Cargando…

Establishment and validation of a nomogram model for aseptic loosening after tumor prosthetic replacement around the knee: a retrospective analysis

BACKGROUND: Aseptic loosening has become the main cause of prosthetic failure in medium- to long-term follow-up. The objective of this study was to establish and validate a nomogram model for aseptic loosening after tumor prosthetic replacement around knee. METHODS: We collected data on patients who...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Hao-ran, Wang, Feng, Yang, Xiong-gang, Xu, Ming-you, Qiao, Rui-qi, Li, Ji-kai, Zhao, Yun-long, Pang, Cheng-gang, Yu, Xiu-chun, Hu, Yong-cheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6842550/
https://www.ncbi.nlm.nih.gov/pubmed/31706336
http://dx.doi.org/10.1186/s13018-019-1423-3
_version_ 1783468064970375168
author Zhang, Hao-ran
Wang, Feng
Yang, Xiong-gang
Xu, Ming-you
Qiao, Rui-qi
Li, Ji-kai
Zhao, Yun-long
Pang, Cheng-gang
Yu, Xiu-chun
Hu, Yong-cheng
author_facet Zhang, Hao-ran
Wang, Feng
Yang, Xiong-gang
Xu, Ming-you
Qiao, Rui-qi
Li, Ji-kai
Zhao, Yun-long
Pang, Cheng-gang
Yu, Xiu-chun
Hu, Yong-cheng
author_sort Zhang, Hao-ran
collection PubMed
description BACKGROUND: Aseptic loosening has become the main cause of prosthetic failure in medium- to long-term follow-up. The objective of this study was to establish and validate a nomogram model for aseptic loosening after tumor prosthetic replacement around knee. METHODS: We collected data on patients who underwent tumor prosthetic replacements. The following risk factors were analyzed: tumor site, stem length, resection length, prosthetic motion mode, sex, age, extra-cortical grafting, custom or modular, stem diameter, stem material, tumor type, activity intensity, and BMI. We used univariate and multivariate Cox regression for analysis. Finally, the significant risk factors were used to establish the nomogram model. RESULTS: The stem length, resection length, tumor site, and prosthetic motion mode showed a tendency to be related to aseptic loosening, according to the univariate analysis. Multivariate analysis showed that the tumor site, stem length, and prosthetic motion mode were independent risk factors. The internal validation indicated that the nomogram model had acceptable predictive accuracy. CONCLUSIONS: A nomogram model was developed for predicting the prosthetic survival rate without aseptic loosening. Patients with distal femoral tumors and those who are applied with fixed hinge and short-stem prostheses are more likely to be exposed to aseptic loosening.
format Online
Article
Text
id pubmed-6842550
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-68425502019-11-14 Establishment and validation of a nomogram model for aseptic loosening after tumor prosthetic replacement around the knee: a retrospective analysis Zhang, Hao-ran Wang, Feng Yang, Xiong-gang Xu, Ming-you Qiao, Rui-qi Li, Ji-kai Zhao, Yun-long Pang, Cheng-gang Yu, Xiu-chun Hu, Yong-cheng J Orthop Surg Res Research Article BACKGROUND: Aseptic loosening has become the main cause of prosthetic failure in medium- to long-term follow-up. The objective of this study was to establish and validate a nomogram model for aseptic loosening after tumor prosthetic replacement around knee. METHODS: We collected data on patients who underwent tumor prosthetic replacements. The following risk factors were analyzed: tumor site, stem length, resection length, prosthetic motion mode, sex, age, extra-cortical grafting, custom or modular, stem diameter, stem material, tumor type, activity intensity, and BMI. We used univariate and multivariate Cox regression for analysis. Finally, the significant risk factors were used to establish the nomogram model. RESULTS: The stem length, resection length, tumor site, and prosthetic motion mode showed a tendency to be related to aseptic loosening, according to the univariate analysis. Multivariate analysis showed that the tumor site, stem length, and prosthetic motion mode were independent risk factors. The internal validation indicated that the nomogram model had acceptable predictive accuracy. CONCLUSIONS: A nomogram model was developed for predicting the prosthetic survival rate without aseptic loosening. Patients with distal femoral tumors and those who are applied with fixed hinge and short-stem prostheses are more likely to be exposed to aseptic loosening. BioMed Central 2019-11-09 /pmc/articles/PMC6842550/ /pubmed/31706336 http://dx.doi.org/10.1186/s13018-019-1423-3 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Zhang, Hao-ran
Wang, Feng
Yang, Xiong-gang
Xu, Ming-you
Qiao, Rui-qi
Li, Ji-kai
Zhao, Yun-long
Pang, Cheng-gang
Yu, Xiu-chun
Hu, Yong-cheng
Establishment and validation of a nomogram model for aseptic loosening after tumor prosthetic replacement around the knee: a retrospective analysis
title Establishment and validation of a nomogram model for aseptic loosening after tumor prosthetic replacement around the knee: a retrospective analysis
title_full Establishment and validation of a nomogram model for aseptic loosening after tumor prosthetic replacement around the knee: a retrospective analysis
title_fullStr Establishment and validation of a nomogram model for aseptic loosening after tumor prosthetic replacement around the knee: a retrospective analysis
title_full_unstemmed Establishment and validation of a nomogram model for aseptic loosening after tumor prosthetic replacement around the knee: a retrospective analysis
title_short Establishment and validation of a nomogram model for aseptic loosening after tumor prosthetic replacement around the knee: a retrospective analysis
title_sort establishment and validation of a nomogram model for aseptic loosening after tumor prosthetic replacement around the knee: a retrospective analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6842550/
https://www.ncbi.nlm.nih.gov/pubmed/31706336
http://dx.doi.org/10.1186/s13018-019-1423-3
work_keys_str_mv AT zhanghaoran establishmentandvalidationofanomogrammodelforasepticlooseningaftertumorprostheticreplacementaroundthekneearetrospectiveanalysis
AT wangfeng establishmentandvalidationofanomogrammodelforasepticlooseningaftertumorprostheticreplacementaroundthekneearetrospectiveanalysis
AT yangxionggang establishmentandvalidationofanomogrammodelforasepticlooseningaftertumorprostheticreplacementaroundthekneearetrospectiveanalysis
AT xumingyou establishmentandvalidationofanomogrammodelforasepticlooseningaftertumorprostheticreplacementaroundthekneearetrospectiveanalysis
AT qiaoruiqi establishmentandvalidationofanomogrammodelforasepticlooseningaftertumorprostheticreplacementaroundthekneearetrospectiveanalysis
AT lijikai establishmentandvalidationofanomogrammodelforasepticlooseningaftertumorprostheticreplacementaroundthekneearetrospectiveanalysis
AT zhaoyunlong establishmentandvalidationofanomogrammodelforasepticlooseningaftertumorprostheticreplacementaroundthekneearetrospectiveanalysis
AT pangchenggang establishmentandvalidationofanomogrammodelforasepticlooseningaftertumorprostheticreplacementaroundthekneearetrospectiveanalysis
AT yuxiuchun establishmentandvalidationofanomogrammodelforasepticlooseningaftertumorprostheticreplacementaroundthekneearetrospectiveanalysis
AT huyongcheng establishmentandvalidationofanomogrammodelforasepticlooseningaftertumorprostheticreplacementaroundthekneearetrospectiveanalysis