Cargando…

Semi-Automatic Calibration Method for a Bed-Monitoring System Using Infrared Image Depth Sensors

With the aging of society, the number of fall accidents has increased in hospitals and care facilities, and some accidents have happened around beds. To help prevent accidents, mats and clip sensors have been used in these facilities but they can be invasive, and their purpose may be misinterpreted....

Descripción completa

Detalles Bibliográficos
Autores principales: Komagata, Hideki, Kakinuma, Erika, Ishikawa, Masahiro, Shinoda, Kazuma, Kobayashi, Naoki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832382/
https://www.ncbi.nlm.nih.gov/pubmed/31640256
http://dx.doi.org/10.3390/s19204581
_version_ 1783466158965391360
author Komagata, Hideki
Kakinuma, Erika
Ishikawa, Masahiro
Shinoda, Kazuma
Kobayashi, Naoki
author_facet Komagata, Hideki
Kakinuma, Erika
Ishikawa, Masahiro
Shinoda, Kazuma
Kobayashi, Naoki
author_sort Komagata, Hideki
collection PubMed
description With the aging of society, the number of fall accidents has increased in hospitals and care facilities, and some accidents have happened around beds. To help prevent accidents, mats and clip sensors have been used in these facilities but they can be invasive, and their purpose may be misinterpreted. In recent years, research has been conducted using an infrared-image depth sensor as a bed-monitoring system for detecting a patient getting up, exiting the bed, and/or falling; however, some manual calibration was required initially to set up the sensor in each instance. We propose a bed-monitoring system that retains the infrared-image depth sensors but uses semi-automatic rather than manual calibration in each situation where it is applied. Our automated methods robustly calculate the bed region, surrounding floor, sensor location, and attitude, and can recognize the spatial position of the patient even when the sensor is attached but unconstrained. Also, we propose a means to reconfigure the spatial position considering occlusion by parts of the bed and also accounting for the gravity center of the patient’s body. Experimental results of multi-view calibration and motion simulation showed that our methods were effective for recognition of the spatial position of the patient.
format Online
Article
Text
id pubmed-6832382
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-68323822019-11-21 Semi-Automatic Calibration Method for a Bed-Monitoring System Using Infrared Image Depth Sensors Komagata, Hideki Kakinuma, Erika Ishikawa, Masahiro Shinoda, Kazuma Kobayashi, Naoki Sensors (Basel) Article With the aging of society, the number of fall accidents has increased in hospitals and care facilities, and some accidents have happened around beds. To help prevent accidents, mats and clip sensors have been used in these facilities but they can be invasive, and their purpose may be misinterpreted. In recent years, research has been conducted using an infrared-image depth sensor as a bed-monitoring system for detecting a patient getting up, exiting the bed, and/or falling; however, some manual calibration was required initially to set up the sensor in each instance. We propose a bed-monitoring system that retains the infrared-image depth sensors but uses semi-automatic rather than manual calibration in each situation where it is applied. Our automated methods robustly calculate the bed region, surrounding floor, sensor location, and attitude, and can recognize the spatial position of the patient even when the sensor is attached but unconstrained. Also, we propose a means to reconfigure the spatial position considering occlusion by parts of the bed and also accounting for the gravity center of the patient’s body. Experimental results of multi-view calibration and motion simulation showed that our methods were effective for recognition of the spatial position of the patient. MDPI 2019-10-21 /pmc/articles/PMC6832382/ /pubmed/31640256 http://dx.doi.org/10.3390/s19204581 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Komagata, Hideki
Kakinuma, Erika
Ishikawa, Masahiro
Shinoda, Kazuma
Kobayashi, Naoki
Semi-Automatic Calibration Method for a Bed-Monitoring System Using Infrared Image Depth Sensors
title Semi-Automatic Calibration Method for a Bed-Monitoring System Using Infrared Image Depth Sensors
title_full Semi-Automatic Calibration Method for a Bed-Monitoring System Using Infrared Image Depth Sensors
title_fullStr Semi-Automatic Calibration Method for a Bed-Monitoring System Using Infrared Image Depth Sensors
title_full_unstemmed Semi-Automatic Calibration Method for a Bed-Monitoring System Using Infrared Image Depth Sensors
title_short Semi-Automatic Calibration Method for a Bed-Monitoring System Using Infrared Image Depth Sensors
title_sort semi-automatic calibration method for a bed-monitoring system using infrared image depth sensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832382/
https://www.ncbi.nlm.nih.gov/pubmed/31640256
http://dx.doi.org/10.3390/s19204581
work_keys_str_mv AT komagatahideki semiautomaticcalibrationmethodforabedmonitoringsystemusinginfraredimagedepthsensors
AT kakinumaerika semiautomaticcalibrationmethodforabedmonitoringsystemusinginfraredimagedepthsensors
AT ishikawamasahiro semiautomaticcalibrationmethodforabedmonitoringsystemusinginfraredimagedepthsensors
AT shinodakazuma semiautomaticcalibrationmethodforabedmonitoringsystemusinginfraredimagedepthsensors
AT kobayashinaoki semiautomaticcalibrationmethodforabedmonitoringsystemusinginfraredimagedepthsensors