Parylene-Coated Polytetrafluoroethylene-Membrane-Based Portable Urea Sensor for Real-Time Monitoring of Urea in Peritoneal Dialysate

A portable urea sensor for use in fast flow conditions was fabricated using porous polytetrafluoroethylene (PTFE) membranes coated with amine-functionalized parylene, parylene-A, by vapor deposition. The urea-hydrolyzing enzyme urease was immobilized on the parylene-A-coated PTFE membranes using glu...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Min, Kim, JeeYoung, Kim, Kyounghee, Pyun, Jae-Chul, Sung, Gun Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832945/
https://www.ncbi.nlm.nih.gov/pubmed/31635189
http://dx.doi.org/10.3390/s19204560
_version_ 1783466263062773760
author Park, Min
Kim, JeeYoung
Kim, Kyounghee
Pyun, Jae-Chul
Sung, Gun Yong
author_facet Park, Min
Kim, JeeYoung
Kim, Kyounghee
Pyun, Jae-Chul
Sung, Gun Yong
author_sort Park, Min
collection PubMed
description A portable urea sensor for use in fast flow conditions was fabricated using porous polytetrafluoroethylene (PTFE) membranes coated with amine-functionalized parylene, parylene-A, by vapor deposition. The urea-hydrolyzing enzyme urease was immobilized on the parylene-A-coated PTFE membranes using glutaraldehyde. The urease-immobilized membranes were assembled in a polydimethylsiloxane (PDMS) fluidic chamber, and a screen-printed carbon three-electrode system was used for electrochemical measurements. The success of urease immobilization was confirmed using scanning electron microscopy, and fourier-transform infrared spectroscopy. The optimum concentration of urease for immobilization on the parylene-A-coated PTFE membranes was determined to be 48 mg/mL, and the optimum number of membranes in the PDMS chamber was found to be eight. Using these optimized conditions, we fabricated the urea biosensor and monitored urea samples under various flow rates ranging from 0.5 to 10 mL/min in the flow condition using chronoamperometry. To test the applicability of the sensor for physiological samples, we used it for monitoring urea concentration in the waste peritoneal dialysate of a patient with chronic renal failure, at a flow rate of 0.5 mL/min. This developed urea biosensor is considered applicable for (portable) applications, such as artificial kidney systems and portable dialysis systems.
format Online
Article
Text
id pubmed-6832945
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-68329452019-11-25 Parylene-Coated Polytetrafluoroethylene-Membrane-Based Portable Urea Sensor for Real-Time Monitoring of Urea in Peritoneal Dialysate Park, Min Kim, JeeYoung Kim, Kyounghee Pyun, Jae-Chul Sung, Gun Yong Sensors (Basel) Article A portable urea sensor for use in fast flow conditions was fabricated using porous polytetrafluoroethylene (PTFE) membranes coated with amine-functionalized parylene, parylene-A, by vapor deposition. The urea-hydrolyzing enzyme urease was immobilized on the parylene-A-coated PTFE membranes using glutaraldehyde. The urease-immobilized membranes were assembled in a polydimethylsiloxane (PDMS) fluidic chamber, and a screen-printed carbon three-electrode system was used for electrochemical measurements. The success of urease immobilization was confirmed using scanning electron microscopy, and fourier-transform infrared spectroscopy. The optimum concentration of urease for immobilization on the parylene-A-coated PTFE membranes was determined to be 48 mg/mL, and the optimum number of membranes in the PDMS chamber was found to be eight. Using these optimized conditions, we fabricated the urea biosensor and monitored urea samples under various flow rates ranging from 0.5 to 10 mL/min in the flow condition using chronoamperometry. To test the applicability of the sensor for physiological samples, we used it for monitoring urea concentration in the waste peritoneal dialysate of a patient with chronic renal failure, at a flow rate of 0.5 mL/min. This developed urea biosensor is considered applicable for (portable) applications, such as artificial kidney systems and portable dialysis systems. MDPI 2019-10-20 /pmc/articles/PMC6832945/ /pubmed/31635189 http://dx.doi.org/10.3390/s19204560 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Park, Min
Kim, JeeYoung
Kim, Kyounghee
Pyun, Jae-Chul
Sung, Gun Yong
Parylene-Coated Polytetrafluoroethylene-Membrane-Based Portable Urea Sensor for Real-Time Monitoring of Urea in Peritoneal Dialysate
title Parylene-Coated Polytetrafluoroethylene-Membrane-Based Portable Urea Sensor for Real-Time Monitoring of Urea in Peritoneal Dialysate
title_full Parylene-Coated Polytetrafluoroethylene-Membrane-Based Portable Urea Sensor for Real-Time Monitoring of Urea in Peritoneal Dialysate
title_fullStr Parylene-Coated Polytetrafluoroethylene-Membrane-Based Portable Urea Sensor for Real-Time Monitoring of Urea in Peritoneal Dialysate
title_full_unstemmed Parylene-Coated Polytetrafluoroethylene-Membrane-Based Portable Urea Sensor for Real-Time Monitoring of Urea in Peritoneal Dialysate
title_short Parylene-Coated Polytetrafluoroethylene-Membrane-Based Portable Urea Sensor for Real-Time Monitoring of Urea in Peritoneal Dialysate
title_sort parylene-coated polytetrafluoroethylene-membrane-based portable urea sensor for real-time monitoring of urea in peritoneal dialysate
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6832945/
https://www.ncbi.nlm.nih.gov/pubmed/31635189
http://dx.doi.org/10.3390/s19204560
work_keys_str_mv AT parkmin parylenecoatedpolytetrafluoroethylenemembranebasedportableureasensorforrealtimemonitoringofureainperitonealdialysate
AT kimjeeyoung parylenecoatedpolytetrafluoroethylenemembranebasedportableureasensorforrealtimemonitoringofureainperitonealdialysate
AT kimkyounghee parylenecoatedpolytetrafluoroethylenemembranebasedportableureasensorforrealtimemonitoringofureainperitonealdialysate
AT pyunjaechul parylenecoatedpolytetrafluoroethylenemembranebasedportableureasensorforrealtimemonitoringofureainperitonealdialysate
AT sunggunyong parylenecoatedpolytetrafluoroethylenemembranebasedportableureasensorforrealtimemonitoringofureainperitonealdialysate