A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer
The present work experimentally demonstrates a multimode fiber optic sensing setup for total fat detection in raw milk samples. The optical fiber arrangement incorporates a low-coherence Fabry–Perot cavity operating in dual response. The system provides a phase modulation for a total fat range from...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832894/ https://www.ncbi.nlm.nih.gov/pubmed/31635201 http://dx.doi.org/10.3390/s19204562 |
_version_ | 1783466250393878528 |
---|---|
author | Gastélum-Barrios, Abraham Soto-Zarazúa, Genaro M. García-Trejo, Juan F. Sierra-Hernandez, Juan M. Jauregui-Vazquez, Daniel |
author_facet | Gastélum-Barrios, Abraham Soto-Zarazúa, Genaro M. García-Trejo, Juan F. Sierra-Hernandez, Juan M. Jauregui-Vazquez, Daniel |
author_sort | Gastélum-Barrios, Abraham |
collection | PubMed |
description | The present work experimentally demonstrates a multimode fiber optic sensing setup for total fat detection in raw milk samples. The optical fiber arrangement incorporates a low-coherence Fabry–Perot cavity operating in dual response. The system provides a phase modulation for a total fat range from 0.97 to 4.36%. Here, the protein remains constant at ≈3%. The data indicate that maximum sensitivity close to 616 pm/%fat could be achieved at optimal wavelength operation (500 nm). In addition, the system presented a minimal repeatability error measurement of 0.08%, cross-sensitivity between protein and fat of 0.134, and a regression coefficient of [Formula: see text]. A thermal analysis was also performed, which indicate the temperature immunity of the system. The proposed method represents a low-cost alternative to detect minimal fat variations in raw cow milk. |
format | Online Article Text |
id | pubmed-6832894 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-68328942019-11-25 A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer Gastélum-Barrios, Abraham Soto-Zarazúa, Genaro M. García-Trejo, Juan F. Sierra-Hernandez, Juan M. Jauregui-Vazquez, Daniel Sensors (Basel) Article The present work experimentally demonstrates a multimode fiber optic sensing setup for total fat detection in raw milk samples. The optical fiber arrangement incorporates a low-coherence Fabry–Perot cavity operating in dual response. The system provides a phase modulation for a total fat range from 0.97 to 4.36%. Here, the protein remains constant at ≈3%. The data indicate that maximum sensitivity close to 616 pm/%fat could be achieved at optimal wavelength operation (500 nm). In addition, the system presented a minimal repeatability error measurement of 0.08%, cross-sensitivity between protein and fat of 0.134, and a regression coefficient of [Formula: see text]. A thermal analysis was also performed, which indicate the temperature immunity of the system. The proposed method represents a low-cost alternative to detect minimal fat variations in raw cow milk. MDPI 2019-10-20 /pmc/articles/PMC6832894/ /pubmed/31635201 http://dx.doi.org/10.3390/s19204562 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Gastélum-Barrios, Abraham Soto-Zarazúa, Genaro M. García-Trejo, Juan F. Sierra-Hernandez, Juan M. Jauregui-Vazquez, Daniel A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer |
title | A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer |
title_full | A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer |
title_fullStr | A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer |
title_full_unstemmed | A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer |
title_short | A New Method for Total Fat Detection in Raw Milk Based on Dual Low-Coherence Interferometer |
title_sort | new method for total fat detection in raw milk based on dual low-coherence interferometer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832894/ https://www.ncbi.nlm.nih.gov/pubmed/31635201 http://dx.doi.org/10.3390/s19204562 |
work_keys_str_mv | AT gastelumbarriosabraham anewmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer AT sotozarazuagenarom anewmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer AT garciatrejojuanf anewmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer AT sierrahernandezjuanm anewmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer AT jaureguivazquezdaniel anewmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer AT gastelumbarriosabraham newmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer AT sotozarazuagenarom newmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer AT garciatrejojuanf newmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer AT sierrahernandezjuanm newmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer AT jaureguivazquezdaniel newmethodfortotalfatdetectioninrawmilkbasedonduallowcoherenceinterferometer |