Cargando…

Factors Related to Successful Energy Transmission of Focused Ultrasound through a Skull : A Study in Human Cadavers and Its Comparison with Clinical Experiences

OBJECTIVE: Although magnetic resonance guided focused ultrasound (MRgFUS) has been used as minimally invasive and effective neurosurgical treatment, it exhibits some limitations, mainly related to acoustic properties of the skull barrier. This study was undertaken to identify skull characteristics t...

Descripción completa

Detalles Bibliográficos
Autores principales: Jung, Na Young, Rachmilevitch, Itay, Sibiger, Ohad, Amar, Talia, Zadicario, Eyal, Chang, Jin Woo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Neurosurgical Society 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6835146/
https://www.ncbi.nlm.nih.gov/pubmed/31142101
http://dx.doi.org/10.3340/jkns.2018.0226
_version_ 1783466598470778880
author Jung, Na Young
Rachmilevitch, Itay
Sibiger, Ohad
Amar, Talia
Zadicario, Eyal
Chang, Jin Woo
author_facet Jung, Na Young
Rachmilevitch, Itay
Sibiger, Ohad
Amar, Talia
Zadicario, Eyal
Chang, Jin Woo
author_sort Jung, Na Young
collection PubMed
description OBJECTIVE: Although magnetic resonance guided focused ultrasound (MRgFUS) has been used as minimally invasive and effective neurosurgical treatment, it exhibits some limitations, mainly related to acoustic properties of the skull barrier. This study was undertaken to identify skull characteristics that contribute to optimal ultrasonic energy transmission for MRgFUS procedures. METHODS: For ex vivo skull experiments, various acoustic fields were measured under different conditions, using five non-embalmed cadaver skulls. For clinical skull analyses, brain computed tomography data of 46 patients who underwent MRgFUS ablations (18 unilateral thalamotomy, nine unilateral pallidotomy, and 19 bilateral capsulotomy) were retrospectively reviewed. Patients' skull factors and sonication parameters were comparatively analyzed with respect to the cadaveric skulls. RESULTS: Skull experiments identified three important factors related skull penetration of ultrasound, including skull density ratio (SDR), skull volume, and incidence angle of the acoustic rays against the skull surface. In clinical results, SDR and skull volume correlated with maximal temperature (Tmax) and energy requirement to achieve Tmax (p<0.05). In addition, considering the incidence angle determined by brain target location, less energy was required to reach Tmax in the central, rather than lateral targets particularly when compared between thalamotomy and capsulotomy (p<0.05). CONCLUSION: This study reconfirmed previously identified skull factors, including SDR and skull volume, for successful MRgFUS; it identified an additional factor, incidence angle of acoustic rays against the skull surface. To guarantee successful transcranial MRgFUS treatment without suffering these various skull issues, further technical improvements are required.
format Online
Article
Text
id pubmed-6835146
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Korean Neurosurgical Society
record_format MEDLINE/PubMed
spelling pubmed-68351462019-11-13 Factors Related to Successful Energy Transmission of Focused Ultrasound through a Skull : A Study in Human Cadavers and Its Comparison with Clinical Experiences Jung, Na Young Rachmilevitch, Itay Sibiger, Ohad Amar, Talia Zadicario, Eyal Chang, Jin Woo J Korean Neurosurg Soc Clinical Article OBJECTIVE: Although magnetic resonance guided focused ultrasound (MRgFUS) has been used as minimally invasive and effective neurosurgical treatment, it exhibits some limitations, mainly related to acoustic properties of the skull barrier. This study was undertaken to identify skull characteristics that contribute to optimal ultrasonic energy transmission for MRgFUS procedures. METHODS: For ex vivo skull experiments, various acoustic fields were measured under different conditions, using five non-embalmed cadaver skulls. For clinical skull analyses, brain computed tomography data of 46 patients who underwent MRgFUS ablations (18 unilateral thalamotomy, nine unilateral pallidotomy, and 19 bilateral capsulotomy) were retrospectively reviewed. Patients' skull factors and sonication parameters were comparatively analyzed with respect to the cadaveric skulls. RESULTS: Skull experiments identified three important factors related skull penetration of ultrasound, including skull density ratio (SDR), skull volume, and incidence angle of the acoustic rays against the skull surface. In clinical results, SDR and skull volume correlated with maximal temperature (Tmax) and energy requirement to achieve Tmax (p<0.05). In addition, considering the incidence angle determined by brain target location, less energy was required to reach Tmax in the central, rather than lateral targets particularly when compared between thalamotomy and capsulotomy (p<0.05). CONCLUSION: This study reconfirmed previously identified skull factors, including SDR and skull volume, for successful MRgFUS; it identified an additional factor, incidence angle of acoustic rays against the skull surface. To guarantee successful transcranial MRgFUS treatment without suffering these various skull issues, further technical improvements are required. Korean Neurosurgical Society 2019-11 2019-05-30 /pmc/articles/PMC6835146/ /pubmed/31142101 http://dx.doi.org/10.3340/jkns.2018.0226 Text en Copyright © 2019 The Korean Neurosurgical Society This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Article
Jung, Na Young
Rachmilevitch, Itay
Sibiger, Ohad
Amar, Talia
Zadicario, Eyal
Chang, Jin Woo
Factors Related to Successful Energy Transmission of Focused Ultrasound through a Skull : A Study in Human Cadavers and Its Comparison with Clinical Experiences
title Factors Related to Successful Energy Transmission of Focused Ultrasound through a Skull : A Study in Human Cadavers and Its Comparison with Clinical Experiences
title_full Factors Related to Successful Energy Transmission of Focused Ultrasound through a Skull : A Study in Human Cadavers and Its Comparison with Clinical Experiences
title_fullStr Factors Related to Successful Energy Transmission of Focused Ultrasound through a Skull : A Study in Human Cadavers and Its Comparison with Clinical Experiences
title_full_unstemmed Factors Related to Successful Energy Transmission of Focused Ultrasound through a Skull : A Study in Human Cadavers and Its Comparison with Clinical Experiences
title_short Factors Related to Successful Energy Transmission of Focused Ultrasound through a Skull : A Study in Human Cadavers and Its Comparison with Clinical Experiences
title_sort factors related to successful energy transmission of focused ultrasound through a skull : a study in human cadavers and its comparison with clinical experiences
topic Clinical Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6835146/
https://www.ncbi.nlm.nih.gov/pubmed/31142101
http://dx.doi.org/10.3340/jkns.2018.0226
work_keys_str_mv AT jungnayoung factorsrelatedtosuccessfulenergytransmissionoffocusedultrasoundthroughaskullastudyinhumancadaversanditscomparisonwithclinicalexperiences
AT rachmilevitchitay factorsrelatedtosuccessfulenergytransmissionoffocusedultrasoundthroughaskullastudyinhumancadaversanditscomparisonwithclinicalexperiences
AT sibigerohad factorsrelatedtosuccessfulenergytransmissionoffocusedultrasoundthroughaskullastudyinhumancadaversanditscomparisonwithclinicalexperiences
AT amartalia factorsrelatedtosuccessfulenergytransmissionoffocusedultrasoundthroughaskullastudyinhumancadaversanditscomparisonwithclinicalexperiences
AT zadicarioeyal factorsrelatedtosuccessfulenergytransmissionoffocusedultrasoundthroughaskullastudyinhumancadaversanditscomparisonwithclinicalexperiences
AT changjinwoo factorsrelatedtosuccessfulenergytransmissionoffocusedultrasoundthroughaskullastudyinhumancadaversanditscomparisonwithclinicalexperiences