Cargando…

Radiation Dose to the Eye Lens through Radiological Imaging Procedures at the Surgical Workplace during Trauma Surgery

Background: Due to the drastic reduction of the eye lens dose limit from 150 mSv per year to 20 mSv per year since 2018, the prospective investigation of the estimated dose of the eye lens by radiological imaging procedures at the surgical site during trauma surgery in the daily work process was car...

Descripción completa

Detalles Bibliográficos
Autores principales: Apelmann, Christian, Kowald, Birgitt, Weinrich, Nils, Dischinger, Jens, Nienhaus, Albert, Seide, Klaus, Martens, Heiko, Jürgens, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6843242/
https://www.ncbi.nlm.nih.gov/pubmed/31614696
http://dx.doi.org/10.3390/ijerph16203850
_version_ 1783468168862236672
author Apelmann, Christian
Kowald, Birgitt
Weinrich, Nils
Dischinger, Jens
Nienhaus, Albert
Seide, Klaus
Martens, Heiko
Jürgens, Christian
author_facet Apelmann, Christian
Kowald, Birgitt
Weinrich, Nils
Dischinger, Jens
Nienhaus, Albert
Seide, Klaus
Martens, Heiko
Jürgens, Christian
author_sort Apelmann, Christian
collection PubMed
description Background: Due to the drastic reduction of the eye lens dose limit from 150 mSv per year to 20 mSv per year since 2018, the prospective investigation of the estimated dose of the eye lens by radiological imaging procedures at the surgical site during trauma surgery in the daily work process was carried out. This was also necessary because, as experience shows, with changes in surgical techniques, there are also changes in the use of radiological procedures, and thus an up-to-date inventory can provide valuable information for the assessment of occupationally induced radiation exposure of surgical personnel under the current conditions. Methods: The eye lens radiation exposure was measured over three months for five trauma surgeons, four hand surgeons and four surgical assistants with personalized LPS-TLD-TD 07 partial body dosimeters Hp (0.07). A reference dosimeter was deposited at the surgery changing room. The dosimeters were sent to the LPS (Landesanstalt für Personendosimetrie und Strahlenschutzausbildung) measuring institute (National Institute for Personal Dosimetry and Radiation Protection Training, Berlin) for evaluation after 3 months. The duration of the operation, occupation (assistant, surgeon, etc.), type of surgery (procedure, diagnosis), designation of the X-ray unit, total duration of radiation exposure per operation and dose area product per operation were recorded. Results: Both the evaluation of the dosimeters by the trauma surgeons and the evaluation of the dosimeters by the hand surgeons and the surgical assistants revealed no significant radiation exposure of the eye lens in comparison to the respective measured reference dosimeters. Conclusions: Despite the drastic reduction of the eye lens dose limit from 150 mSv per year to 20 mSv per year, the limit for orthopedic, trauma and hand surgery operations is well below the limit in this setting.
format Online
Article
Text
id pubmed-6843242
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-68432422019-11-25 Radiation Dose to the Eye Lens through Radiological Imaging Procedures at the Surgical Workplace during Trauma Surgery Apelmann, Christian Kowald, Birgitt Weinrich, Nils Dischinger, Jens Nienhaus, Albert Seide, Klaus Martens, Heiko Jürgens, Christian Int J Environ Res Public Health Article Background: Due to the drastic reduction of the eye lens dose limit from 150 mSv per year to 20 mSv per year since 2018, the prospective investigation of the estimated dose of the eye lens by radiological imaging procedures at the surgical site during trauma surgery in the daily work process was carried out. This was also necessary because, as experience shows, with changes in surgical techniques, there are also changes in the use of radiological procedures, and thus an up-to-date inventory can provide valuable information for the assessment of occupationally induced radiation exposure of surgical personnel under the current conditions. Methods: The eye lens radiation exposure was measured over three months for five trauma surgeons, four hand surgeons and four surgical assistants with personalized LPS-TLD-TD 07 partial body dosimeters Hp (0.07). A reference dosimeter was deposited at the surgery changing room. The dosimeters were sent to the LPS (Landesanstalt für Personendosimetrie und Strahlenschutzausbildung) measuring institute (National Institute for Personal Dosimetry and Radiation Protection Training, Berlin) for evaluation after 3 months. The duration of the operation, occupation (assistant, surgeon, etc.), type of surgery (procedure, diagnosis), designation of the X-ray unit, total duration of radiation exposure per operation and dose area product per operation were recorded. Results: Both the evaluation of the dosimeters by the trauma surgeons and the evaluation of the dosimeters by the hand surgeons and the surgical assistants revealed no significant radiation exposure of the eye lens in comparison to the respective measured reference dosimeters. Conclusions: Despite the drastic reduction of the eye lens dose limit from 150 mSv per year to 20 mSv per year, the limit for orthopedic, trauma and hand surgery operations is well below the limit in this setting. MDPI 2019-10-11 2019-10 /pmc/articles/PMC6843242/ /pubmed/31614696 http://dx.doi.org/10.3390/ijerph16203850 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Apelmann, Christian
Kowald, Birgitt
Weinrich, Nils
Dischinger, Jens
Nienhaus, Albert
Seide, Klaus
Martens, Heiko
Jürgens, Christian
Radiation Dose to the Eye Lens through Radiological Imaging Procedures at the Surgical Workplace during Trauma Surgery
title Radiation Dose to the Eye Lens through Radiological Imaging Procedures at the Surgical Workplace during Trauma Surgery
title_full Radiation Dose to the Eye Lens through Radiological Imaging Procedures at the Surgical Workplace during Trauma Surgery
title_fullStr Radiation Dose to the Eye Lens through Radiological Imaging Procedures at the Surgical Workplace during Trauma Surgery
title_full_unstemmed Radiation Dose to the Eye Lens through Radiological Imaging Procedures at the Surgical Workplace during Trauma Surgery
title_short Radiation Dose to the Eye Lens through Radiological Imaging Procedures at the Surgical Workplace during Trauma Surgery
title_sort radiation dose to the eye lens through radiological imaging procedures at the surgical workplace during trauma surgery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6843242/
https://www.ncbi.nlm.nih.gov/pubmed/31614696
http://dx.doi.org/10.3390/ijerph16203850
work_keys_str_mv AT apelmannchristian radiationdosetotheeyelensthroughradiologicalimagingproceduresatthesurgicalworkplaceduringtraumasurgery
AT kowaldbirgitt radiationdosetotheeyelensthroughradiologicalimagingproceduresatthesurgicalworkplaceduringtraumasurgery
AT weinrichnils radiationdosetotheeyelensthroughradiologicalimagingproceduresatthesurgicalworkplaceduringtraumasurgery
AT dischingerjens radiationdosetotheeyelensthroughradiologicalimagingproceduresatthesurgicalworkplaceduringtraumasurgery
AT nienhausalbert radiationdosetotheeyelensthroughradiologicalimagingproceduresatthesurgicalworkplaceduringtraumasurgery
AT seideklaus radiationdosetotheeyelensthroughradiologicalimagingproceduresatthesurgicalworkplaceduringtraumasurgery
AT martensheiko radiationdosetotheeyelensthroughradiologicalimagingproceduresatthesurgicalworkplaceduringtraumasurgery
AT jurgenschristian radiationdosetotheeyelensthroughradiologicalimagingproceduresatthesurgicalworkplaceduringtraumasurgery