Cargando…

Signal-to-background ratio and lateral resolution in deep tissue imaging by optical coherence microscopy in the 1700 nm spectral band

We quantitatively investigated the image quality in deep tissue imaging with optical coherence microscopy (OCM) in the 1700 nm spectral band, in terms of the signal-to-background ratio (SBR) and lateral resolution. In this work, to demonstrate the benefits of using the 1700 nm spectral band for OCM...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamanaka, Masahito, Hayakawa, Naoki, Nishizawa, Norihiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6831679/
https://www.ncbi.nlm.nih.gov/pubmed/31690729
http://dx.doi.org/10.1038/s41598-019-52175-9
_version_ 1783466025150316544
author Yamanaka, Masahito
Hayakawa, Naoki
Nishizawa, Norihiko
author_facet Yamanaka, Masahito
Hayakawa, Naoki
Nishizawa, Norihiko
author_sort Yamanaka, Masahito
collection PubMed
description We quantitatively investigated the image quality in deep tissue imaging with optical coherence microscopy (OCM) in the 1700 nm spectral band, in terms of the signal-to-background ratio (SBR) and lateral resolution. In this work, to demonstrate the benefits of using the 1700 nm spectral band for OCM imaging of brain samples, we compared the imaging quality of OCM en-face images obtained at the same position by using a hybrid 1300 nm/1700 nm spectral domain (SD) OCM system with shared sample and reference arms. By observing a reflective resolution test target through a 1.5 mm-thick tissue phantom, which had a similar scattering coefficient to brain cortex tissue, we confirmed that 1700 nm OCM achieved an SBR about 6-times higher than 1300 nm OCM, although the lateral resolution of the both OCMs was similarly degraded with the increase of the imaging depth. Finally, we also demonstrated high-contrast deep tissue imaging of a mouse brain at a depth up to 1.8 mm by using high-resolution 1700 nm SD-OCM.
format Online
Article
Text
id pubmed-6831679
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-68316792019-11-13 Signal-to-background ratio and lateral resolution in deep tissue imaging by optical coherence microscopy in the 1700 nm spectral band Yamanaka, Masahito Hayakawa, Naoki Nishizawa, Norihiko Sci Rep Article We quantitatively investigated the image quality in deep tissue imaging with optical coherence microscopy (OCM) in the 1700 nm spectral band, in terms of the signal-to-background ratio (SBR) and lateral resolution. In this work, to demonstrate the benefits of using the 1700 nm spectral band for OCM imaging of brain samples, we compared the imaging quality of OCM en-face images obtained at the same position by using a hybrid 1300 nm/1700 nm spectral domain (SD) OCM system with shared sample and reference arms. By observing a reflective resolution test target through a 1.5 mm-thick tissue phantom, which had a similar scattering coefficient to brain cortex tissue, we confirmed that 1700 nm OCM achieved an SBR about 6-times higher than 1300 nm OCM, although the lateral resolution of the both OCMs was similarly degraded with the increase of the imaging depth. Finally, we also demonstrated high-contrast deep tissue imaging of a mouse brain at a depth up to 1.8 mm by using high-resolution 1700 nm SD-OCM. Nature Publishing Group UK 2019-11-05 /pmc/articles/PMC6831679/ /pubmed/31690729 http://dx.doi.org/10.1038/s41598-019-52175-9 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Yamanaka, Masahito
Hayakawa, Naoki
Nishizawa, Norihiko
Signal-to-background ratio and lateral resolution in deep tissue imaging by optical coherence microscopy in the 1700 nm spectral band
title Signal-to-background ratio and lateral resolution in deep tissue imaging by optical coherence microscopy in the 1700 nm spectral band
title_full Signal-to-background ratio and lateral resolution in deep tissue imaging by optical coherence microscopy in the 1700 nm spectral band
title_fullStr Signal-to-background ratio and lateral resolution in deep tissue imaging by optical coherence microscopy in the 1700 nm spectral band
title_full_unstemmed Signal-to-background ratio and lateral resolution in deep tissue imaging by optical coherence microscopy in the 1700 nm spectral band
title_short Signal-to-background ratio and lateral resolution in deep tissue imaging by optical coherence microscopy in the 1700 nm spectral band
title_sort signal-to-background ratio and lateral resolution in deep tissue imaging by optical coherence microscopy in the 1700 nm spectral band
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6831679/
https://www.ncbi.nlm.nih.gov/pubmed/31690729
http://dx.doi.org/10.1038/s41598-019-52175-9
work_keys_str_mv AT yamanakamasahito signaltobackgroundratioandlateralresolutionindeeptissueimagingbyopticalcoherencemicroscopyinthe1700nmspectralband
AT hayakawanaoki signaltobackgroundratioandlateralresolutionindeeptissueimagingbyopticalcoherencemicroscopyinthe1700nmspectralband
AT nishizawanorihiko signaltobackgroundratioandlateralresolutionindeeptissueimagingbyopticalcoherencemicroscopyinthe1700nmspectralband