Cargando…

A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer

The present work experimentally demonstrates a multimode fiber optic sensing setup for total fat detection in raw milk samples. The optical fiber arrangement incorporates a low-coherence Fabry–Perot cavity operating in dual response. The system provides a phase modulation for a total fat range from...

Descripción completa

Detalles Bibliográficos
Autores principales: Gastélum-Barrios, Abraham, Soto-Zarazúa, Genaro M., García-Trejo, Juan F., Sierra-Hernandez, Juan M., Jauregui-Vazquez, Daniel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832894/
https://www.ncbi.nlm.nih.gov/pubmed/31635201
http://dx.doi.org/10.3390/s19204562
_version_ 1783466250393878528
author Gastélum-Barrios, Abraham
Soto-Zarazúa, Genaro M.
García-Trejo, Juan F.
Sierra-Hernandez, Juan M.
Jauregui-Vazquez, Daniel
author_facet Gastélum-Barrios, Abraham
Soto-Zarazúa, Genaro M.
García-Trejo, Juan F.
Sierra-Hernandez, Juan M.
Jauregui-Vazquez, Daniel
author_sort Gastélum-Barrios, Abraham
collection PubMed
description The present work experimentally demonstrates a multimode fiber optic sensing setup for total fat detection in raw milk samples. The optical fiber arrangement incorporates a low-coherence Fabry–Perot cavity operating in dual response. The system provides a phase modulation for a total fat range from 0.97 to 4.36%. Here, the protein remains constant at ≈3%. The data indicate that maximum sensitivity close to 616 pm/%fat could be achieved at optimal wavelength operation (500 nm). In addition, the system presented a minimal repeatability error measurement of 0.08%, cross-sensitivity between protein and fat of 0.134, and a regression coefficient of [Formula: see text]. A thermal analysis was also performed, which indicate the temperature immunity of the system. The proposed method represents a low-cost alternative to detect minimal fat variations in raw cow milk.
format Online
Article
Text
id pubmed-6832894
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-68328942019-11-25 A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer Gastélum-Barrios, Abraham Soto-Zarazúa, Genaro M. García-Trejo, Juan F. Sierra-Hernandez, Juan M. Jauregui-Vazquez, Daniel Sensors (Basel) Article The present work experimentally demonstrates a multimode fiber optic sensing setup for total fat detection in raw milk samples. The optical fiber arrangement incorporates a low-coherence Fabry–Perot cavity operating in dual response. The system provides a phase modulation for a total fat range from 0.97 to 4.36%. Here, the protein remains constant at ≈3%. The data indicate that maximum sensitivity close to 616 pm/%fat could be achieved at optimal wavelength operation (500 nm). In addition, the system presented a minimal repeatability error measurement of 0.08%, cross-sensitivity between protein and fat of 0.134, and a regression coefficient of [Formula: see text]. A thermal analysis was also performed, which indicate the temperature immunity of the system. The proposed method represents a low-cost alternative to detect minimal fat variations in raw cow milk. MDPI 2019-10-20 /pmc/articles/PMC6832894/ /pubmed/31635201 http://dx.doi.org/10.3390/s19204562 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gastélum-Barrios, Abraham
Soto-Zarazúa, Genaro M.
García-Trejo, Juan F.
Sierra-Hernandez, Juan M.
Jauregui-Vazquez, Daniel
A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer
title A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer
title_full A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer
title_fullStr A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer
title_full_unstemmed A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer
title_short A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer
title_sort new method for total fat detection in raw milk based on dual low-coherence interferometer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832894/
https://www.ncbi.nlm.nih.gov/pubmed/31635201
http://dx.doi.org/10.3390/s19204562
work_keys_str_mv AT gastelumbarriosabraham anewmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer
AT sotozarazuagenarom anewmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer
AT garciatrejojuanf anewmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer
AT sierrahernandezjuanm anewmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer
AT jaureguivazquezdaniel anewmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer
AT gastelumbarriosabraham newmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer
AT sotozarazuagenarom newmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer
AT garciatrejojuanf newmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer
AT sierrahernandezjuanm newmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer
AT jaureguivazquezdaniel newmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer