Cargando…
VALIDATION OF A WALKING SPEED MEASUREMENT DEVICE: GAITBOX
The NIH 4m Walk Test is a clinically validated tool to measure adult walking speed. Human reaction limitations can contribute to measurement error when manually timing gait speed. This is important considering a 0.10m/s decrease in walking speed is associated with a 12% decrease in life expectancy f...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6840069/ http://dx.doi.org/10.1093/geroni/igz038.031 |
_version_ | 1783467538553765888 |
---|---|
author | Jarvis, Leighanne Peterson, Matthew J Morey, Miriam C Caves, Kevin |
author_facet | Jarvis, Leighanne Peterson, Matthew J Morey, Miriam C Caves, Kevin |
author_sort | Jarvis, Leighanne |
collection | PubMed |
description | The NIH 4m Walk Test is a clinically validated tool to measure adult walking speed. Human reaction limitations can contribute to measurement error when manually timing gait speed. This is important considering a 0.10m/s decrease in walking speed is associated with a 12% decrease in life expectancy for older adults. The goal of this study was to validate a low cost, custom built device, Gait Box (GB), compared to human timer (HT) and a research grade Sprint Timing System (STS) with an older adult (mean 72.4 + 7.4 years of age) population (N = 35). Validity was assessed via accuracy (correlations), precision (mean differences), and bias (Bland-Altman plots). Results showed strong correlations between the GB and HT (0.99) and the GB and STS (0.98), with negligible mean differences. This demonstrates the GB can be used to accurately and precisely measure gait speed in clinical and research settings. |
format | Online Article Text |
id | pubmed-6840069 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-68400692019-11-13 VALIDATION OF A WALKING SPEED MEASUREMENT DEVICE: GAITBOX Jarvis, Leighanne Peterson, Matthew J Morey, Miriam C Caves, Kevin Innov Aging Session 530 (Symposium) The NIH 4m Walk Test is a clinically validated tool to measure adult walking speed. Human reaction limitations can contribute to measurement error when manually timing gait speed. This is important considering a 0.10m/s decrease in walking speed is associated with a 12% decrease in life expectancy for older adults. The goal of this study was to validate a low cost, custom built device, Gait Box (GB), compared to human timer (HT) and a research grade Sprint Timing System (STS) with an older adult (mean 72.4 + 7.4 years of age) population (N = 35). Validity was assessed via accuracy (correlations), precision (mean differences), and bias (Bland-Altman plots). Results showed strong correlations between the GB and HT (0.99) and the GB and STS (0.98), with negligible mean differences. This demonstrates the GB can be used to accurately and precisely measure gait speed in clinical and research settings. Oxford University Press 2019-11-08 /pmc/articles/PMC6840069/ http://dx.doi.org/10.1093/geroni/igz038.031 Text en © The Author(s) 2019. Published by Oxford University Press on behalf of The Gerontological Society of America. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Session 530 (Symposium) Jarvis, Leighanne Peterson, Matthew J Morey, Miriam C Caves, Kevin VALIDATION OF A WALKING SPEED MEASUREMENT DEVICE: GAITBOX |
title | VALIDATION OF A WALKING SPEED MEASUREMENT DEVICE: GAITBOX |
title_full | VALIDATION OF A WALKING SPEED MEASUREMENT DEVICE: GAITBOX |
title_fullStr | VALIDATION OF A WALKING SPEED MEASUREMENT DEVICE: GAITBOX |
title_full_unstemmed | VALIDATION OF A WALKING SPEED MEASUREMENT DEVICE: GAITBOX |
title_short | VALIDATION OF A WALKING SPEED MEASUREMENT DEVICE: GAITBOX |
title_sort | validation of a walking speed measurement device: gaitbox |
topic | Session 530 (Symposium) |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6840069/ http://dx.doi.org/10.1093/geroni/igz038.031 |
work_keys_str_mv | AT jarvisleighanne validationofawalkingspeedmeasurementdevicegaitbox AT petersonmatthewj validationofawalkingspeedmeasurementdevicegaitbox AT moreymiriamc validationofawalkingspeedmeasurementdevicegaitbox AT caveskevin validationofawalkingspeedmeasurementdevicegaitbox |