[Image: see text] Robust HU‐based CT ventilation from an integrated mass conservation formulation

Computed tomography (CT) ventilation algorithms estimate volume changes induced by respiratory motion. Existing Hounsfield Unit (HU) methods approximate volume change from the measured HU variations between spatially corresponding voxel locations within a temporally resolved CT image pair, assuming...

Descripción completa

Detalles Bibliográficos
Autores principales: Castillo, Edward, Vinogradskiy, Yevgeniy, Castillo, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6842051/
https://www.ncbi.nlm.nih.gov/pubmed/31514235
http://dx.doi.org/10.1002/mp.13817
_version_ 1783467983852535808
author Castillo, Edward
Vinogradskiy, Yevgeniy
Castillo, Richard
author_facet Castillo, Edward
Vinogradskiy, Yevgeniy
Castillo, Richard
author_sort Castillo, Edward
collection PubMed
description Computed tomography (CT) ventilation algorithms estimate volume changes induced by respiratory motion. Existing Hounsfield Unit (HU) methods approximate volume change from the measured HU variations between spatially corresponding voxel locations within a temporally resolved CT image pair, assuming that volume changes are caused solely by changes in air content. Numerical implementations require a deformable image registration to determine the inhale/exhale spatial correspondence, a preprocessing lung volume segmentation, a preprocessing high‐intensity vessel segmentation, and a post‐processing smoothing applied to the raw volume change estimates obtained for each lung tissue voxel. PURPOSE: We introduce the novel mass‐conserving volume change (MCVC) method for estimating voxel volume changes from the HU values within an inhale/exhale CT image pair. MCVC is based on subregional volume change estimates that possess quantitatively characterized and controllable levels of uncertainty. MCVC is therefore robust to small variations in DIR solutions and the resulting ventilation images are overall more reproducible. In contrast to existing HU methods, MCVC does not require a preprocessing lung vessel segmentation or pre/post‐processing Gaussian smoothing. METHODS: Subregional volume change estimates are defined in terms of mean density ratios. As such, the corresponding uncertainty is characterized using Gaussian statistics and standard error analysis of the sample density means. A numerical solution is obtained from the MCVC formulation by solving a constrained linear least squares problem defined by a series of subregional volume change estimates. Reproducibility of the MCVC method with respect to DIR solution was assessed using expert‐determined landmark point pairs and inhale/exhale phases from 10 four‐dimensional CTs (4DCTs) available on http://www.dir-lab.com. MCVC was also compared to the robust Integrated Jacobian Formulation (IJF), a transformation‐based ventilation method. RESULTS: The ten Dir‐Lab 4DCT cases were registered twice with the same DIR algorithm, but using different degrees of freedom (DIR 1 and DIR 2). Standard HU ventilation (HUV) and MCVC ventilation images were computed for both solutions. The average spatial errors (300 landmarks per case) for DIR 1 ranged between 0.74 and 1.50 mm, whereas for DIR 2 they ranged between 0.68 and 1.18 mm. Despite the differences in spatial errors between the two DIR solutions, the average Pearson correlation between the corresponding HUV images was 0.94 (0.03), while for the MCVC images it was 1.00 (0.00). The average correlation between MCVC and IJF ventilation over the ten test cases was 0.81 (0.14), whereas for HUV and IJF it was 0.56 (1.11). CONCLUSION: While HUV is robust to DIR solution, its implementation depends on heuristic Gaussian smoothing and vessel segmentation. MCVC is based on subregional volume change measurements with quantifiable and controllable levels of uncertainty. The subregional approach eliminates the need for Gaussian smoothing and lung vasculature segmentation. Numerical experiments are consistent with the underlying mathematical theory and indicate that MCVC ventilation is more reproducible with respect to DIR algorithm than standard HU methods. MCVC results are also more consistent with the robust IJF method, which suggests that incorporating robustness leads to more consistent results across both DIRs and ventilation algorithms.
format Online
Article
Text
id pubmed-6842051
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-68420512019-12-20 [Image: see text] Robust HU‐based CT ventilation from an integrated mass conservation formulation Castillo, Edward Vinogradskiy, Yevgeniy Castillo, Richard Med Phys QUANTITATIVE IMAGING AND IMAGE PROCESSING Computed tomography (CT) ventilation algorithms estimate volume changes induced by respiratory motion. Existing Hounsfield Unit (HU) methods approximate volume change from the measured HU variations between spatially corresponding voxel locations within a temporally resolved CT image pair, assuming that volume changes are caused solely by changes in air content. Numerical implementations require a deformable image registration to determine the inhale/exhale spatial correspondence, a preprocessing lung volume segmentation, a preprocessing high‐intensity vessel segmentation, and a post‐processing smoothing applied to the raw volume change estimates obtained for each lung tissue voxel. PURPOSE: We introduce the novel mass‐conserving volume change (MCVC) method for estimating voxel volume changes from the HU values within an inhale/exhale CT image pair. MCVC is based on subregional volume change estimates that possess quantitatively characterized and controllable levels of uncertainty. MCVC is therefore robust to small variations in DIR solutions and the resulting ventilation images are overall more reproducible. In contrast to existing HU methods, MCVC does not require a preprocessing lung vessel segmentation or pre/post‐processing Gaussian smoothing. METHODS: Subregional volume change estimates are defined in terms of mean density ratios. As such, the corresponding uncertainty is characterized using Gaussian statistics and standard error analysis of the sample density means. A numerical solution is obtained from the MCVC formulation by solving a constrained linear least squares problem defined by a series of subregional volume change estimates. Reproducibility of the MCVC method with respect to DIR solution was assessed using expert‐determined landmark point pairs and inhale/exhale phases from 10 four‐dimensional CTs (4DCTs) available on http://www.dir-lab.com. MCVC was also compared to the robust Integrated Jacobian Formulation (IJF), a transformation‐based ventilation method. RESULTS: The ten Dir‐Lab 4DCT cases were registered twice with the same DIR algorithm, but using different degrees of freedom (DIR 1 and DIR 2). Standard HU ventilation (HUV) and MCVC ventilation images were computed for both solutions. The average spatial errors (300 landmarks per case) for DIR 1 ranged between 0.74 and 1.50 mm, whereas for DIR 2 they ranged between 0.68 and 1.18 mm. Despite the differences in spatial errors between the two DIR solutions, the average Pearson correlation between the corresponding HUV images was 0.94 (0.03), while for the MCVC images it was 1.00 (0.00). The average correlation between MCVC and IJF ventilation over the ten test cases was 0.81 (0.14), whereas for HUV and IJF it was 0.56 (1.11). CONCLUSION: While HUV is robust to DIR solution, its implementation depends on heuristic Gaussian smoothing and vessel segmentation. MCVC is based on subregional volume change measurements with quantifiable and controllable levels of uncertainty. The subregional approach eliminates the need for Gaussian smoothing and lung vasculature segmentation. Numerical experiments are consistent with the underlying mathematical theory and indicate that MCVC ventilation is more reproducible with respect to DIR algorithm than standard HU methods. MCVC results are also more consistent with the robust IJF method, which suggests that incorporating robustness leads to more consistent results across both DIRs and ventilation algorithms. John Wiley and Sons Inc. 2019-09-28 2019-11 /pmc/articles/PMC6842051/ /pubmed/31514235 http://dx.doi.org/10.1002/mp.13817 Text en © 2019 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle QUANTITATIVE IMAGING AND IMAGE PROCESSING
Castillo, Edward
Vinogradskiy, Yevgeniy
Castillo, Richard
[Image: see text] Robust HU‐based CT ventilation from an integrated mass conservation formulation
title [Image: see text] Robust HU‐based CT ventilation from an integrated mass conservation formulation
title_full [Image: see text] Robust HU‐based CT ventilation from an integrated mass conservation formulation
title_fullStr [Image: see text] Robust HU‐based CT ventilation from an integrated mass conservation formulation
title_full_unstemmed [Image: see text] Robust HU‐based CT ventilation from an integrated mass conservation formulation
title_short [Image: see text] Robust HU‐based CT ventilation from an integrated mass conservation formulation
title_sort [image: see text] robust hu‐based ct ventilation from an integrated mass conservation formulation
topic QUANTITATIVE IMAGING AND IMAGE PROCESSING
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6842051/
https://www.ncbi.nlm.nih.gov/pubmed/31514235
http://dx.doi.org/10.1002/mp.13817
work_keys_str_mv AT castilloedward imageseetextrobusthubasedctventilationfromanintegratedmassconservationformulation
AT vinogradskiyyevgeniy imageseetextrobusthubasedctventilationfromanintegratedmassconservationformulation
AT castillorichard imageseetextrobusthubasedctventilationfromanintegratedmassconservationformulation