Cargando…

ACTIGRAPH’S LOW-FREQUENCY EXTENSION FILTER FOR ESTIMATING WRIST-WORN PHYSICAL ACTIVITY IN OLDER ADULTS

Advancements in body-worn activity devices make them valuable for objective physical activity measurement. Research-grade monitors utilize software algorithms developed with younger populations using waist-worn devices. ActiGraph offers the low frequency extension (LFE) filter which reduces the move...

Descripción completa

Detalles Bibliográficos
Autores principales: Hicks, Hilary J, Laffer, Alex, Losinski, Genna, Watts, Amber
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6841388/
http://dx.doi.org/10.1093/geroni/igz038.1918
_version_ 1783467871545851904
author Hicks, Hilary J
Laffer, Alex
Losinski, Genna
Watts, Amber
author_facet Hicks, Hilary J
Laffer, Alex
Losinski, Genna
Watts, Amber
author_sort Hicks, Hilary J
collection PubMed
description Advancements in body-worn activity devices make them valuable for objective physical activity measurement. Research-grade monitors utilize software algorithms developed with younger populations using waist-worn devices. ActiGraph offers the low frequency extension (LFE) filter which reduces the movement threshold to capture low acceleration activity that is more common in older adults. It is unclear how this filter changes activity variable calculations in older adults. We investigated the effects of the LFE filter on wrist-worn activity estimates in this population. Participants were 21 older adults who wore the GT9X on their non-dominant wrist for 7 days in a free-living environment. Activity counts were estimated both with and without the LFE filter. Paired samples t-tests revealed that the LFE estimated significantly higher number of counts than non-LFE calculated counts per minute on all three axes (p < .001). Step count estimates were higher with (M = 20,780.09, SD = 5300.85) vs. without (M = 10,896.54, SD = 3489.45) the LFE filter, (t (20) = -22.21, p < .001). These differences have implications for calculations based on axis counts (e.g., Axis-1 calculated steps, intensity level classifications) that rely on waist-worn standards. For example, even without the filter, the GT9X calculated an average of 10,897 steps, which is likely an overestimate in this population. This suggests that axes-based variables should be interpreted with caution when generated with wrist-worn data, and future studies should aim to develop separate wrist and waist-worn standard estimates of these variables in older adult populations.
format Online
Article
Text
id pubmed-6841388
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-68413882019-11-15 ACTIGRAPH’S LOW-FREQUENCY EXTENSION FILTER FOR ESTIMATING WRIST-WORN PHYSICAL ACTIVITY IN OLDER ADULTS Hicks, Hilary J Laffer, Alex Losinski, Genna Watts, Amber Innov Aging Session 2410 (Poster) Advancements in body-worn activity devices make them valuable for objective physical activity measurement. Research-grade monitors utilize software algorithms developed with younger populations using waist-worn devices. ActiGraph offers the low frequency extension (LFE) filter which reduces the movement threshold to capture low acceleration activity that is more common in older adults. It is unclear how this filter changes activity variable calculations in older adults. We investigated the effects of the LFE filter on wrist-worn activity estimates in this population. Participants were 21 older adults who wore the GT9X on their non-dominant wrist for 7 days in a free-living environment. Activity counts were estimated both with and without the LFE filter. Paired samples t-tests revealed that the LFE estimated significantly higher number of counts than non-LFE calculated counts per minute on all three axes (p < .001). Step count estimates were higher with (M = 20,780.09, SD = 5300.85) vs. without (M = 10,896.54, SD = 3489.45) the LFE filter, (t (20) = -22.21, p < .001). These differences have implications for calculations based on axis counts (e.g., Axis-1 calculated steps, intensity level classifications) that rely on waist-worn standards. For example, even without the filter, the GT9X calculated an average of 10,897 steps, which is likely an overestimate in this population. This suggests that axes-based variables should be interpreted with caution when generated with wrist-worn data, and future studies should aim to develop separate wrist and waist-worn standard estimates of these variables in older adult populations. Oxford University Press 2019-11-08 /pmc/articles/PMC6841388/ http://dx.doi.org/10.1093/geroni/igz038.1918 Text en © The Author(s) 2019. Published by Oxford University Press on behalf of The Gerontological Society of America. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Session 2410 (Poster)
Hicks, Hilary J
Laffer, Alex
Losinski, Genna
Watts, Amber
ACTIGRAPH’S LOW-FREQUENCY EXTENSION FILTER FOR ESTIMATING WRIST-WORN PHYSICAL ACTIVITY IN OLDER ADULTS
title ACTIGRAPH’S LOW-FREQUENCY EXTENSION FILTER FOR ESTIMATING WRIST-WORN PHYSICAL ACTIVITY IN OLDER ADULTS
title_full ACTIGRAPH’S LOW-FREQUENCY EXTENSION FILTER FOR ESTIMATING WRIST-WORN PHYSICAL ACTIVITY IN OLDER ADULTS
title_fullStr ACTIGRAPH’S LOW-FREQUENCY EXTENSION FILTER FOR ESTIMATING WRIST-WORN PHYSICAL ACTIVITY IN OLDER ADULTS
title_full_unstemmed ACTIGRAPH’S LOW-FREQUENCY EXTENSION FILTER FOR ESTIMATING WRIST-WORN PHYSICAL ACTIVITY IN OLDER ADULTS
title_short ACTIGRAPH’S LOW-FREQUENCY EXTENSION FILTER FOR ESTIMATING WRIST-WORN PHYSICAL ACTIVITY IN OLDER ADULTS
title_sort actigraph’s low-frequency extension filter for estimating wrist-worn physical activity in older adults
topic Session 2410 (Poster)
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6841388/
http://dx.doi.org/10.1093/geroni/igz038.1918
work_keys_str_mv AT hickshilaryj actigraphslowfrequencyextensionfilterforestimatingwristwornphysicalactivityinolderadults
AT lafferalex actigraphslowfrequencyextensionfilterforestimatingwristwornphysicalactivityinolderadults
AT losinskigenna actigraphslowfrequencyextensionfilterforestimatingwristwornphysicalactivityinolderadults
AT wattsamber actigraphslowfrequencyextensionfilterforestimatingwristwornphysicalactivityinolderadults