Cargando…
Measuring Electric Charge and Molecular Coverage on Electrode Surface from Transient Induced Molecular Electronic Signal (TIMES)
Charge density and molecular coverage on the surface of electrode play major roles in the science and technology of surface chemistry and biochemical sensing. However, there has been no easy and direct method to characterize these quantities. By extending the method of Transient Induced Molecular El...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6838146/ https://www.ncbi.nlm.nih.gov/pubmed/31700032 http://dx.doi.org/10.1038/s41598-019-52588-6 |
_version_ | 1783467169723449344 |
---|---|
author | Chen, Ping-Wei Tseng, Chi-Yang Shi, Fumin Bi, Bo Lo, Yu-Hwa |
author_facet | Chen, Ping-Wei Tseng, Chi-Yang Shi, Fumin Bi, Bo Lo, Yu-Hwa |
author_sort | Chen, Ping-Wei |
collection | PubMed |
description | Charge density and molecular coverage on the surface of electrode play major roles in the science and technology of surface chemistry and biochemical sensing. However, there has been no easy and direct method to characterize these quantities. By extending the method of Transient Induced Molecular Electronic Signal (TIMES) which we have used to measure molecular interactions, we are able to quantify the amount of charge in the double layers at the solution/electrode interface for different buffer strengths, buffer types, and pH values. Most uniquely, such capabilities can be applied to study surface coverage of immobilized molecules. As an example, we have measured the surface coverage for thiol-modified single-strand deoxyribonucleic acid (ssDNA) as anchored probe and 6-Mercapto-1-hexanol (MCH) as blocking agent on the platinum surface. Through these experiments, we demonstrate that TIMES offers a simple and accurate method to quantify surface charge and coverage of molecules on a metal surface, as an enabling tool for studies of surface properties and surface functionalization for biochemical sensing and reactions. |
format | Online Article Text |
id | pubmed-6838146 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-68381462019-11-14 Measuring Electric Charge and Molecular Coverage on Electrode Surface from Transient Induced Molecular Electronic Signal (TIMES) Chen, Ping-Wei Tseng, Chi-Yang Shi, Fumin Bi, Bo Lo, Yu-Hwa Sci Rep Article Charge density and molecular coverage on the surface of electrode play major roles in the science and technology of surface chemistry and biochemical sensing. However, there has been no easy and direct method to characterize these quantities. By extending the method of Transient Induced Molecular Electronic Signal (TIMES) which we have used to measure molecular interactions, we are able to quantify the amount of charge in the double layers at the solution/electrode interface for different buffer strengths, buffer types, and pH values. Most uniquely, such capabilities can be applied to study surface coverage of immobilized molecules. As an example, we have measured the surface coverage for thiol-modified single-strand deoxyribonucleic acid (ssDNA) as anchored probe and 6-Mercapto-1-hexanol (MCH) as blocking agent on the platinum surface. Through these experiments, we demonstrate that TIMES offers a simple and accurate method to quantify surface charge and coverage of molecules on a metal surface, as an enabling tool for studies of surface properties and surface functionalization for biochemical sensing and reactions. Nature Publishing Group UK 2019-11-07 /pmc/articles/PMC6838146/ /pubmed/31700032 http://dx.doi.org/10.1038/s41598-019-52588-6 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Chen, Ping-Wei Tseng, Chi-Yang Shi, Fumin Bi, Bo Lo, Yu-Hwa Measuring Electric Charge and Molecular Coverage on Electrode Surface from Transient Induced Molecular Electronic Signal (TIMES) |
title | Measuring Electric Charge and Molecular Coverage on Electrode Surface from Transient Induced Molecular Electronic Signal (TIMES) |
title_full | Measuring Electric Charge and Molecular Coverage on Electrode Surface from Transient Induced Molecular Electronic Signal (TIMES) |
title_fullStr | Measuring Electric Charge and Molecular Coverage on Electrode Surface from Transient Induced Molecular Electronic Signal (TIMES) |
title_full_unstemmed | Measuring Electric Charge and Molecular Coverage on Electrode Surface from Transient Induced Molecular Electronic Signal (TIMES) |
title_short | Measuring Electric Charge and Molecular Coverage on Electrode Surface from Transient Induced Molecular Electronic Signal (TIMES) |
title_sort | measuring electric charge and molecular coverage on electrode surface from transient induced molecular electronic signal (times) |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6838146/ https://www.ncbi.nlm.nih.gov/pubmed/31700032 http://dx.doi.org/10.1038/s41598-019-52588-6 |
work_keys_str_mv | AT chenpingwei measuringelectricchargeandmolecularcoverageonelectrodesurfacefromtransientinducedmolecularelectronicsignaltimes AT tsengchiyang measuringelectricchargeandmolecularcoverageonelectrodesurfacefromtransientinducedmolecularelectronicsignaltimes AT shifumin measuringelectricchargeandmolecularcoverageonelectrodesurfacefromtransientinducedmolecularelectronicsignaltimes AT bibo measuringelectricchargeandmolecularcoverageonelectrodesurfacefromtransientinducedmolecularelectronicsignaltimes AT loyuhwa measuringelectricchargeandmolecularcoverageonelectrodesurfacefromtransientinducedmolecularelectronicsignaltimes |