Levels of the Thiocyanate in the Saliva of Tobacco Smokers in Comparison to e-Cigarette Smokers and Nonsmokers Measured by HPLC on a Phosphatidylcholine Column
The aim of the study was to estimate the thiocyanate levels in saliva of cigarette smokers in comparison to e-cigarette smokers and nonsmokers. To improve our understanding of the influence of smoking on the oral level of thiocyanate, we conducted an assessment of human saliva, in 24 individuals (ei...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832790/ https://www.ncbi.nlm.nih.gov/pubmed/31640293 http://dx.doi.org/10.3390/molecules24203790 |
_version_ | 1783466242831548416 |
---|---|
author | Flieger, Jolanta Kawka, Justyna Tatarczak-Michalewska, Małgorzata |
author_facet | Flieger, Jolanta Kawka, Justyna Tatarczak-Michalewska, Małgorzata |
author_sort | Flieger, Jolanta |
collection | PubMed |
description | The aim of the study was to estimate the thiocyanate levels in saliva of cigarette smokers in comparison to e-cigarette smokers and nonsmokers. To improve our understanding of the influence of smoking on the oral level of thiocyanate, we conducted an assessment of human saliva, in 24 individuals (eight tobacco smokers, eight e-cigarette smokers, and eight nonsmokers). High-Performance Liquid Chromatography with ultraviolet detection (HPLC-UV) using a unique phosphatidylcholine column was applied in this assay. Thiocyanate ion was detected directly by its absorbance at 210 nm. The method presents a new application of the IAM (Immobilized Artificial Membrane) column for quantification of inorganic anions. The whole process meets the criteria of green chemistry because it was carried out without the use of organic solvents. For compensating matrix effects, an eight-point standard addition protocol was used to quantify the thiocyanate level in saliva samples. The calibration graphs were linear in the range of 5–100 mg L(−1) with a correlation coefficient higher than 0.99. The thiocyanate concentrations in the saliva of tobacco smokers, e-cigarette smokers, and nonsmokers were found in the range of 121.25–187.54 mg L(−1), 121.24–244.11 mg L(−1), 33.03–79.49 mg L(−1), respectively. The present study indicates an obvious statistically significant elevation in salivary thiocyanate level in tobacco smokers in comparison to nonsmokers. The phosphatidylcholine-based stationary phase proved to be suitable for the detection and quantification of the thiocyanate ion. The salivary thiocyanate levels in e-cigarette smokers were not significantly different in comparison to tobacco smokers but higher if compared to nonsmokers. The criterion for statistical significance was p < 0.05. |
format | Online Article Text |
id | pubmed-6832790 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-68327902019-11-25 Levels of the Thiocyanate in the Saliva of Tobacco Smokers in Comparison to e-Cigarette Smokers and Nonsmokers Measured by HPLC on a Phosphatidylcholine Column Flieger, Jolanta Kawka, Justyna Tatarczak-Michalewska, Małgorzata Molecules Article The aim of the study was to estimate the thiocyanate levels in saliva of cigarette smokers in comparison to e-cigarette smokers and nonsmokers. To improve our understanding of the influence of smoking on the oral level of thiocyanate, we conducted an assessment of human saliva, in 24 individuals (eight tobacco smokers, eight e-cigarette smokers, and eight nonsmokers). High-Performance Liquid Chromatography with ultraviolet detection (HPLC-UV) using a unique phosphatidylcholine column was applied in this assay. Thiocyanate ion was detected directly by its absorbance at 210 nm. The method presents a new application of the IAM (Immobilized Artificial Membrane) column for quantification of inorganic anions. The whole process meets the criteria of green chemistry because it was carried out without the use of organic solvents. For compensating matrix effects, an eight-point standard addition protocol was used to quantify the thiocyanate level in saliva samples. The calibration graphs were linear in the range of 5–100 mg L(−1) with a correlation coefficient higher than 0.99. The thiocyanate concentrations in the saliva of tobacco smokers, e-cigarette smokers, and nonsmokers were found in the range of 121.25–187.54 mg L(−1), 121.24–244.11 mg L(−1), 33.03–79.49 mg L(−1), respectively. The present study indicates an obvious statistically significant elevation in salivary thiocyanate level in tobacco smokers in comparison to nonsmokers. The phosphatidylcholine-based stationary phase proved to be suitable for the detection and quantification of the thiocyanate ion. The salivary thiocyanate levels in e-cigarette smokers were not significantly different in comparison to tobacco smokers but higher if compared to nonsmokers. The criterion for statistical significance was p < 0.05. MDPI 2019-10-21 /pmc/articles/PMC6832790/ /pubmed/31640293 http://dx.doi.org/10.3390/molecules24203790 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Flieger, Jolanta Kawka, Justyna Tatarczak-Michalewska, Małgorzata Levels of the Thiocyanate in the Saliva of Tobacco Smokers in Comparison to e-Cigarette Smokers and Nonsmokers Measured by HPLC on a Phosphatidylcholine Column |
title | Levels of the Thiocyanate in the Saliva of Tobacco Smokers in Comparison to e-Cigarette Smokers and Nonsmokers Measured by HPLC on a Phosphatidylcholine Column |
title_full | Levels of the Thiocyanate in the Saliva of Tobacco Smokers in Comparison to e-Cigarette Smokers and Nonsmokers Measured by HPLC on a Phosphatidylcholine Column |
title_fullStr | Levels of the Thiocyanate in the Saliva of Tobacco Smokers in Comparison to e-Cigarette Smokers and Nonsmokers Measured by HPLC on a Phosphatidylcholine Column |
title_full_unstemmed | Levels of the Thiocyanate in the Saliva of Tobacco Smokers in Comparison to e-Cigarette Smokers and Nonsmokers Measured by HPLC on a Phosphatidylcholine Column |
title_short | Levels of the Thiocyanate in the Saliva of Tobacco Smokers in Comparison to e-Cigarette Smokers and Nonsmokers Measured by HPLC on a Phosphatidylcholine Column |
title_sort | levels of the thiocyanate in the saliva of tobacco smokers in comparison to e-cigarette smokers and nonsmokers measured by hplc on a phosphatidylcholine column |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832790/ https://www.ncbi.nlm.nih.gov/pubmed/31640293 http://dx.doi.org/10.3390/molecules24203790 |
work_keys_str_mv | AT fliegerjolanta levelsofthethiocyanateinthesalivaoftobaccosmokersincomparisontoecigarettesmokersandnonsmokersmeasuredbyhplconaphosphatidylcholinecolumn AT kawkajustyna levelsofthethiocyanateinthesalivaoftobaccosmokersincomparisontoecigarettesmokersandnonsmokersmeasuredbyhplconaphosphatidylcholinecolumn AT tatarczakmichalewskamałgorzata levelsofthethiocyanateinthesalivaoftobaccosmokersincomparisontoecigarettesmokersandnonsmokersmeasuredbyhplconaphosphatidylcholinecolumn |