Cargando…
The clot thickens: Autologous and allogeneic fibrin sealants are mechanically equivalent in an ex vivo model of cartilage repair
Fibrin sealants are commonly used in cartilage repair surgeries to adhere cells or grafts into a cartilage defect. Both autologous and commercial allogeneic fibrin sealants are used in cartilage repair surgeries, yet there are no studies characterizing and comparing the mechanical properties of fibr...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6839864/ https://www.ncbi.nlm.nih.gov/pubmed/31703078 http://dx.doi.org/10.1371/journal.pone.0224756 |
_version_ | 1783467502996553728 |
---|---|
author | Irwin, Rebecca M. Bonassar, Lawrence J. Cohen, Itai Matuska, Andrea M. Commins, Jacqueline Cole, Brian Fortier, Lisa A. |
author_facet | Irwin, Rebecca M. Bonassar, Lawrence J. Cohen, Itai Matuska, Andrea M. Commins, Jacqueline Cole, Brian Fortier, Lisa A. |
author_sort | Irwin, Rebecca M. |
collection | PubMed |
description | Fibrin sealants are commonly used in cartilage repair surgeries to adhere cells or grafts into a cartilage defect. Both autologous and commercial allogeneic fibrin sealants are used in cartilage repair surgeries, yet there are no studies characterizing and comparing the mechanical properties of fibrin sealants from all-autologous sources. The objectives of this study were to investigate (i) the effect of fibrinogen and thrombin sources on failure mechanics of sealants, and (ii) how sealants affect the adhesion of particulated cartilage graft material (BioCartilage) to surrounding cartilage under physiological loading. Allogeneic thrombin and fibrinogen were purchased (Tisseel), and autologous sources were prepared from platelet-rich plasma (PRP) and platelet-poor plasma (PPP) generated from human blood. To compare failure characteristics, sealants were sandwiched between cartilage explants and pulled to failure. The effect of sealant on the adhesion of BioCartilage graft to cartilage was determined by quantifying microscale strains at the graft-cartilage interface using an in vitro cartilage defect model subjected to shear loading at physiological strains well below failure thresholds. Fibrinogen sources were not equivalent; PRP fibrinogen created sealants that were more brittle, failed at lower strains, and resulted in sustained higher strains through the graft-cartilage interface depth compared to PPP and allogeneic sources. PPP clotted slower compared to PRP, suggesting PPP may percolate deeper into the repair to provide more stability through the tissue depth. There was no difference in bulk failure properties or microscale strains at the graft-cartilage interface between the purely autologous sealant (autologous thrombin + PPP fibrinogen) and the commercial allogeneic sealant. Clinical Significance: All-autologous fibrin sealants fabricated with PPP have comparable adhesion strength as commercial allogeneic sealants in vitro, whereas PRP creates an inferior all-autologous sealant that sustains higher strains through the graft-cartilage interface depth. |
format | Online Article Text |
id | pubmed-6839864 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-68398642019-11-15 The clot thickens: Autologous and allogeneic fibrin sealants are mechanically equivalent in an ex vivo model of cartilage repair Irwin, Rebecca M. Bonassar, Lawrence J. Cohen, Itai Matuska, Andrea M. Commins, Jacqueline Cole, Brian Fortier, Lisa A. PLoS One Research Article Fibrin sealants are commonly used in cartilage repair surgeries to adhere cells or grafts into a cartilage defect. Both autologous and commercial allogeneic fibrin sealants are used in cartilage repair surgeries, yet there are no studies characterizing and comparing the mechanical properties of fibrin sealants from all-autologous sources. The objectives of this study were to investigate (i) the effect of fibrinogen and thrombin sources on failure mechanics of sealants, and (ii) how sealants affect the adhesion of particulated cartilage graft material (BioCartilage) to surrounding cartilage under physiological loading. Allogeneic thrombin and fibrinogen were purchased (Tisseel), and autologous sources were prepared from platelet-rich plasma (PRP) and platelet-poor plasma (PPP) generated from human blood. To compare failure characteristics, sealants were sandwiched between cartilage explants and pulled to failure. The effect of sealant on the adhesion of BioCartilage graft to cartilage was determined by quantifying microscale strains at the graft-cartilage interface using an in vitro cartilage defect model subjected to shear loading at physiological strains well below failure thresholds. Fibrinogen sources were not equivalent; PRP fibrinogen created sealants that were more brittle, failed at lower strains, and resulted in sustained higher strains through the graft-cartilage interface depth compared to PPP and allogeneic sources. PPP clotted slower compared to PRP, suggesting PPP may percolate deeper into the repair to provide more stability through the tissue depth. There was no difference in bulk failure properties or microscale strains at the graft-cartilage interface between the purely autologous sealant (autologous thrombin + PPP fibrinogen) and the commercial allogeneic sealant. Clinical Significance: All-autologous fibrin sealants fabricated with PPP have comparable adhesion strength as commercial allogeneic sealants in vitro, whereas PRP creates an inferior all-autologous sealant that sustains higher strains through the graft-cartilage interface depth. Public Library of Science 2019-11-08 /pmc/articles/PMC6839864/ /pubmed/31703078 http://dx.doi.org/10.1371/journal.pone.0224756 Text en © 2019 Irwin et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Irwin, Rebecca M. Bonassar, Lawrence J. Cohen, Itai Matuska, Andrea M. Commins, Jacqueline Cole, Brian Fortier, Lisa A. The clot thickens: Autologous and allogeneic fibrin sealants are mechanically equivalent in an ex vivo model of cartilage repair |
title | The clot thickens: Autologous and allogeneic fibrin sealants are mechanically equivalent in an ex vivo model of cartilage repair |
title_full | The clot thickens: Autologous and allogeneic fibrin sealants are mechanically equivalent in an ex vivo model of cartilage repair |
title_fullStr | The clot thickens: Autologous and allogeneic fibrin sealants are mechanically equivalent in an ex vivo model of cartilage repair |
title_full_unstemmed | The clot thickens: Autologous and allogeneic fibrin sealants are mechanically equivalent in an ex vivo model of cartilage repair |
title_short | The clot thickens: Autologous and allogeneic fibrin sealants are mechanically equivalent in an ex vivo model of cartilage repair |
title_sort | clot thickens: autologous and allogeneic fibrin sealants are mechanically equivalent in an ex vivo model of cartilage repair |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6839864/ https://www.ncbi.nlm.nih.gov/pubmed/31703078 http://dx.doi.org/10.1371/journal.pone.0224756 |
work_keys_str_mv | AT irwinrebeccam theclotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT bonassarlawrencej theclotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT cohenitai theclotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT matuskaandream theclotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT comminsjacqueline theclotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT colebrian theclotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT fortierlisaa theclotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT irwinrebeccam clotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT bonassarlawrencej clotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT cohenitai clotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT matuskaandream clotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT comminsjacqueline clotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT colebrian clotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair AT fortierlisaa clotthickensautologousandallogeneicfibrinsealantsaremechanicallyequivalentinanexvivomodelofcartilagerepair |