Cargando…
Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of β-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry
A wooden stick coated with a novel graphene-based nanocomposite (Graphene oxide/polyethylene glycol (GO/PEG)) is introduced and investigated for its efficacy in solid phase microextraction techniques. The GO/PEG-stick was prepared and subsequently applied for the extraction of β-blockers, acebutolol...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832871/ https://www.ncbi.nlm.nih.gov/pubmed/31614604 http://dx.doi.org/10.3390/molecules24203664 |
_version_ | 1783466246637879296 |
---|---|
author | Karimiyan, Hanieh Hadjmohammadi, Mohammad Reza Kunjali, Karthik Laxman Moein, Mohammad Mahdi Dutta, Joydeep Abdel-Rehim, Mohamed |
author_facet | Karimiyan, Hanieh Hadjmohammadi, Mohammad Reza Kunjali, Karthik Laxman Moein, Mohammad Mahdi Dutta, Joydeep Abdel-Rehim, Mohamed |
author_sort | Karimiyan, Hanieh |
collection | PubMed |
description | A wooden stick coated with a novel graphene-based nanocomposite (Graphene oxide/polyethylene glycol (GO/PEG)) is introduced and investigated for its efficacy in solid phase microextraction techniques. The GO/PEG-stick was prepared and subsequently applied for the extraction of β-blockers, acebutolol, and metoprolol in human oral fluid samples, which were subsequently detected by liquid chromatography tandem mass spectrometry (LC-MS/MS). Experimental parameters affecting the extraction protocol including sample pH, extraction time, desorption time, appropriate desorption solvent, and salt addition were optimized. Method validation for the detection from oral fluid samples was performed following FDA (Food and Drug Administration) guidelines on bioanalytical method validation. Calibration curves ranging from 5.0 to 2000 nmol L(−1) for acebutolol and 25.0 to 2000 nmol L(−1) for metoprolol were used. The values for the coefficient of determination (R(2)) were found to be 0.998 and 0.996 (n = 3) for acebutolol and metoprolol, respectively. The recovery of analytes during extraction was 80.0% for acebutolol and 62.0% for metoprolol, respectively. The limit of detections (LODs) were 1.25, 8.00 nmol L(−1) for acebutolol and metoprolol and the lower limit of quantifications (LLOQ) were 5.00 nmol L(−1) for acebutolol and 25.0 nmol L(−1) for metoprolol. Validation experiments conducted with quality control (QC) samples demonstrated method accuracy between 80.0% to 97.0% for acebutolol and from 95.0% to 109.0% for metoprolol. The inter-day precision for QC samples ranged from 3.6% to 12.9% for acebutolol and 9.5% to 11.3% for metoprolol. Additionally, the GO/PEG-stick was demonstrated to be reusable, with the same stick observed to be viable for more than 10 extractions from oral fluid samples. |
format | Online Article Text |
id | pubmed-6832871 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-68328712019-11-25 Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of β-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry Karimiyan, Hanieh Hadjmohammadi, Mohammad Reza Kunjali, Karthik Laxman Moein, Mohammad Mahdi Dutta, Joydeep Abdel-Rehim, Mohamed Molecules Article A wooden stick coated with a novel graphene-based nanocomposite (Graphene oxide/polyethylene glycol (GO/PEG)) is introduced and investigated for its efficacy in solid phase microextraction techniques. The GO/PEG-stick was prepared and subsequently applied for the extraction of β-blockers, acebutolol, and metoprolol in human oral fluid samples, which were subsequently detected by liquid chromatography tandem mass spectrometry (LC-MS/MS). Experimental parameters affecting the extraction protocol including sample pH, extraction time, desorption time, appropriate desorption solvent, and salt addition were optimized. Method validation for the detection from oral fluid samples was performed following FDA (Food and Drug Administration) guidelines on bioanalytical method validation. Calibration curves ranging from 5.0 to 2000 nmol L(−1) for acebutolol and 25.0 to 2000 nmol L(−1) for metoprolol were used. The values for the coefficient of determination (R(2)) were found to be 0.998 and 0.996 (n = 3) for acebutolol and metoprolol, respectively. The recovery of analytes during extraction was 80.0% for acebutolol and 62.0% for metoprolol, respectively. The limit of detections (LODs) were 1.25, 8.00 nmol L(−1) for acebutolol and metoprolol and the lower limit of quantifications (LLOQ) were 5.00 nmol L(−1) for acebutolol and 25.0 nmol L(−1) for metoprolol. Validation experiments conducted with quality control (QC) samples demonstrated method accuracy between 80.0% to 97.0% for acebutolol and from 95.0% to 109.0% for metoprolol. The inter-day precision for QC samples ranged from 3.6% to 12.9% for acebutolol and 9.5% to 11.3% for metoprolol. Additionally, the GO/PEG-stick was demonstrated to be reusable, with the same stick observed to be viable for more than 10 extractions from oral fluid samples. MDPI 2019-10-11 /pmc/articles/PMC6832871/ /pubmed/31614604 http://dx.doi.org/10.3390/molecules24203664 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Karimiyan, Hanieh Hadjmohammadi, Mohammad Reza Kunjali, Karthik Laxman Moein, Mohammad Mahdi Dutta, Joydeep Abdel-Rehim, Mohamed Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of β-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry |
title | Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of β-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry |
title_full | Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of β-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry |
title_fullStr | Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of β-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry |
title_full_unstemmed | Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of β-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry |
title_short | Graphene Oxide/Polyethylene Glycol-Stick for Thin Film Microextraction of β-Blockers from Human Oral Fluid by Liquid Chromatography-Tandem Mass Spectrometry |
title_sort | graphene oxide/polyethylene glycol-stick for thin film microextraction of β-blockers from human oral fluid by liquid chromatography-tandem mass spectrometry |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832871/ https://www.ncbi.nlm.nih.gov/pubmed/31614604 http://dx.doi.org/10.3390/molecules24203664 |
work_keys_str_mv | AT karimiyanhanieh grapheneoxidepolyethyleneglycolstickforthinfilmmicroextractionofbblockersfromhumanoralfluidbyliquidchromatographytandemmassspectrometry AT hadjmohammadimohammadreza grapheneoxidepolyethyleneglycolstickforthinfilmmicroextractionofbblockersfromhumanoralfluidbyliquidchromatographytandemmassspectrometry AT kunjalikarthiklaxman grapheneoxidepolyethyleneglycolstickforthinfilmmicroextractionofbblockersfromhumanoralfluidbyliquidchromatographytandemmassspectrometry AT moeinmohammadmahdi grapheneoxidepolyethyleneglycolstickforthinfilmmicroextractionofbblockersfromhumanoralfluidbyliquidchromatographytandemmassspectrometry AT duttajoydeep grapheneoxidepolyethyleneglycolstickforthinfilmmicroextractionofbblockersfromhumanoralfluidbyliquidchromatographytandemmassspectrometry AT abdelrehimmohamed grapheneoxidepolyethyleneglycolstickforthinfilmmicroextractionofbblockersfromhumanoralfluidbyliquidchromatographytandemmassspectrometry |