Cargando…

Multi-residue ultra-performance liquid chromatography coupled with tandem mass spectrometry method for comprehensive multi-class anthropogenic compounds of emerging concern analysis in a catchment-based exposure-driven study

This paper presents a new multi-residue method for the quantification of more than 142 anthropogenic compounds of emerging concern (CECs) in various environmental matrices. These CECs are from a wide range of major classes including pharmaceuticals, household, industrial and agricultural. This metho...

Descripción completa

Detalles Bibliográficos
Autores principales: Proctor, Kathryn, Petrie, Bruce, Barden, Ruth, Arnot, Tom, Kasprzyk-Hordern, Barbara
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6838033/
https://www.ncbi.nlm.nih.gov/pubmed/31494686
http://dx.doi.org/10.1007/s00216-019-02091-8
_version_ 1783467140523753472
author Proctor, Kathryn
Petrie, Bruce
Barden, Ruth
Arnot, Tom
Kasprzyk-Hordern, Barbara
author_facet Proctor, Kathryn
Petrie, Bruce
Barden, Ruth
Arnot, Tom
Kasprzyk-Hordern, Barbara
author_sort Proctor, Kathryn
collection PubMed
description This paper presents a new multi-residue method for the quantification of more than 142 anthropogenic compounds of emerging concern (CECs) in various environmental matrices. These CECs are from a wide range of major classes including pharmaceuticals, household, industrial and agricultural. This method utilises ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) for analysis of five matrices (three liquid and two solid) from wastewater treatment processes and the surrounding environment. Relative recoveries were predominantly between 80 and 120%; however, due to the complexity of the matrices used in this work, not all compounds were recovered in all matrices, from 138/142 analytes in surface water to 96/142 analytes in digested solids. Method quantification limits (MQLs) ranged from 0.004 ng L(−1) (bisoprolol in surface water) to 3118 ng L(−1) (creatinine in wastewater treatment work (WwTW) influent). The overall method accuracy was 107.0%, and precision was 13.4%. To test its performance, the method was applied to the range of environmental matrices at WwTWs in South West England. Overall, this method was found to be suitable for application in catchment-based exposure-driven studies, as, of the total number of analytes quantifiable in each matrix, 61% on average was found to be above their corresponding MQL. The results confirm the need for analysing both the liquid and solid compartments within a WwTW to prevent under-reporting of concentrations. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00216-019-02091-8) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6838033
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-68380332019-11-20 Multi-residue ultra-performance liquid chromatography coupled with tandem mass spectrometry method for comprehensive multi-class anthropogenic compounds of emerging concern analysis in a catchment-based exposure-driven study Proctor, Kathryn Petrie, Bruce Barden, Ruth Arnot, Tom Kasprzyk-Hordern, Barbara Anal Bioanal Chem Paper in Forefront This paper presents a new multi-residue method for the quantification of more than 142 anthropogenic compounds of emerging concern (CECs) in various environmental matrices. These CECs are from a wide range of major classes including pharmaceuticals, household, industrial and agricultural. This method utilises ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) for analysis of five matrices (three liquid and two solid) from wastewater treatment processes and the surrounding environment. Relative recoveries were predominantly between 80 and 120%; however, due to the complexity of the matrices used in this work, not all compounds were recovered in all matrices, from 138/142 analytes in surface water to 96/142 analytes in digested solids. Method quantification limits (MQLs) ranged from 0.004 ng L(−1) (bisoprolol in surface water) to 3118 ng L(−1) (creatinine in wastewater treatment work (WwTW) influent). The overall method accuracy was 107.0%, and precision was 13.4%. To test its performance, the method was applied to the range of environmental matrices at WwTWs in South West England. Overall, this method was found to be suitable for application in catchment-based exposure-driven studies, as, of the total number of analytes quantifiable in each matrix, 61% on average was found to be above their corresponding MQL. The results confirm the need for analysing both the liquid and solid compartments within a WwTW to prevent under-reporting of concentrations. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00216-019-02091-8) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2019-09-07 2019 /pmc/articles/PMC6838033/ /pubmed/31494686 http://dx.doi.org/10.1007/s00216-019-02091-8 Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Paper in Forefront
Proctor, Kathryn
Petrie, Bruce
Barden, Ruth
Arnot, Tom
Kasprzyk-Hordern, Barbara
Multi-residue ultra-performance liquid chromatography coupled with tandem mass spectrometry method for comprehensive multi-class anthropogenic compounds of emerging concern analysis in a catchment-based exposure-driven study
title Multi-residue ultra-performance liquid chromatography coupled with tandem mass spectrometry method for comprehensive multi-class anthropogenic compounds of emerging concern analysis in a catchment-based exposure-driven study
title_full Multi-residue ultra-performance liquid chromatography coupled with tandem mass spectrometry method for comprehensive multi-class anthropogenic compounds of emerging concern analysis in a catchment-based exposure-driven study
title_fullStr Multi-residue ultra-performance liquid chromatography coupled with tandem mass spectrometry method for comprehensive multi-class anthropogenic compounds of emerging concern analysis in a catchment-based exposure-driven study
title_full_unstemmed Multi-residue ultra-performance liquid chromatography coupled with tandem mass spectrometry method for comprehensive multi-class anthropogenic compounds of emerging concern analysis in a catchment-based exposure-driven study
title_short Multi-residue ultra-performance liquid chromatography coupled with tandem mass spectrometry method for comprehensive multi-class anthropogenic compounds of emerging concern analysis in a catchment-based exposure-driven study
title_sort multi-residue ultra-performance liquid chromatography coupled with tandem mass spectrometry method for comprehensive multi-class anthropogenic compounds of emerging concern analysis in a catchment-based exposure-driven study
topic Paper in Forefront
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6838033/
https://www.ncbi.nlm.nih.gov/pubmed/31494686
http://dx.doi.org/10.1007/s00216-019-02091-8
work_keys_str_mv AT proctorkathryn multiresidueultraperformanceliquidchromatographycoupledwithtandemmassspectrometrymethodforcomprehensivemulticlassanthropogeniccompoundsofemergingconcernanalysisinacatchmentbasedexposuredrivenstudy
AT petriebruce multiresidueultraperformanceliquidchromatographycoupledwithtandemmassspectrometrymethodforcomprehensivemulticlassanthropogeniccompoundsofemergingconcernanalysisinacatchmentbasedexposuredrivenstudy
AT bardenruth multiresidueultraperformanceliquidchromatographycoupledwithtandemmassspectrometrymethodforcomprehensivemulticlassanthropogeniccompoundsofemergingconcernanalysisinacatchmentbasedexposuredrivenstudy
AT arnottom multiresidueultraperformanceliquidchromatographycoupledwithtandemmassspectrometrymethodforcomprehensivemulticlassanthropogeniccompoundsofemergingconcernanalysisinacatchmentbasedexposuredrivenstudy
AT kasprzykhordernbarbara multiresidueultraperformanceliquidchromatographycoupledwithtandemmassspectrometrymethodforcomprehensivemulticlassanthropogeniccompoundsofemergingconcernanalysisinacatchmentbasedexposuredrivenstudy