Cargando…
Breast Imaging Reporting and Data Systems category 3 (probably benign) breast lesions detected on diagnostic breast ultrasound: The prevalence, outcome and malignancy detection rate in Zaria, Nigeria
BACKGROUND: Probably benign breast lesions in the Breast Imaging Reporting and Data Systems (BI-RADS 3) constitute a crucial category and a considerable number of all palpable breast masses. Local data concerning the outcome of such lesions in the Nigerian environment is almost non-existent. OBJECTI...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AOSIS
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6837800/ https://www.ncbi.nlm.nih.gov/pubmed/31754512 http://dx.doi.org/10.4102/sajr.v22i2.1315 |
_version_ | 1783467112690352128 |
---|---|
author | Olarinoye-Akorede, Sefiya A. Yunusa, Garba H. Aliyu, Halima Hamidu, Ahmed U. |
author_facet | Olarinoye-Akorede, Sefiya A. Yunusa, Garba H. Aliyu, Halima Hamidu, Ahmed U. |
author_sort | Olarinoye-Akorede, Sefiya A. |
collection | PubMed |
description | BACKGROUND: Probably benign breast lesions in the Breast Imaging Reporting and Data Systems (BI-RADS 3) constitute a crucial category and a considerable number of all palpable breast masses. Local data concerning the outcome of such lesions in the Nigerian environment is almost non-existent. OBJECTIVES: The goal of this article is to report the frequency, outcome and malignancy detection rate among palpable breast masses that were categorised on ultrasound as BI-RADS category 3 (probably benign) according to the American College of Radiology (ACR). METHODS: Between January 2015 and July 2017, 603 patients had diagnostic whole-breast ultrasound scans. There were 277 women who complained of palpable breast masses, of whom 151 women were diagnosed as having BI-RADS 3 lesions. The final lesion outcome was determined by either biopsy or ultrasound follow-up examination for a total of 2 years. All data were recorded and analysed with Statistical Package for the Social Sciences (SPSS) version 20 (Chicago, USA). RESULTS: The frequency of BI-RADS category 3 lesions among all the women who underwent breast ultrasound was 25% (151/603); and 54% (151/277) in patients with palpable breast masses. There were 25 patients who were excluded because of incomplete data or who were lost to follow-up. A total of 122 patients had both ultrasound examination and histopathologic diagnosis, while only 4 were followed up for 2 years on ultrasound alone. Of the 122 women biopsied, 117 (95.9%) had benign histologic outcomes, and of the remaining 5, cancer was confirmed in 2 (1.6%), while the remaining 3 patients (2.5%) had lesions considered intermediate at histology (juvenile papillomatosis, borderline phylloides and atypical ductal hyperplasia). Three out of four patients who had ultrasound follow-up alone had stable lesions after 2 years, while one patient had complete resolution. CONCLUSION: This study found a significantly high biopsy rate of 80% (122/151) for probably benign lesions but a low detection rate for malignancy (1.6%). Follow-up with imaging rather than biopsy for lesions sonographically described as probably benign, will reduce medical costs and unwarranted invasive procedures. |
format | Online Article Text |
id | pubmed-6837800 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | AOSIS |
record_format | MEDLINE/PubMed |
spelling | pubmed-68378002019-11-21 Breast Imaging Reporting and Data Systems category 3 (probably benign) breast lesions detected on diagnostic breast ultrasound: The prevalence, outcome and malignancy detection rate in Zaria, Nigeria Olarinoye-Akorede, Sefiya A. Yunusa, Garba H. Aliyu, Halima Hamidu, Ahmed U. SA J Radiol Original Research BACKGROUND: Probably benign breast lesions in the Breast Imaging Reporting and Data Systems (BI-RADS 3) constitute a crucial category and a considerable number of all palpable breast masses. Local data concerning the outcome of such lesions in the Nigerian environment is almost non-existent. OBJECTIVES: The goal of this article is to report the frequency, outcome and malignancy detection rate among palpable breast masses that were categorised on ultrasound as BI-RADS category 3 (probably benign) according to the American College of Radiology (ACR). METHODS: Between January 2015 and July 2017, 603 patients had diagnostic whole-breast ultrasound scans. There were 277 women who complained of palpable breast masses, of whom 151 women were diagnosed as having BI-RADS 3 lesions. The final lesion outcome was determined by either biopsy or ultrasound follow-up examination for a total of 2 years. All data were recorded and analysed with Statistical Package for the Social Sciences (SPSS) version 20 (Chicago, USA). RESULTS: The frequency of BI-RADS category 3 lesions among all the women who underwent breast ultrasound was 25% (151/603); and 54% (151/277) in patients with palpable breast masses. There were 25 patients who were excluded because of incomplete data or who were lost to follow-up. A total of 122 patients had both ultrasound examination and histopathologic diagnosis, while only 4 were followed up for 2 years on ultrasound alone. Of the 122 women biopsied, 117 (95.9%) had benign histologic outcomes, and of the remaining 5, cancer was confirmed in 2 (1.6%), while the remaining 3 patients (2.5%) had lesions considered intermediate at histology (juvenile papillomatosis, borderline phylloides and atypical ductal hyperplasia). Three out of four patients who had ultrasound follow-up alone had stable lesions after 2 years, while one patient had complete resolution. CONCLUSION: This study found a significantly high biopsy rate of 80% (122/151) for probably benign lesions but a low detection rate for malignancy (1.6%). Follow-up with imaging rather than biopsy for lesions sonographically described as probably benign, will reduce medical costs and unwarranted invasive procedures. AOSIS 2018-11-01 /pmc/articles/PMC6837800/ /pubmed/31754512 http://dx.doi.org/10.4102/sajr.v22i2.1315 Text en © 2018. The Authors https://creativecommons.org/licenses/by/4.0/ Licensee: AOSIS. This work is licensed under the Creative Commons Attribution License. |
spellingShingle | Original Research Olarinoye-Akorede, Sefiya A. Yunusa, Garba H. Aliyu, Halima Hamidu, Ahmed U. Breast Imaging Reporting and Data Systems category 3 (probably benign) breast lesions detected on diagnostic breast ultrasound: The prevalence, outcome and malignancy detection rate in Zaria, Nigeria |
title | Breast Imaging Reporting and Data Systems category 3 (probably benign) breast lesions detected on diagnostic breast ultrasound: The prevalence, outcome and malignancy detection rate in Zaria, Nigeria |
title_full | Breast Imaging Reporting and Data Systems category 3 (probably benign) breast lesions detected on diagnostic breast ultrasound: The prevalence, outcome and malignancy detection rate in Zaria, Nigeria |
title_fullStr | Breast Imaging Reporting and Data Systems category 3 (probably benign) breast lesions detected on diagnostic breast ultrasound: The prevalence, outcome and malignancy detection rate in Zaria, Nigeria |
title_full_unstemmed | Breast Imaging Reporting and Data Systems category 3 (probably benign) breast lesions detected on diagnostic breast ultrasound: The prevalence, outcome and malignancy detection rate in Zaria, Nigeria |
title_short | Breast Imaging Reporting and Data Systems category 3 (probably benign) breast lesions detected on diagnostic breast ultrasound: The prevalence, outcome and malignancy detection rate in Zaria, Nigeria |
title_sort | breast imaging reporting and data systems category 3 (probably benign) breast lesions detected on diagnostic breast ultrasound: the prevalence, outcome and malignancy detection rate in zaria, nigeria |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6837800/ https://www.ncbi.nlm.nih.gov/pubmed/31754512 http://dx.doi.org/10.4102/sajr.v22i2.1315 |
work_keys_str_mv | AT olarinoyeakoredesefiyaa breastimagingreportinganddatasystemscategory3probablybenignbreastlesionsdetectedondiagnosticbreastultrasoundtheprevalenceoutcomeandmalignancydetectionrateinzarianigeria AT yunusagarbah breastimagingreportinganddatasystemscategory3probablybenignbreastlesionsdetectedondiagnosticbreastultrasoundtheprevalenceoutcomeandmalignancydetectionrateinzarianigeria AT aliyuhalima breastimagingreportinganddatasystemscategory3probablybenignbreastlesionsdetectedondiagnosticbreastultrasoundtheprevalenceoutcomeandmalignancydetectionrateinzarianigeria AT hamiduahmedu breastimagingreportinganddatasystemscategory3probablybenignbreastlesionsdetectedondiagnosticbreastultrasoundtheprevalenceoutcomeandmalignancydetectionrateinzarianigeria |