Cargando…
Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study
OBJECTIVE: The effect of colonoscopy on colorectal cancer mortality is limited by several factors, among them a certain miss rate, leading to limited adenoma detection rates (ADRs). We investigated the effect of an automatic polyp detection system based on deep learning on polyp detection rate and A...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6839720/ https://www.ncbi.nlm.nih.gov/pubmed/30814121 http://dx.doi.org/10.1136/gutjnl-2018-317500 |
_version_ | 1783467482647887872 |
---|---|
author | Wang, Pu Berzin, Tyler M Glissen Brown, Jeremy Romek Bharadwaj, Shishira Becq, Aymeric Xiao, Xun Liu, Peixi Li, Liangping Song, Yan Zhang, Di Li, Yi Xu, Guangre Tu, Mengtian Liu, Xiaogang |
author_facet | Wang, Pu Berzin, Tyler M Glissen Brown, Jeremy Romek Bharadwaj, Shishira Becq, Aymeric Xiao, Xun Liu, Peixi Li, Liangping Song, Yan Zhang, Di Li, Yi Xu, Guangre Tu, Mengtian Liu, Xiaogang |
author_sort | Wang, Pu |
collection | PubMed |
description | OBJECTIVE: The effect of colonoscopy on colorectal cancer mortality is limited by several factors, among them a certain miss rate, leading to limited adenoma detection rates (ADRs). We investigated the effect of an automatic polyp detection system based on deep learning on polyp detection rate and ADR. DESIGN: In an open, non-blinded trial, consecutive patients were prospectively randomised to undergo diagnostic colonoscopy with or without assistance of a real-time automatic polyp detection system providing a simultaneous visual notice and sound alarm on polyp detection. The primary outcome was ADR. RESULTS: Of 1058 patients included, 536 were randomised to standard colonoscopy, and 522 were randomised to colonoscopy with computer-aided diagnosis. The artificial intelligence (AI) system significantly increased ADR (29.1%vs20.3%, p<0.001) and the mean number of adenomas per patient (0.53vs0.31, p<0.001). This was due to a higher number of diminutive adenomas found (185vs102; p<0.001), while there was no statistical difference in larger adenomas (77vs58, p=0.075). In addition, the number of hyperplastic polyps was also significantly increased (114vs52, p<0.001). CONCLUSIONS: In a low prevalent ADR population, an automatic polyp detection system during colonoscopy resulted in a significant increase in the number of diminutive adenomas detected, as well as an increase in the rate of hyperplastic polyps. The cost–benefit ratio of such effects has to be determined further. TRIAL REGISTRATION NUMBER: ChiCTR-DDD-17012221; Results. |
format | Online Article Text |
id | pubmed-6839720 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-68397202019-11-12 Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study Wang, Pu Berzin, Tyler M Glissen Brown, Jeremy Romek Bharadwaj, Shishira Becq, Aymeric Xiao, Xun Liu, Peixi Li, Liangping Song, Yan Zhang, Di Li, Yi Xu, Guangre Tu, Mengtian Liu, Xiaogang Gut Endoscopy OBJECTIVE: The effect of colonoscopy on colorectal cancer mortality is limited by several factors, among them a certain miss rate, leading to limited adenoma detection rates (ADRs). We investigated the effect of an automatic polyp detection system based on deep learning on polyp detection rate and ADR. DESIGN: In an open, non-blinded trial, consecutive patients were prospectively randomised to undergo diagnostic colonoscopy with or without assistance of a real-time automatic polyp detection system providing a simultaneous visual notice and sound alarm on polyp detection. The primary outcome was ADR. RESULTS: Of 1058 patients included, 536 were randomised to standard colonoscopy, and 522 were randomised to colonoscopy with computer-aided diagnosis. The artificial intelligence (AI) system significantly increased ADR (29.1%vs20.3%, p<0.001) and the mean number of adenomas per patient (0.53vs0.31, p<0.001). This was due to a higher number of diminutive adenomas found (185vs102; p<0.001), while there was no statistical difference in larger adenomas (77vs58, p=0.075). In addition, the number of hyperplastic polyps was also significantly increased (114vs52, p<0.001). CONCLUSIONS: In a low prevalent ADR population, an automatic polyp detection system during colonoscopy resulted in a significant increase in the number of diminutive adenomas detected, as well as an increase in the rate of hyperplastic polyps. The cost–benefit ratio of such effects has to be determined further. TRIAL REGISTRATION NUMBER: ChiCTR-DDD-17012221; Results. BMJ Publishing Group 2019-10 2019-02-27 /pmc/articles/PMC6839720/ /pubmed/30814121 http://dx.doi.org/10.1136/gutjnl-2018-317500 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Endoscopy Wang, Pu Berzin, Tyler M Glissen Brown, Jeremy Romek Bharadwaj, Shishira Becq, Aymeric Xiao, Xun Liu, Peixi Li, Liangping Song, Yan Zhang, Di Li, Yi Xu, Guangre Tu, Mengtian Liu, Xiaogang Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study |
title | Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study |
title_full | Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study |
title_fullStr | Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study |
title_full_unstemmed | Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study |
title_short | Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study |
title_sort | real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study |
topic | Endoscopy |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6839720/ https://www.ncbi.nlm.nih.gov/pubmed/30814121 http://dx.doi.org/10.1136/gutjnl-2018-317500 |
work_keys_str_mv | AT wangpu realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT berzintylerm realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT glissenbrownjeremyromek realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT bharadwajshishira realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT becqaymeric realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT xiaoxun realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT liupeixi realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT liliangping realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT songyan realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT zhangdi realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT liyi realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT xuguangre realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT tumengtian realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy AT liuxiaogang realtimeautomaticdetectionsystemincreasescolonoscopicpolypandadenomadetectionratesaprospectiverandomisedcontrolledstudy |