Cargando…

Wearable Sensors in Ambulatory Individuals With a Spinal Cord Injury: From Energy Expenditure Estimation to Activity Recommendations

Inappropriate physical inactivity is a global health problem increasing the risk of cardiometabolic diseases. Wearable sensors show great potential to promote physical activity and thus a healthier lifestyle. While commercial activity trackers are available to estimate energy expenditure (EE) in non...

Descripción completa

Detalles Bibliográficos
Autores principales: Popp, Werner L., Schneider, Sophie, Bär, Jessica, Bösch, Philipp, Spengler, Christina M., Gassert, Roger, Curt, Armin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6838774/
https://www.ncbi.nlm.nih.gov/pubmed/31736845
http://dx.doi.org/10.3389/fneur.2019.01092
_version_ 1783467282022793216
author Popp, Werner L.
Schneider, Sophie
Bär, Jessica
Bösch, Philipp
Spengler, Christina M.
Gassert, Roger
Curt, Armin
author_facet Popp, Werner L.
Schneider, Sophie
Bär, Jessica
Bösch, Philipp
Spengler, Christina M.
Gassert, Roger
Curt, Armin
author_sort Popp, Werner L.
collection PubMed
description Inappropriate physical inactivity is a global health problem increasing the risk of cardiometabolic diseases. Wearable sensors show great potential to promote physical activity and thus a healthier lifestyle. While commercial activity trackers are available to estimate energy expenditure (EE) in non-disabled individuals, they are not designed for reliable assessments in individuals with an incomplete spinal cord injury (iSCI). Furthermore, activity recommendations for this population are currently rather vague and not tailored to their individual needs, and activity guidelines provided for the non-disabled population may not be easily translated for this population. However, especially in iSCI individuals with impaired abilities to stand and walk, the assessment of physical activities and appropriate recommendations for a healthy lifestyle are challenging. Therefore, the study aimed at developing an EE estimation model for iSCI individuals able to walk based on wearable sensor data. Additionally, the data collected within this study was used to translate common activity recommendations for the non-disabled population to easily understandable activity goals for ambulatory individuals with an iSCI. In total, 30 ambulatory individuals with an iSCI were equipped with wearable sensors while performing 12 different physical activities. EE was measured continuously and demographic and anthropometric variables, clinical assessment scores as well as wearable-sensor-derived features were used to develop different EE estimation models. The best EE estimation model comprised the estimation of resting EE using the updated Harris-Benedict equation, classifying activities using a k-nearest neighbor algorithm, and applying a multiple linear regression-based EE estimation model for each activity class. The mean absolute estimation error of this model was 15.2 ± 6.3% and the corresponding mean signed error was −3.4 ± 8.9%. Translating activity recommendations of global health institutions, we suggest a minimum of 2,000–3,000 steps per day for ambulatory individuals with an iSCI. If ambulatory individuals with an iSCI targeted the popular 10,000 steps a day recommendation for the non-disabled population, their equivalent would be around 8,000 steps a day. The combination of the presented dedicated EE estimation model for ambulatory individuals with an iSCI and the translated activity recommendations is an important step toward promoting an active lifestyle in this population.
format Online
Article
Text
id pubmed-6838774
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-68387742019-11-15 Wearable Sensors in Ambulatory Individuals With a Spinal Cord Injury: From Energy Expenditure Estimation to Activity Recommendations Popp, Werner L. Schneider, Sophie Bär, Jessica Bösch, Philipp Spengler, Christina M. Gassert, Roger Curt, Armin Front Neurol Neurology Inappropriate physical inactivity is a global health problem increasing the risk of cardiometabolic diseases. Wearable sensors show great potential to promote physical activity and thus a healthier lifestyle. While commercial activity trackers are available to estimate energy expenditure (EE) in non-disabled individuals, they are not designed for reliable assessments in individuals with an incomplete spinal cord injury (iSCI). Furthermore, activity recommendations for this population are currently rather vague and not tailored to their individual needs, and activity guidelines provided for the non-disabled population may not be easily translated for this population. However, especially in iSCI individuals with impaired abilities to stand and walk, the assessment of physical activities and appropriate recommendations for a healthy lifestyle are challenging. Therefore, the study aimed at developing an EE estimation model for iSCI individuals able to walk based on wearable sensor data. Additionally, the data collected within this study was used to translate common activity recommendations for the non-disabled population to easily understandable activity goals for ambulatory individuals with an iSCI. In total, 30 ambulatory individuals with an iSCI were equipped with wearable sensors while performing 12 different physical activities. EE was measured continuously and demographic and anthropometric variables, clinical assessment scores as well as wearable-sensor-derived features were used to develop different EE estimation models. The best EE estimation model comprised the estimation of resting EE using the updated Harris-Benedict equation, classifying activities using a k-nearest neighbor algorithm, and applying a multiple linear regression-based EE estimation model for each activity class. The mean absolute estimation error of this model was 15.2 ± 6.3% and the corresponding mean signed error was −3.4 ± 8.9%. Translating activity recommendations of global health institutions, we suggest a minimum of 2,000–3,000 steps per day for ambulatory individuals with an iSCI. If ambulatory individuals with an iSCI targeted the popular 10,000 steps a day recommendation for the non-disabled population, their equivalent would be around 8,000 steps a day. The combination of the presented dedicated EE estimation model for ambulatory individuals with an iSCI and the translated activity recommendations is an important step toward promoting an active lifestyle in this population. Frontiers Media S.A. 2019-11-01 /pmc/articles/PMC6838774/ /pubmed/31736845 http://dx.doi.org/10.3389/fneur.2019.01092 Text en Copyright © 2019 Popp, Schneider, Bär, Bösch, Spengler, Gassert and Curt. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Popp, Werner L.
Schneider, Sophie
Bär, Jessica
Bösch, Philipp
Spengler, Christina M.
Gassert, Roger
Curt, Armin
Wearable Sensors in Ambulatory Individuals With a Spinal Cord Injury: From Energy Expenditure Estimation to Activity Recommendations
title Wearable Sensors in Ambulatory Individuals With a Spinal Cord Injury: From Energy Expenditure Estimation to Activity Recommendations
title_full Wearable Sensors in Ambulatory Individuals With a Spinal Cord Injury: From Energy Expenditure Estimation to Activity Recommendations
title_fullStr Wearable Sensors in Ambulatory Individuals With a Spinal Cord Injury: From Energy Expenditure Estimation to Activity Recommendations
title_full_unstemmed Wearable Sensors in Ambulatory Individuals With a Spinal Cord Injury: From Energy Expenditure Estimation to Activity Recommendations
title_short Wearable Sensors in Ambulatory Individuals With a Spinal Cord Injury: From Energy Expenditure Estimation to Activity Recommendations
title_sort wearable sensors in ambulatory individuals with a spinal cord injury: from energy expenditure estimation to activity recommendations
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6838774/
https://www.ncbi.nlm.nih.gov/pubmed/31736845
http://dx.doi.org/10.3389/fneur.2019.01092
work_keys_str_mv AT poppwernerl wearablesensorsinambulatoryindividualswithaspinalcordinjuryfromenergyexpenditureestimationtoactivityrecommendations
AT schneidersophie wearablesensorsinambulatoryindividualswithaspinalcordinjuryfromenergyexpenditureestimationtoactivityrecommendations
AT barjessica wearablesensorsinambulatoryindividualswithaspinalcordinjuryfromenergyexpenditureestimationtoactivityrecommendations
AT boschphilipp wearablesensorsinambulatoryindividualswithaspinalcordinjuryfromenergyexpenditureestimationtoactivityrecommendations
AT spenglerchristinam wearablesensorsinambulatoryindividualswithaspinalcordinjuryfromenergyexpenditureestimationtoactivityrecommendations
AT gassertroger wearablesensorsinambulatoryindividualswithaspinalcordinjuryfromenergyexpenditureestimationtoactivityrecommendations
AT curtarmin wearablesensorsinambulatoryindividualswithaspinalcordinjuryfromenergyexpenditureestimationtoactivityrecommendations