Cargando…

Quantitative lung morphology: semi-automated measurement of mean linear intercept

BACKGROUND: Quantifying morphologic changes is critical to our understanding of the pathophysiology of the lung. Mean linear intercept (MLI) measures are important in the assessment of clinically relevant pathology, such as emphysema. However, qualitative measures are prone to error and bias, while...

Descripción completa

Detalles Bibliográficos
Autores principales: Crowley, George, Kwon, Sophia, Caraher, Erin J., Haider, Syed Hissam, Lam, Rachel, Batra, Prag, Melles, Daniel, Liu, Mengling, Nolan, Anna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6842138/
https://www.ncbi.nlm.nih.gov/pubmed/31706309
http://dx.doi.org/10.1186/s12890-019-0915-6
Descripción
Sumario:BACKGROUND: Quantifying morphologic changes is critical to our understanding of the pathophysiology of the lung. Mean linear intercept (MLI) measures are important in the assessment of clinically relevant pathology, such as emphysema. However, qualitative measures are prone to error and bias, while quantitative methods such as mean linear intercept (MLI) are manually time consuming. Furthermore, a fully automated, reliable method of assessment is nontrivial and resource-intensive. METHODS: We propose a semi-automated method to quantify MLI that does not require specialized computer knowledge and uses a free, open-source image-processor (Fiji). We tested the method with a computer-generated, idealized dataset, derived an MLI usage guide, and successfully applied this method to a murine model of particulate matter (PM) exposure. Fields of randomly placed, uniform-radius circles were analyzed. Optimal numbers of chords to assess based on MLI were found via receiver-operator-characteristic (ROC)-area under the curve (AUC) analysis. Intraclass correlation coefficient (ICC) measured reliability. RESULTS: We demonstrate high accuracy (AUC(ROC) > 0.8 for MLI(actual) > 63.83 pixels) and excellent reliability (ICC = 0.9998, p < 0.0001). We provide a guide to optimize the number of chords to sample based on MLI. Processing time was 0.03 s/image. We showed elevated MLI in PM-exposed mice compared to PBS-exposed controls. We have also provided the macros that were used and have made an ImageJ plugin available free for academic research use at https://med.nyu.edu/nolanlab. CONCLUSIONS: Our semi-automated method is reliable, equally fast as fully automated methods, and uses free, open-source software. Additionally, we quantified the optimal number of chords that should be measured per lung field. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12890-019-0915-6) contains supplementary material, which is available to authorized users.