and clear surgical field. However, in certain situations, such as when patients have massive pulmonary secretion or when the fiberoptic bronchoscopy (FOB) is not applicable, lung isolation has been performed blindly. PATIENT CONCERN: A 52-year-old woman, whose airway was unable to visualize with FOB due to massive pulmonary secretion, was presented for bilateral sequential lung transplantation. Extracorporeal membranous oxygenation, tracheostomy, and mechanical ventilation were applied to the patient for 39 days preoperatively as a bridge for lung transplantation. DIAGNOSIS: Patient was diagnosed with an idiopathic pulmonary fibrosis and obesity. INTERVENTION: Initially, height-based blind positioning with a conventional double-lumen endobronchial tube (DLT) failed to ventilate the patient properly, and the confirmation of DLT positioning with FOB was impossible due to massive pulmonary secretion. Therefore, a novel DLT (ANKOR DLT) that has one more cuff, located at a point between the distal opening of the tracheal lumen and the starting point of bronchial cuff, than conventional DLT was used for the lung isolation in the patient. OUTCOMES: After the completion of lung graft, FOB finding showed that the ANKOR DLT was optimally positioned at the tracheobronchial tree of the patient, and its depth was 2.5 cm shallower than that of the conventional tube. LESSONS: ANKOR DLT would be a feasible choice to achieve successful blind lung isolation when the use of FOB is impossible to achieve the optimal lung isolation.
format Online
Article
Text
id pubmed-6831326
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-68313262019-11-19 Successful blind lung isolation with the use of a novel double-lumen endobronchial tube in a patient undergoing lung transplantation with massive pulmonary secretion: A case report Seo, Yijun Kim, Namo Paik, Hyo Chae Park, Dahee Oh, Young Jun Medicine (Baltimore) 3300 RATIONALE: Precise lung isolation technique with visual confirmation is essential for thoracic surgeries to create a safe and clear surgical field. However, in certain situations, such as when patients have massive pulmonary secretion or when the fiberoptic bronchoscopy (FOB) is not applicable, lung isolation has been performed blindly. PATIENT CONCERN: A 52-year-old woman, whose airway was unable to visualize with FOB due to massive pulmonary secretion, was presented for bilateral sequential lung transplantation. Extracorporeal membranous oxygenation, tracheostomy, and mechanical ventilation were applied to the patient for 39 days preoperatively as a bridge for lung transplantation. DIAGNOSIS: Patient was diagnosed with an idiopathic pulmonary fibrosis and obesity. INTERVENTION: Initially, height-based blind positioning with a conventional double-lumen endobronchial tube (DLT) failed to ventilate the patient properly, and the confirmation of DLT positioning with FOB was impossible due to massive pulmonary secretion. Therefore, a novel DLT (ANKOR DLT) that has one more cuff, located at a point between the distal opening of the tracheal lumen and the starting point of bronchial cuff, than conventional DLT was used for the lung isolation in the patient. OUTCOMES: After the completion of lung graft, FOB finding showed that the ANKOR DLT was optimally positioned at the tracheobronchial tree of the patient, and its depth was 2.5 cm shallower than that of the conventional tube. LESSONS: ANKOR DLT would be a feasible choice to achieve successful blind lung isolation when the use of FOB is impossible to achieve the optimal lung isolation. Wolters Kluwer Health 2019-08-16 /pmc/articles/PMC6831326/ /pubmed/31415423 http://dx.doi.org/10.1097/MD.0000000000016869 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
spellingShingle 3300
Seo, Yijun
Kim, Namo
Paik, Hyo Chae
Park, Dahee
Oh, Young Jun
Successful blind lung isolation with the use of a novel double-lumen endobronchial tube in a patient undergoing lung transplantation with massive pulmonary secretion: A case report
title Successful blind lung isolation with the use of a novel double-lumen endobronchial tube in a patient undergoing lung transplantation with massive pulmonary secretion: A case report
title_full Successful blind lung isolation with the use of a novel double-lumen endobronchial tube in a patient undergoing lung transplantation with massive pulmonary secretion: A case report
title_fullStr Successful blind lung isolation with the use of a novel double-lumen endobronchial tube in a patient undergoing lung transplantation with massive pulmonary secretion: A case report
title_full_unstemmed Successful blind lung isolation with the use of a novel double-lumen endobronchial tube in a patient undergoing lung transplantation with massive pulmonary secretion: A case report
title_short Successful blind lung isolation with the use of a novel double-lumen endobronchial tube in a patient undergoing lung transplantation with massive pulmonary secretion: A case report
title_sort successful blind lung isolation with the use of a novel double-lumen endobronchial tube in a patient undergoing lung transplantation with massive pulmonary secretion: a case report
topic 3300
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6831326/
https://www.ncbi.nlm.nih.gov/pubmed/31415423
http://dx.doi.org/10.1097/MD.0000000000016869
work_keys_str_mv AT seoyijun successfulblindlungisolationwiththeuseofanoveldoublelumenendobronchialtubeinapatientundergoinglungtransplantationwithmassivepulmonarysecretionacasereport
AT kimnamo successfulblindlungisolationwiththeuseofanoveldoublelumenendobronchialtubeinapatientundergoinglungtransplantationwithmassivepulmonarysecretionacasereport
AT paikhyochae successfulblindlungisolationwiththeuseofanoveldoublelumenendobronchialtubeinapatientundergoinglungtransplantationwithmassivepulmonarysecretionacasereport
AT parkdahee successfulblindlungisolationwiththeuseofanoveldoublelumenendobronchialtubeinapatientundergoinglungtransplantationwithmassivepulmonarysecretionacasereport
AT ohyoungjun successfulblindlungisolationwiththeuseofanoveldoublelumenendobronchialtubeinapatientundergoinglungtransplantationwithmassivepulmonarysecretionacasereport