INTRODUCTION: Total hip arthroplasty in young patients can cause problems when it comes to choosing a suitable implant. The Birmingham Mid-Head Resection prosthesis (BMHR) offers the option of preserving bone stock despite its poor quality in the femoral neck. Femoral neck fractures are a known comp...

Descripción completa

Detalles Bibliográficos
Autores principales: Fraile Gamarra, Inés, Jiménez Viseu Pinheiro, Juan Fernando, Cano Gala, Carlos, Blanco Blanco, Juan Francisco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6831797/
https://www.ncbi.nlm.nih.gov/pubmed/31669908
http://dx.doi.org/10.1016/j.ijscr.2019.10.012
_version_ 1783466052960649216
author Fraile Gamarra, Inés
Jiménez Viseu Pinheiro, Juan Fernando
Cano Gala, Carlos
Blanco Blanco, Juan Francisco
author_facet Fraile Gamarra, Inés
Jiménez Viseu Pinheiro, Juan Fernando
Cano Gala, Carlos
Blanco Blanco, Juan Francisco
author_sort Fraile Gamarra, Inés
collection PubMed
description INTRODUCTION: Total hip arthroplasty in young patients can cause problems when it comes to choosing a suitable implant. The Birmingham Mid-Head Resection prosthesis (BMHR) offers the option of preserving bone stock despite its poor quality in the femoral neck. Femoral neck fractures are a known complication of hip resurfacing prostheses and the main reason for revision surgery. Retaining the femoral implant may cause difficulties in osteosynthesis carried out with implants habitually used for intertrochanteric or femoral neck fractures (e.g., a screw-plate device or a cephalomedullary nail) [2]. PRESENTATION OF CASE: We present the case of an 81-year-old patient who underwent surgery for right hip osteoarthritis and received a Birmingham Mid-Head Resection prosthesis. She had no history of previous fractures due to frailty. While on holiday, she sustained a periprosthetic fracture as a result of a fall. While the most common fracture in resurfacing prosthesis is produced in the femoral neck, in this case the patient sustained a subtrochanteric fracture. This fracture was surgically treated by means of open reduction and internal fixation with trochanteric plate and three cerclages. DISCUSSION: Olsen et al. [8] described two fracture patterns: transcervical vertical shear type and subcapital type. In our patient's case, the fracture pattern was different to those described, as the fracture started in the cervical area and reached the subtrochanteric area. This change in the standard periprosthetic fracture pattern leads to a change in the therapeutic attitude that must be adopted. CONCLUSION: BMHR prostheses are metal-on-metal implants that resulted from the development of the standard resurfacing prostheses used to treat hip osteoarthritis in young patients with the goal of preserving as much bone stock as possible. In this paper we will describe a rare complication in this type of prosthesis and how it was surgically treated after reviewing the available literature.
format Online
Article
Text
id pubmed-6831797
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-68317972019-11-07 Birmingham mid-head resection periprosthetic fractures: Case report Fraile Gamarra, Inés Jiménez Viseu Pinheiro, Juan Fernando Cano Gala, Carlos Blanco Blanco, Juan Francisco Int J Surg Case Rep Article INTRODUCTION: Total hip arthroplasty in young patients can cause problems when it comes to choosing a suitable implant. The Birmingham Mid-Head Resection prosthesis (BMHR) offers the option of preserving bone stock despite its poor quality in the femoral neck. Femoral neck fractures are a known complication of hip resurfacing prostheses and the main reason for revision surgery. Retaining the femoral implant may cause difficulties in osteosynthesis carried out with implants habitually used for intertrochanteric or femoral neck fractures (e.g., a screw-plate device or a cephalomedullary nail) [2]. PRESENTATION OF CASE: We present the case of an 81-year-old patient who underwent surgery for right hip osteoarthritis and received a Birmingham Mid-Head Resection prosthesis. She had no history of previous fractures due to frailty. While on holiday, she sustained a periprosthetic fracture as a result of a fall. While the most common fracture in resurfacing prosthesis is produced in the femoral neck, in this case the patient sustained a subtrochanteric fracture. This fracture was surgically treated by means of open reduction and internal fixation with trochanteric plate and three cerclages. DISCUSSION: Olsen et al. [8] described two fracture patterns: transcervical vertical shear type and subcapital type. In our patient's case, the fracture pattern was different to those described, as the fracture started in the cervical area and reached the subtrochanteric area. This change in the standard periprosthetic fracture pattern leads to a change in the therapeutic attitude that must be adopted. CONCLUSION: BMHR prostheses are metal-on-metal implants that resulted from the development of the standard resurfacing prostheses used to treat hip osteoarthritis in young patients with the goal of preserving as much bone stock as possible. In this paper we will describe a rare complication in this type of prosthesis and how it was surgically treated after reviewing the available literature. Elsevier 2019-10-12 /pmc/articles/PMC6831797/ /pubmed/31669908 http://dx.doi.org/10.1016/j.ijscr.2019.10.012 Text en © 2019 Published by Elsevier Ltd on behalf of IJS Publishing Group Ltd. http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Fraile Gamarra, Inés
Jiménez Viseu Pinheiro, Juan Fernando
Cano Gala, Carlos
Blanco Blanco, Juan Francisco
Birmingham mid-head resection periprosthetic fractures: Case report
title Birmingham mid-head resection periprosthetic fractures: Case report
title_full Birmingham mid-head resection periprosthetic fractures: Case report
title_fullStr Birmingham mid-head resection periprosthetic fractures: Case report
title_full_unstemmed Birmingham mid-head resection periprosthetic fractures: Case report
title_short Birmingham mid-head resection periprosthetic fractures: Case report
title_sort birmingham mid-head resection periprosthetic fractures: case report
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6831797/
https://www.ncbi.nlm.nih.gov/pubmed/31669908
http://dx.doi.org/10.1016/j.ijscr.2019.10.012
work_keys_str_mv AT frailegamarraines birminghammidheadresectionperiprostheticfracturescasereport
AT jimenezviseupinheirojuanfernando birminghammidheadresectionperiprostheticfracturescasereport
AT canogalacarlos birminghammidheadresectionperiprostheticfracturescasereport
AT blancoblancojuanfrancisco birminghammidheadresectionperiprostheticfracturescasereport